Safety
Read and understand these instructions before beginning
installation. The unit should be installed by a competent person.
Location
Check there is space for the unit in your chosen location. The unit must not
affect the operation of open-flue appliances. Consult local regulations or a
qualified gas engineer.
The open sides of the diffuser must face a minimum 1m unobstructed path
away from any smoke detectors. If the diffuser cannot be repositioned,
up to two sides can be closed using the plastic blanking plates. In this
configuration the open sides must face a minimum 1.5m unobstructed
path away from any smoke detectors.
In properties with a floor above 4.5m steel diffusers must be fitted a
minimum of 1m away from the smoke detectors instead of the included
plastic diffusers.
Partition walls between buildings must be complete with any breaks
filled.
In properties with a floor more than 4.5m above ground level the unit must
be wired into a smoke alarm, the unit will switch off on detection of smoke
(see page 14 for wiring information).
The appliance is considered suitable for use in countries with a warm
damp equable climate, but may also be used in other countries.