AC EV CHARGER USER MANUAL MODEL: EV-B07-US009B We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us.
Page 2
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
Page 3
Warning-To reduce the risk of injury, user must read instructions manual carefully. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
SAFETY PRECAUTIONS Before installation, check that the grid is AC Level 2 “240 V ±10% (60 Hz)”. Otherwise it cannot be used. 2. Detection of the charging device has the function of user network circuit load capacity; When the electric grid circuit of the user cannot bear the charging power of the charging device, the device will automatically reduce the charging power and then charge the electric vehicle.
PRODUCT INTRODUCTION EV-B07-US009B series portable charger is designed for the pain points in the portable charging industry. It is characterized by convenient installation, use, and debugging, simple operation and maintenance, accurate measurement, and complete protection functions. It has good compatibility, and meets the charging requirements of national standard.
Page 6
QUIPMENT INSTRUCTIONS 2. After the device is powered on, it enters the standby state. The device standby interface is shown below: 2.1 After inserting the charging gun head into the vehicle charging port, the charging interface is shown below: 2.2 Adjust the charging current: click the button to adjust the charging gear:40A-20A-10A-5A-40A Cycle the current in this order.After switching the usage current, plug in the gun head to charge.
Page 7
OBILE PHONE APP CHARGING OPERATION INSTRUCTIONS 3. APP download and binding use a. To download the smart APP, enter the following address in the mobile browser: https://developer.tuya.com/cn/docs/iot/tuya-smart-app-smart-life-app-adva ntages?id=K989rqa49rluq Click the website and follow the prompts to install. b. Qr code download: Open the mobile browser or other social software, scan the QR code, and follow the APP according to the prompts.
Page 8
Press and hold on the charging panel again, and the display screen will display Plug and Charge to enter the Plug and Play charging mode. Open the Location, Bluetooth, and Wifi of the mobile phone. If the charging device is in standby state, the APP will automatically search for the charging device and the device name will be displayed.
Page 9
flashing" and "Fast flashing" as prompted. Enter the WIFI password (WIFI password connected to the mobile phone) and click Next to match the password, and always set the bound device as prompted. After binding the device, charge it according to the APP interface. e.
Page 10
Equipment The green and red lights flash every two seconds overtemperature 4.1 Fault display description(EV-B07-US009B) 4.2 Ground Fault: The ground wire is not connected or the ground wire is poor. 4.3 CP Fault:The device detects that the CP voltage exceeds 6V ± 0.8 or 9V ±...
Page 11
4.4 Overcurrent Fault: If the charging current of the device exceeds the threshold and continues to exceed 5s, the device will disconnect charging and report a fault, which cannot be automatically restored. 4.5 Undervoltage Fault: The rated input voltage is 240V, and a fault is reported if the voltage value is lower than 190V±5V.
INSTALLATION INSTRUCTIONS 5. List of Parts General purpose accessories Product specification Ac pile instruction manual 1 copy Storage bag Portable hard case travel bag 1 PCS Wall mount installation Wall mount Wall mounted fasteners 1 PCS Expansion screw M8*60 expansion screw 4 PCS Charging cable hook Iron hook...
Page 13
b.Select the installation location of the device. The lowest position of the equipment is a wall mounted fastener 1200 mm above the ground. b. Drill 2 holes with a diameter of 8mm according to the location of the fixed screw holes of Wall mounted fasteners, and tap in the expansion rubber plugs.
TROUBLESHOOTING GUIDANCE 1. Poor grounding alerts for faults. Failure manifestations:Red light flashes once in 2s and "Ground Fault" is displayed on the screen. Fault clearance: A. Check whether the socket is well grounded, and if not, do a good job of grounding.
Page 15
B. It is also possible to remove the charging cable, press the device "A" button for 5s, and then plug the charging cable into the electric car. 4. Charging is not possible and the red light flashes. Failure manifestations:The device is plugged in, the charging cable is connected to the electric car, the device flashes red and cannot be charged.