) ROOM AIR CONDITIONER Owner's Manual ComfortStar ® T1W3-06CD(I) (242) T1W3-09CD(I) (239) T1W3-12CD(I) (23A) T1W3-18CD(I) (23B) IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Page 3
CONTENTS S AFET Y P R ECAUTION S ---------------------------------------------------------------------------------------------------------------------------------------------------------------- UN IT S P ECI Fl CA Tl O N S AND FEATU R E S -------------------------------------------------------------------------------------------------------------------- 0 P E R A Tl ON IN S T R U CTI O N S --------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------ CA R E AND MAI NTE NAN CE...
SAFETY PRECAUTIONS It is really important you read Safety Precautions Before Operation and Installation Incorrect installation due to ignoring instructions can cause serious damage or injury. The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION. Explanation of Symbols WARNING This symbol indicates the possibility of personal injury or loss of...
Page 5
ELECTRICAL WARNINGS • Only use the specified wire. If the wire is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. • The product must be properly grounded at the time of installation, or electric shock may occur.
Page 6
• LEAK DETECTI O N SYSTEM installed. Unit must be powered except for service. For the unit with refrigerant sensor, when the refrigerant sensor detects refrigerant leakage, the indoor unit will display an error code and emit a buzzing sound, the compressor of outdoor unit will immediately stop, and the indoor fan will start running.
Page 8
1. Installation (where refrigerant pipes are allowed) - Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
c. During the evacuation test, after achieving a vacuum level specified in the manual or less, the refrigeration system shall be isolated from the vacuum pump and the pressure shall not rise above 1500 microns within 10 min. The vacuum pressure level shall be specified in the manual, and shall be the lessor of 500 microns or the value required for compliance with national and local codes and standards, which may vary between residential, commercial, and industrial...
Page 10
6. No ignition sources No person carrying out work in relation to a REFRIGERATING SYSTEM which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space.
Page 11
12. Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Page 12
15. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed: Works shall be undertaken with appropriate tools only (In case of uncertainty, • please consult the manufacturer of the tools for use with flammable refrigerants) Ensure that contamination of different refrigerants does not occur when using •...
Page 13
for the recovered refrigerant and labelled for that refrigerant (i.e., special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of the flammable refrigerant.
UNIT SPECIFICATIONS AND FEATURES 9NOTE Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail. Unit Parts Air Intake Grille Air Filter Display Panel Air Vane Air Outlet Air Inlet Electronic...
OPERATION INSTRUCTIONS 9NOTE To further optimize the performance of your unit, do the following: • Keep doors and windows closed. • Limit energy usage by using TIMER ON and TIMER OFF functions. • Do not block air inlets or outlets. •...
Page 16
Refrigerant Leakage Detection Sleep Operation • When the system detects a malfunction of the The SLEEP function is used to decrease energy refrigerant, the indoor unit will automatically use while you sleep (and don't need the same display the following error codes: temperature settings to stay comfortable).
CARE AND MAINTENANCE & BEFORE CLEANING OR MAINTENANCE REMEMBER TO DISCONNECT THE POWER BEFORE CLEANING OR MAINTENANCE, EXCEPT FOR CLEANING AIR FILTER. TURN THE CURCUIT BREAKER OF THE INDOOR UNIT TO OFF IS NOT A KIND OF POWER DISCONNECTION. • Contact an authorized service technician for repair or maintenance. Improper repair and maintenance may cause water leakage, electrical shock, or fire, and may void your warranty.
Page 18
Model B & 1. Press the circular positon to open the two CAUTION screw covers, then remove the two screws. • Do not dry out the air filter under direct sunshine or with fire. • The air filter should be installed before the unit body installation.
Maintenance your AC. Maintenance - Maintenance - Long Periods of Non-Use Pre-Season Inspection If you plan not to use your air conditioner for After long periods of non-use, or before periods of an extended period of time, do the following: frequent use, do the following: 爸...
TROUBLESHOOTING 心 CAUTION If any of the following conditions occurs, turn off your unit immediately! • The power cord is damaged or abnormally warm • You smell a burning odor • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
Page 21
一 Possible Causes The outdoor unit The unit will make different sounds based on its current operating mode. makes noises Dust is emitted from Th e unit may accumulate dust d uring extended periods of non-use, which either the indoor or will be emitted when the unit is turned on.
Page 22
_ _ soIutlon Wait for the power to be restored Power failure The power is turned off Turn on the power The unit is not The fuse is burned out Replace the fuse working Replace batteries Remote control batteries are dead The Unit's 3-minutes protection Wait three minutes after restarting has been activated...
Page 24
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. QS002U-T2(B)-FKJ(R454B) 16122500A32773...