Summary of Contents for SunPower Maxeon SPR-MAX6 BLK Series
Page 1
SunPower Maxeon Performance Photovoltaic Panels Safety and Installation Instructions Europe, Asia, Australia, Latin America and Africa Available Languages: English French German Italian Spanish Polish Indonesian...
Page 2
In case of inconsistencies or conflicts between the English version and any other versions of this manual (or document), the English version shall prevail and take control in all respects. For the latest revision, please refer to www.sunpower.maxeon.com/int/PVInstallGuideIEC Contents of this manual are subject to change without notice. Maxeon Solar Technologies, Ltd.
Page 3
IEC certified Maxeon photovoltaic modules carrying www.sunpower.maxeon.com. Please read this document the TUV logo on the product label (Figure 1). for more information. Warranties do not apply to any of the following; PV Modules subjected to: (i) misuse, abuse, neglect or accident;...
Page 4
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD electrical hazards as well as laceration hazards. Contact The PV modules complies with Safety Class II standards, with damaged module surfaces or module frame can ensuring double or reinforced insulation to prevent electric cause electric shock.
Page 5
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD If you are doing a frame grounding connection, avoid minimal duration during peak production hours. Sources the direct contact between Aluminum and Copper using include interrow shading, regular soiling, snow, and site an intermediate metal like stainless steel or tin.
Page 6
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD No Maxeon module should be mounted at a site where it requirements of the National Construction Code and may be subject to direct contact with salt water, or other AS/NZS 5033.
Page 7
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD pressure clamps or clips where torque values are design, irradiance, albedo height module higher than otherwise stated. installation above ground and has an overall impact on the rear side irradiance mismatch. Minimum clamp width allowance is ≥35mm, and for The Rearside mismatch losses are proportional to the corner clamping the minimum clamp width is:...
Page 8
When a residential installation (with “RES” in the description) designed/planned using SunPower/Maxeon modules with different Part Numbers (SKU’s), in order to minimise cosmetic differences between modules, please ensure the anti-reflective supplier of the modules are identical. This can be done by referring to the product description, and looking for AR-XX, where “XX”...
Page 11
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD Appendix: Mounting Configurations and Load Ratings SunPower Maxeon 3 104 cells Commercial Solar Panel SPR-MAX3-XXX-COM (xxx = 340 - 400 in steps of 5) 400 mm 539 mm...
Page 12
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 3 104 cells Residen al Solar Panel SPR-MAX3-XXX, SPR-MAX3-XXX-BLK (xxx = 340 - 400 in steps of 5) 1100 mm 1300 mm 1500 mm 1690 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 13
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 3 112 cells AC Ready Solar Panel SPR-MAX3-XXX-R, SPR-MAX3-XXX-BLK-R, SPR-MAX3-XXX-COM-R (xxx = 400 - 430 in steps of 5) 1100 mm 1300 mm 1656 mm 1812 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 14
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 3 112 cells Residen al Solar Panel SPR-MAX3-XXX, SPR-MAX3-XXX-BLK (xxx = 415 - 430 in steps of 5) 1100 mm 1300 mm 1500 mm 1812 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 15
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 3 128 cells Solar Panel SPR-Xyy-XXX-COM (xxx = 420 - 485 in steps of 1) 300 mm 398 mm 400 mm 539 mm 1058 mm 1200 mm...
Page 16
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 6 66 cells Residen al Solar Panel SPR-MAX6-XXX (xxx = 410 - 445 in steps of 5) 1100 mm 1872 mm A - Ground Holes (4X Ø4.2mm) B- Moun ng Holes (4X Ø6.8mm)
Page 17
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 6 72 cells Commercial Solar Panel SPR-MAX6-xxx-COM (xxx = 435 - 475 in steps of 5) 400 mm 1200 mm 1423 mm 1653 mm 2047 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 18
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 7 112 cells Residen al Solar Panel SPR-MAX7-XXX-PT (xxx = 420 - 445 in steps of 5) 1100 mm 1300 mm 1787mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 19
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 7 104 cells Solar Panel SPR-MAX7-xxx, SPR-MAX7-xxx-BLK (xxx = 340 - 400 in steps of 5) 150 50 1100 mm 1471 mm 1661 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 20
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 7 120 cells Solar Panel SPR-MAX7-xxx, SPR-MAX7-xxx-BLK (xxx = 440 - 475 in steps of 5) 1100 mm 1723 mm 1913 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 21
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Maxeon 7 128 cells Solar Panel SPR-MAX7-XXX, SPR-MAX7-XXX-BLK (xxx = 480 - 505 in steps of 5) 1100 mm 1857 mm 2047 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 22
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 6 Bifacial Solar Panel SPR-P6-XXX-COM-M-BF (xxx = 510 - 555 in steps of 5) 1232.77 1088.77 646 546 1042 1042 400 mm 1100 mm 1400 mm 2384 mm Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
Page 23
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 6 Bifacial Solar Panel SPR-P6-XXX-COM-S-BF (xxx = 470 - 510 in steps of 5) 1100 mm 1400 mm 2185 mm Measurement Tolerances are +/-3mm for the Length and Width of the module.
Page 24
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 6 Residen al and Commercial Solar Panel (SPR-P6-XXX-BLK, SPR-P6-XXX-COM-XS) (xxx = 380 - 420 in steps of 5) 1100 mm 1808 mm A - Ground Holes (4X Ø 4.2mm) B - Moun ng Holes (4X 9mm (W) x 14mm (L), R4.5mm)
Page 25
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 6 Commercial Solar Panel SPR-P6-XXX-COM-XS (1092mm) (xxx = 380 - 420 in steps of 5) 1100 mm 1808 mm A - Ground Holes (4X Ø 4.2mm) B - Moun ng Holes (4X 9mm (W) x 14mm (L), R4.5mm)
Page 26
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance P7 COM-S Bifacial Solar Panel SPR-P7-XXX-COM-S (xxx = 520 - 560 in steps of 5) 1100 mm 1400 mm 2156 mm Measurement Tolerances are +/- 3mm for the Length and Width of the module.
Page 27
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 7 Residen al Solar Panel SPR-P7-XXX-BLK, SPR-P7-XXX-BLK-1500 (xxx = 427, 430 - 460 in steps of 5) 1100 mm 1790 mm A - Ground Holes (4X Ø 4.2mm) B - Moun ng Holes (4X 9mm (W) x 14mm (L), R4.5mm)
Page 28
MAXEON SOLAR TECHNOLOGIES LTD. Safety and Installation Instructions - Document 001-15497 Rev.AD SunPower Performance 7 Residen al Solar Panel SPR-P7-XXX-BLK-P (xxx = 485 - 520 in steps of 5) 1100 mm 1400 mm 1996 mm A - Ground Holes (4X Ø 4.2mm) B - Moun ng Holes (8X 4mm (W) x 14mm (L), R4.5mm)
Need help?
Do you have a question about the Maxeon SPR-MAX6 BLK Series and is the answer not in the manual?
Questions and answers