mmvdisk pdisk list --recovery-group {all | RgName[,RgName]} --replace
# mmvdisk pdisk list --recovery-group all --replace
recovery group
-----------------------------------
-------------------------------------------------------------
s6k_lothal_qa6_1_hs_lothal_qa6_2_hs
HoustonRack U20-23, Enclosure 5149-F48-78L0018 Drive 14
b) Prepare each of the physical disk name entries for replacement with the following command:
mmvdisk pdisk replace –-prepare –-recovery-group <rg name> --pdisk <pdisk name>
To prepare physical disk e2s11 of recovery group BB01L for replacement, run the following
command:
# mmvdisk pdisk replace --prepare --recovery-group BB01L --pdisk e2s11
mmvdisk: Suspending pdisk e2s11 of RG BB01L in location SX32901810-11.
mmvdisk: Location SX32901810-11 is Enclosure 2 Drive 11.
mmvdisk: Carrier released.
mmvdisk:
mmvdisk:
mmvdisk:
mmvdisk:
mmvdisk:
mmvdisk:
mmvdisk:
The drive that is associated with the physical disk name in the previous command must have the
amber LED on to indicate that it is safe to remove the drive.
3. Remove the faulty drive, which has its amber LED on.
a) To unlock the drive and release latch, press the touchpoint (blue triangle), as shown in the next
figure.
12  IBM Storage Scale System 6000: Service Guide
- Remove carrier.
- Replace disk in location SX32901810-11 with type '00W1240'.
- Reinsert carrier.
- Issue the following command:
mmvdisk pdisk replace --recovery-group BB01L --pdisk 'e2s11'
pdisk
priority
FRU (type)
-------
--------
---------------
e1s14
3.22
15.36TB NVMe Ti