AMC16(L)-DETT DC power meter module of base station
Installation and operation manual V1.3
Acrel Co.,Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMC16-DETT and is the answer not in the manual?

Questions and answers

Summary of Contents for Acrel AMC16-DETT

  • Page 1 AMC16(L)-DETT DC power meter module of base station Installation and operation manual V1.3 Acrel Co.,Ltd.
  • Page 2 Declaration All rights reserved. Without the written permission of the company,the contents of any paragraphs and chapters in this manual shall not be copied,copied or reproduced or disseminated in any form. Otherwise,all consequences shall be borne by the violator. The company reserves all legal rights. The company reserves the right to modify the specifications described in this manual without prior notice.Before ordering,please consult your local agent for new specifications.
  • Page 3: Table Of Contents

    目录 1 Overview...............................1 2 Products model............................1 3 Technical parameters..........................1 4 Outline structure............................2 5 Installation wiring..........................3 5.1 terminals and wiring........................3 5.2 wiring precautions...........................3 6 Guide to use............................4 6.1 Panel diagram..........................4 6.2 LED instructions..........................4 6.3 AMC16L-DETT key operation.......................4 6.4 AMC16L-DETT operation display instructions................5 7 Communication guide..........................7 8 Hall densor recommended........................9...
  • Page 4: Overview

    1 Overview Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software.
  • Page 5: Outline Structure

    AMC16(L)-DETT DC power meter module of base station unit:mm 48VDC IN Analog IN VDC Output RS485 AUX IN 10 11 61 62 37 38 39 30 31 Acrel 6 Channel DC Energy Meter Comm Acrel Co.,Ltd 9 14 15 16 17 18 19...
  • Page 6: Installation Wiring

    2. Current input should use external diverter or hall sensor. 3. To ensure the accuracy,the DC meter should used together with Acrel hall sensors, the wiring length between sensors to meters should <3m. 4. Advise use three core shielded wires as communication connection wires. Each core >0.5mm...
  • Page 7: Guide To Use

    6 Guide to use 6.1 Panel diagram Acrel 6 Channel DC Energy Meter Comm Acrel Co.,Ltd AMC16-DETT AMC16L-DETT AMC16L-DETT 6.2 LED instructions A total of 8 LED indicators are used to indicate the working status of the metering modules; “running”status(green):when the metering module is in mormal operation,the running indicator light flashes。...
  • Page 8: Amc16L-Dett Operation Display Instructions

    : 0.00 The DC energy metering module of AMC16-DETT and AMC16L-DETT base stations has six metering branches.By default,the first channel is the total metering,the second,third and fourth channels are mobile users,unicom users and telecom users respectively,and the fifth and sixth channels are reserved.
  • Page 9 1 、 communication 2 、 time password:000 password:000 4 、 system 3 、 electric energy MENU MENU I1 I2 I3 I4 I5 I6 whether save the settings? voltage:0.76 current:0.00 1 、 communication 1 、 MODBUS communication check digit NONE address 2 、...
  • Page 10: Communication Guide

    7 Communication guide Modbus address table Telemetry,telecontrol Pamameter area(0x00H~0x2FH) Serial variable address Read/ length unit Data type note number write address NONE Uint16 1~247 Baud rate NONE Uint16 2400,4800,9600,19200 reserve NONE Uint16 reserve NONE Uint16 voltage ratio NONE Uint16 voltage ratio 1 NONE Uint16 Current ratio 2...
  • Page 11 Electric parameter data area(0x30H~0xEFH) Serial variable address Read/write length unit Data type note number voltage 1 30H-31H float voltage 2 32H-33H float voltage 3 34H-35H float voltage 4 36H-37H float voltage 5 38H-39H float voltage 6 3AH-3BH float current 1 3CH-3DH float current 2...
  • Page 12: Hall Densor Recommended

    8 Hall densor recommended Recommend hall sensor (unit:mm) GIN OFS AHKC-EKA(50A/5V) apertureΦ20mm OFS GIN AHKC-EKB(100A/5V) apertureΦ40mm AHKC-K(200A/5V) apertureΦ64*16mm...
  • Page 13 Address: No.253 Yulv Road Jiading District,Shanghai,China TEL.: 0086-21-69158338 0086-21-69156052 0086-21-59156392 0086-21-69156971 Fax: 0086-21-69158303 Web-site: www.acrel-electric.com E-mail: ACREL008@vip.163.com Postcode: 201801 Manufacturer: Jiangsu Acrel Electrical Manufacturing Co.,LTD. Address: No.5 Dongmeng Road,Dongmeng industrial Park,Nanzha Street,Jiangyin City,Jiangsu Province,China TEL./Fax: 0086-510-86179970 Web-site: www.jsacrel.com Postcode: 214405 E-mail: JY-ACREL001@vip.163.com...