MQ Power WHISPERWATT DCA150SSJU4F3 Quick Start Manual

60 hz generators (isuzu br-4jj1x/br-4hk1x diesel engines)
Hide thumbs Also See for WHISPERWATT DCA150SSJU4F3:

Advertisement

QUICK START GUIDE
WHISPERWATT™ SERIES
MODELS
DCA150SSJU4F3
DCA180SSJU4F3
DCA220SSJU4F3
60 Hz GENERATORS
(ISUZU BR-4JJ1X/BR-4HK1X DIESEL ENGINES)
Revision #0 (03/11/25)
To find the latest revision of this publication
or associated literature, visit our website at:
www.mqpower.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WHISPERWATT DCA150SSJU4F3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MQ Power WHISPERWATT DCA150SSJU4F3

  • Page 1 QUICK START GUIDE WHISPERWATT™ SERIES MODELS DCA150SSJU4F3 DCA180SSJU4F3 DCA220SSJU4F3 60 Hz GENERATORS (ISUZU BR-4JJ1X/BR-4HK1X DIESEL ENGINES) Revision #0 (03/11/25) To find the latest revision of this publication or associated literature, visit our website at: www.mqpower.com...
  • Page 2: Generator Start - Up Procedure ( Manual )

    GENERATOR START - UP PROCEDURE ( MANUAL ) BEFORE STARTING WARNING CAUTION DO NOT operate this equipment without first reading and understanding all relevant safety information. Refer The engine’s exhaust contains harmful emissions. to the Safety Information section in the operation ALWAYS have adequate ventilation when operating.
  • Page 3 GENERATOR START - UP PROCEDURE ( MANUAL ) 3. Connect the load to the receptacles, output terminal 4. Close all engine enclosure doors (Figure 3). lugs, or optional cam-loks as shown in Figure 2. These load connection points can be found on the output terminal panel and the output terminal panel’s hard wire hookup panel.
  • Page 4 GENERATOR START - UP PROCEDURE ( MANUAL ) 4. After the warmup process has completed, place the 8. The ammeter (Figure 10) will indicate zero amps with Engine Speed switch in the HIGH (up) position. The no load applied. When a load is applied, the ammeter engine speed will increase to 1,800 rpm and the unit is will indicate the amount of current that the load is now ready for operation.
  • Page 5 GENERATOR START - UP PROCEDURE ( MANUAL ) 12. Place the main, auxiliary, and GFCI circuit breakers in the ON position (Figure 12). GFCI AUXILIARY CIRCUIT CIRCUIT BREAKERS BREAKERS MAIN CIRCUIT BREAKER Figure 12. Main, Auxiliary, And GFCI Circuit Breakers (ON) 13.
  • Page 6: Generator Start - Up Procedure ( Auto Mode )

    GENERATOR START - UP PROCEDURE ( AUTO MODE ) STARTING (AUTO MODE) 1. Perform steps 1–4 under Before Starting in the Generator Start-Up Procedure (Manual) section. DANGER 2. Place the Engine Speed switch in the HIGH position Before connecting this generator to any (Figure 15).
  • Page 7: Generator Shutdown Procedure

    GENERATOR SHUTDOWN PROCEDURE NORMAL SHUTDOWN PROCEDURE EMERGENCY SHUTDOWN PROCEDURE WARNING NOTICE NEVER stop the engine suddenly except in an The Emergency Stop switch should only be used emergency. to stop the engine in case of an emergency or to lock out operation during service.
  • Page 8: Here's How To Get Help

    © COPYRIGHT 2025, MULTIQUIP INC. Multiquip Inc ., the MQ logo and the MQ Power logo are registered trademarks of Multiquip Inc. and may not be used, reproduced, or altered without written permission. All other trademarks are the property of their respective owners and used with permission.