Force 250N – Maximum stroke 300 mm
Electrical feeding 110-230V~ 50/60Hz and 24V
NEKOS S.r.l. - Via Capitoni, 7/5 - 36064 Colceresa – VI – ITALY
+39 0424 411011 –  +39 0424 411013 - www.nekos.it - info@nekos.it
4420001.1 - Rev 20220628
USER INSTRUCTIONS
CAUTION. Carefully observe all the following installation instructions to
ensure personal safety.
The device is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lacking experience and knowledge. Do
not allow children to play with the fixed controls and keep any remote-control units
out of their reach.
Have installation checks performed periodically by qualified personnel from a service
centre authorised by the manufacturer. Do not use if repair or adjustment is required.
CAUTION. If the power cable is damaged, it must be replaced by qualified
personnel from a service centre authorised by the manufacturer.
CAUTION. Disconnect the power supply during cleaning or maintenance
operations. Do not use solvents or jets of water to wash the appliance; the
appliance should not be submerged in water.
In the event of fault or malfunction, switch off the device at the main switch. All repairs
and adjustments (e.g. setting the stroke) must only be performed by qualified
personnel from a service centre authorised by the manufacturer.
Always request exclusive use of original spare parts. Failure to respect this condition
could compromise safety and invalidate the benefits contained in the warranty for
the appliance. In the event of any problems or queries, consult your agent or contact
the manufacturer directly.
The A-weighted sound pressure level is less than 70dB(A).
Carefully preserve these instructions after installation.
Symbols used in the manual
This indication draw the attention about potential dangers for safety
DANGER
and health of peoples and animals
nekos products have been manufactured in accordance with safety standards and
conforms to the stipulations of current standards in force.
When correctly assembled, installed and used according to the present instructions, they
will not generate any danger for persons, animals or items.
.
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the K-ECO S3 230V and is the answer not in the manual?

Questions and answers

Summary of Contents for nekos K-ECO S3 230V

  • Page 1 When correctly assembled, installed and used according to the present instructions, they will not generate any danger for persons, animals or items. NEKOS S.r.l. - Via Capitoni, 7/5 - 36064 Colceresa – VI – ITALY +39 0424 411011 –  +39 0424 411013 - www.nekos.it - info@nekos.it...
  • Page 2: Table Of Contents

    PERSONAL SAFETY MPROPER INSTALLATION CAN SERIOUSLY ENDANGER SAFETY MANDATORY RISK ANALYSIS AND PROTECTION MEASURES The Nekos electrical actuators comply with the Machinery Directive (2006/42/EC), Standard Contents IEC 60335-2-103 (Particular requirements for drives for gates, doors and windows) and other directives and regulations indicated in the attached Declarations of Incorporation and 1.
  • Page 3: Technical Information About Function

    3.1. Calculation of opening / closure force The chain actuator K-ECO S3 Syncro is equipped with the NEKOS patented system Using the formulas on this page, approximate calculations can be made for the force required which enables the coordinated synchronization of the chain movement.
  • Page 4: Construction And Standards

    5. CONSTRUCTION AND STANDARDS 6. TECHNICAL DATA 230V INTENDED USE. The chain actuator has been designed and manufactured to K-ECO S3 230V Model SYNCRO SYNCRO open and close top hung windows opening outwards, bottom hung windows Force exerted by thrust and traction opening inwards, dormer windows, light domes and skylights.
  • Page 5: Electrical Power Supply

    SYNCRO³ models (see also chart at page 12): properly and are well balanced (where applicable). A. K-ECO S3 230V: runs on grid tension of 230V~ 50/60Hz, with a three wire cable . Check that the electrical supply used corresponds to the indications on TTENTION , common neutral;...
  • Page 6: Bottom Hung, Inward, Mounting Scheme

    Formula: Legend: Cable Number Communication Tension Feeder wires length of wires wires The two side dimensions - LA : (PA x 2) = QL LA = Window Sash Width (hinges side) PA = Actuator Attachment Points The central dimensions - QL x 2 IGHT BLUE QL = Side Dimensions 110-230V~ 50/60Hz...
  • Page 7: Electrical Connection With K-Lock Electromechanical Lock

    This procedure, known as “OVERLAP ACQUISITION” (paragraph 12.2), occurs the first IMPORTANT: in K-ECO S3 SYNCRO (230V and 24V) and K-ECO S3 24V actuators, time the actuator closes the window completely following a RESET operation and remains wire G “3” if not used must be insulated. REEN stored as an operating parameter.
  • Page 8: Overlap Acquisition Operation

    BLUE LED completely. In fully automatic mode, an opening manoeuvre of about 5 cm will follow. K-ECO S3 230V and their relative error meaning. During this phase make sure that there are no obstacles to the movement of the chain In case of a problem during installation or operation of the machines, consult the possible and wait for the completion of the procedure on all the actuators.
  • Page 9 In case of a problem during installation or operation of the machines, consult the possible 12.5. K-ECO S3 230V SYNCRO and 24V SYNCRO LED light signals causes listed below: Below the tables showing the flash indications provided by the LED installed on the...
  • Page 10: Checking For Correct Assembly

    1490 of the Civil Code. failure, or for normal maintenance or cleaning of the external surface of the window frame, the NEKOS patent allows rapid unhooking of the The guarantee covers products and individual parts for 2 years from the date of purchase.
  • Page 11: Dichiarazione Di Incorporazione

    Product Designation: Window chain drive Modello: 230 V : K-ECO S3 230V – K-ECO S3 230V SYNCRO Type : 24 V : K-ECO S3 24V – K-ECO S3 24V SYNCRO Anno di costruzione dal / Year of manufacturing from: 2020 Soddisfano gli applicabili requisiti essenziali della Direttiva Macchine 2006/42/EC, Allegato I Fulfil the essential requirements of the Machinery Directive 2006/42/EC, Annex I, Art.
  • Page 12 Notes NEKOS S.r.l. - Via Capitoni, 7/5 36064 Colceresa – VI – ITALY +39 0424 411011 –  +39 0424 411013 www.nekos.it info@nekos.it...