MOD : DS18/A7-P9P
Production code : CV180PSVGD110BH
04/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS18/A7-P9P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Diamond DS18/A7-P9P

  • Page 1 MOD : DS18/A7-P9P Production code : CV180PSVGD110BH 04/2024...
  • Page 2 Te c h n i c a l i n s t r u c t i o n s SELF-SERVICE DISPLAY...
  • Page 4 I N D E X OPERATION MANUAL INSTRUCTIONS A good knowledge of the features of this product will make its use safer and che- FOR USE & MAINTENANCE aper. REFRIGERATED WALL-CABINETS...
  • Page 5 - to expose the equipment to the atmospheric agents (sun, snow, rain, etc.); - to wash the equipment with water jets; - to allow children to use the equipment without adult supervision and make sure that they do not play with the equipment;...
  • Page 6: Handling And Transport

    maintenance personnel and generally to all the pe- 4. UNPACKING ople that for different reasons have to operate with the equipment. The packing materials can be recycled, therefore they must not be dispersed, but they have to be disposed in It is forbidden to remove, edit or otherwise modify the special waste plan for recycling.
  • Page 7: Installation

    the exchange of air in the environment even when the room is closed: Max. allowed ambient R.H. Max allowed relative temperature humidity +25°C During the installation procedure, it is prohibited to: In case the ambient conditions are not included in - Tilt the cabinet, as the lubricating oil contained in the above mentioned ones, a lower performance the cabinet itself could enter the cold circuit and the...
  • Page 8: Electrical Power/Connection

    10. ASSEMBLING - To pull the electrical cable or the unit to unplug the equipment from the socket (fig. A). - To use extension sockets, worn down cables, cables The equipment has to be completed with the assembling with damaged or fissured insulation as they are very of the shelves and for some models also of the glasses dangerous: they could cause sparks, electric shock that have to...
  • Page 9 the proper temperature for the products that have to be 17. DEFROSTING displayed. It will take approx. 3 hours for the cabinet to reach the proper temperature. The products to be The defrosting takes place automatically during the run- displayed will have to be already cold according to the ning of the unit.
  • Page 10: Emergency Situations

    be used during the closing time of the shop or in case of suspension of the power supply (due to any cause). The night-blind keeps the cold air inside the wall-cabinet and so it helps to reduce the cold dispersion and to save energy.
  • Page 11 Keep the counter away from free fl ames or sources of ignition. IN CASE OF DAMAGE Keep the counter away from free fl ames or sources of ignition Thoroughly ventilate the area for a few minutes. Swi- tch off the counter and disconnect the power plug. Contact customer service.
  • Page 12 Electrical diagram 1 2 3 4 5 6 A - PLUG B - FILTER C - MAGNETOTHERMAL SWITCH D - UNIT THERMOSTAT E - WITH UNIT F - LIGHT G - ELECTRIC TANK RESISTANCE H - EVAPORATOR FAN...