Download Print this page
Yaesu FTM-200DR Firmware Update Instruction Manual
Yaesu FTM-200DR Firmware Update Instruction Manual

Yaesu FTM-200DR Firmware Update Instruction Manual

Hide thumbs Also See for FTM-200DR:

Advertisement

Quick Links

FTM-200DR/DE
Main Firmware
Update Instruction Manual
YAESU MUSEN CO., LTD.

Advertisement

loading
Need help?

Need help?

Do you have a question about the FTM-200DR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Yaesu FTM-200DR

  • Page 1 FTM-200DR/DE Main Firmware Update Instruction Manual YAESU MUSEN CO., LTD.
  • Page 2: Important Notes

    Writing incorrect firmware to the transceiver may cause abnormal operation or failure. Important Notes • All responsibility for the use of this software lies with the customer. Yaesu cannot be held responsible in any way for any damages or losses, which may be incurred by the customer as a result of using this software.
  • Page 3 System Requirements (Operating Environment) To use this program, a personal computer (PC) with one of the following Windows operating systems, and a USB data connection cable are required Supported Operating Systems One of the following operating system environments: ® ® •...
  • Page 4: Displaying The Firmware Version

    DSP Ver. : X.XX (1) Preparing Microsoft .NET Framework 3.5 Service Pack 1 For the FTM-200DR/DE firmware update, Microsoft .NET Framework 3.5 Service Pack 1 is required. According to the Windows version you use, follow the procedure below. * The following procedure must be performed only when using the firmware update tool for the first time.
  • Page 5 4. Click the [Close] button.
  • Page 6 (2) Installing a USB Driver and Microsoft Visual C++ 2008 Redistributable Start the “YAESU Firmware Update Program” to install a USB driver. After the USB driver installation completes, install “Microsoft Visual C++ 2008 Redistributable”. * The following procedure must be performed only when using installation application for the first time.
  • Page 7 The USB driver will be installed, and the “USB Drive Loading…” display will blink on the “Driver Install” screen. * If the “Windows Security” screen appears, click the [Install] button. After a while, the “Microsoft Visual C++ 2008 Redistributable Setup” screen appears. 5.
  • Page 8 Microsoft Visual C++ 2008 Redistributable will be installed. When the installation completes, “Setup Complete” appears on the “Microsoft Visual C++ 2008 Redistributable Setup” screen. 7. Click the [Finish] button. Returns to the “Driver Install” screen of the YAESU Firmware Update Program.
  • Page 9 8. When the power of FTM-200DR/DE is ON, press and hold the [POWER] switch to turn it OFF. 9. Disconnect the DC power cable from the transceiver. 10. Move the “firmware update” switch to the right, into the MAIN firmware writing mode, and then connect the FTM-200DR/DE to the PC with the supplied USB cable.
  • Page 10 Device Manager, the PC will incorrectly recognize the driver. Refer to the instructions “(2) Installing a USB Driver and Microsoft Visual C++ 2008 Redistributable” (Page 6)“, to install the correct driver “Generic Boot USB Direct”. Returns to the “YAESU Firmware Update Program” screen.
  • Page 11 15. Click the [Update] button. 16. To update the main firmware, proceed to step 8 (page 14) of “(3) Updating the Main Firmware”.
  • Page 12: Updating The Main Firmware

    (3) Updating the Main Firmware Caution After updating the Main firmware, reset-all will be executed for FTM-200DR/DE. The reset will delete all saved data. Be sure to back up your registered memory channel data using a microSD memory card or write it down. For details on “Saving/Loading Memory Channel Information to/from microSD Memory Card”, refer to the “FTM-200DR/DE Advance Manual”.
  • Page 13 3. When the power of FTM-200DR/DE is ON, press and hold the [POWER] switch to turn it OFF. 4. Disconnect the DC power cable from the transceiver. 5. Move the Firmware update switch to the right to the MAIN firmware writing mode, and then connect the FTM-200DR/DE to the PC with the supplied USB cable.
  • Page 14 The “Select USB Device” screen appears. 9. Click the [OK] button. The firmware transfer starts and the FTM-200DR/DE MAIN firmware update executes (it takes about 10 seconds to complete the update). When the MAIN firmware update completes, a message appears.
  • Page 15 The post-update procedure appears. Follow the on-screen the post-update procedure. 11. Disconnect the DC power cable from the transceiver. 12. Disconnect the USB cable from the DATA jack and the PC. DATA Jack 13. Use a pointed object such as a pin to change the “firmware update” switch position to “normal operation mode (left)”.
  • Page 16 19. Press the DIAL knob to reset all. 20. Press and hold the [POWER] switch to turn the power OFF. 21. Click the [OK] button on the “YAESU Firmware Update Program” screen. Returns to the YAESU Firmware Update Program startup screen.
  • Page 17 Copyright 2022 YAESU MUSEN CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of YAESU MUSEN CO., LTD. YAESU MUSEN CO., LTD. Tennozu Parkside Building 2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo 140-0002 Japan YAESU USA 6125 Phyllis Drive, Cypress, CA 90630, U.S.A.

This manual is also suitable for:

Ftm-200de