5.1 Overview........................24 1.1 Overview 5.2 APP Download ......................24 This manual is intended to introduce the SPM 3000-6000TL-HU Inverters manufactured by Shenzhen 5.3 APP Introduction......................25 GrowattNew Energy Co,Ltd. (hereinafter referred to as Growatt) in terms of the installation, operation, 6 Operation ..........................32 commissioning, maintenance and troubleshooting.
2 Production Introduction a. Make all electrical connections (e.g. conductor termination, fuses, PE, connection, etc.) in accordance with prevailing regulations. When working with the inverter 2.1 Product Overview powered on, adhere to all prevailing safety regulations to minimize risk of accidents. b.
Function Port Definition Product Size G-valve G-start CT-L TEMP TEMP (1,2): Battery temperature sensor for lead acid battery. CT-L (3,4): Current transformer (CT) for “Zero Export Limit” mode clamps on L when in single phase system. G-start (5,6): Generator start signal should be connected to the AC CON board CN9 terminal 5/6 position, G-start nominal open circuit.
Item Description requirements. Hybrid inverter This inverter can power all kinds of appliances in home or office environment, including motor type Grid-Hybrid Inverter SPM 3000-6000TL-HU User manual appliances such as refrigerator and air conditioner. Warranty Card L-type Hexagon wrench 044.SK0019400 Version: 1.0...
In some applications, switching devices may not be required but over-current protectors are still required. Model Wire Size SPM 3000-6000TL-HU 2 AWG or 4 AWG All wiring must be performed by a professional person. Connecting the battery with a suitable cable is important for safe and efficient operation of the system.
Terminate the AC conductors to the appropriate terminal, and then tighten the screws. Model Wire Size SPM 3000-6000TL-HU 10 AWG To avoid any malfunction, do not connect any PV modules with possible current leakage to the inverter. For example, grounded PV modules will cause current...
3.7 Earth Connection Ground cable shall be connected to ground plate on grid side this prevents electric shock, if the original protective conductor fails. Model Wire Size SPM 3000-6000TL-HU 12 AWG Make sure the inverter metal housing is grounded. Ground (yellow-green) ø...
Breakers selection recommendation for both DC and AC. Inverter Model SPM 3000-6000TL-HU PV Breakers(①) 600V/30A Battery Breaker(②) 80V/200A Generator Breaker(③) 400V/50A Load Breaker(④) 400V/50A AC Breaker(⑤) 400V/50A AC Breaker(⑥) 400V/50A On-Grid Home Load Breaker(⑦) 400V/50A 3.9 Single Phase 230Vac Parallel Connection Inverter NO.1...
Communication Connection Parallel Parallel Parallel Modbus SN: This feature is currently not being used. The status of the first and the end inverter switch needs to be fully turned on. CT: Connect pins 3 and 4 of L (Inverter NO.1). Allow for 6 machines to be combined.
Communication Connection Parallel Parallel Parallel Modbus SN: This feature is currently not being used. The status of the first and the end inverter switch needs to be fully turned on. CT: Connect pins 3 and 4 of L (Inverter NO.1). Allow for 6 machines to be combined.
4.3 Login Start the APP. Parallel Parallel Parallel Parallel Parallel Parallel -Choose the end user or O&M account. -Enter the account and password and log in. End user password is oss + current date.(example April 16, 2024 is oss20240416). -After login successfully, you can check the "Installation Manual". Modbus SN: This feature is currently not being used.
4.4 Direct WiFi/Bluetooth Commissioning Tool 4.5 Commissioning of SPM 3000-6000TL-HU -Select the “Direct WiFi/Bluetooth” channel. Local Commissioning> Quick Setting> Network Type -Select the corresponding model. -Select/fill network, enter the password, and select the server address. -Scan the device serial number barcode on the right side of the inverter to configure Bluetooth. You can -Choose the network configuration method-WiFi.
After the PV or Power Grid side of the SPM 3000-6000TL-HU is energized, the APP can connect to the inverter in either of the following ways: 1.The mobile phone is directly connected to the Bluetooth inside the SPM 3000-6000TL-HU for local tools. 5.3 APP Introduction 5.3.1 Multiple Languages Supported...
Page 16
5.3.4 Add power station and collector 5.3.6 Details and parameter settings in the power station -If you need to add, view, delete the datalogger or add a plant, please click the “+”in the upper right corner. -Create a power station after logging in to the homepage Note: If the datalogger needs to change the account monitoring, you need to delete the datalogger under (Note: Items marked * are required.
Page 17
- Click "!" to quickly view the current working data of the inverter (Solar voltage/Battery voltage/ -In the My device list at the bottom of the interface, you can view the status (signal strength, refresh Grid voltage/Grid frequency/Output voltage/Output frequency). time, etc.) of all collectors added to the power station.
Page 18
Set the maximum charging current, maximum discharge current, inversion time, grid voltage upper limit, grid voltage Lower limit etc. The password is: growatt + current date.(Notice: Do not change parameters at will as this may cause your inverter to malfunction.) -In the log at the bottom of the interface, you can view the device's historical fault records and fault Device editing page: Users can edit device aliases and delete devices.
6 Operation 7 Main Screen 7.1 Touch Screen Operation Flow Chart 6.1 Power ON/OFF Once the unit has been properly installed and the batteries are connected well, simply press On/Off button(located on the left side of the case) to turn on the unit. When one of the grid or PV is connected the screen will still light up even if the battery is not connected, in this condition, the system can still work normally when switch on the ON/OFF button and select no battery mode.
Page 20
7.2 Main Screen PV Detail Page SPM 6000TL-HU 298.3 298.6 1.2kW 17.2 Solar Panel Generation. 6.0kW Smart Power,Voltage,Current for each MPPT. Icon Description Solar panel energy for Day and Total. Grid Detail Page Battery: Battery Power, Inverter Generator Setting Menu Grid: Grid Power ,Export(negative), Load By clicking on the Grid icon, you can access the grid details screen.
Inverter Generation Power and Frequency.Voltage, Current, Power for each phase. AC-Temp: Temperature of AC module. DC-Temp: Temperature of DC-DC module. TX-Temp: Temperature of Transformer center. Generator Detail Page The image on the left shows the display screen when using voltage to measure the remaining power of the battery and make settings.
7.4 Basic Settings Max Charge/Discharge: Set the max charge/discharge rate for the batteries. No Battery: Tick this item if no battery is connected to the system. Revive Battery: If lithium battery is used but the inverter and the battery are incompatible in communication, please enable the Revive Battery function to wake up the battery.
LBCI: Low Battery Cut In. The inverter AC output will resume if actual battery capacity reaches General description: this value. The default value is 30%. The minimum value can be set is 29%. The set value must a. The inverter will measure all power from the “GRID” terminal as sell power. match LBCO<LBCO alarm<LBCI, otherwise the setting will not be successful.
Page 24
Grid Peak Shaving: when it is selected, grid output power will be limited within the set value. If the load power exceeds the allowed value, it will take PV energy and battery as supplement, if still can't meet the load requirement, grid power will increase to meet the load needs. Under this working condition, only “Load First”...
For example: During 09:00-18:00, when battery SOC is lower than 80% it will use grid to charge the Q(V):It adjusts the inverter reactive power according to the set grid voltage. This function adjusts battery until battery SOC reaches 80%. inverter output (active and reactive) power when grid voltage changes. During 18:00-09:00, when battery SOC is higher than 80%,hybrid inverter will discharge the battery FW: This series inverter is able to adjust inverter output power according to grid frequency.
7.8 Generator Settings ON Grid Always On: Using this mode, the Smart Load is always on. If ON Grid Always On is no setting, when battery SOC reaches 60%, Smart Load is on until SOC is lower than 30%. 7.10 Advanced Functions 6000 51.0 Auto N-PE short circuit...
7.11 Device Info. 8 Information and Processing Error codes are divided into Warning codes and fault codes. Warning codes identify the current statues of the inverter(Max), it does not affect the normal running of RCS06SKCSS the inverter. When a numeric warning appears on the Main Screen, it can usually be cleared through SK177.00-12171 SK176.00-12121 orderly shutdown/re-set or self-corrective action performed by the inverter.
Page 28
Auditing Error Auditing Error Description Solutions Description Solutions routine Code routine Code RSD Stop Press 1.Check if the emergency stop button is pressed. RSD Check Fault Alarm 2.If alarm message still exists, contact manufacturer. About 1.Restart the inverter. inverter 2.If the fault persists, contact the manufacturer. M3 Update Alarm Version Different 1.Output is short circuit.
9 Data Sheet Auditing Error Description Solutions Model routine Code 6000TL-HU 5500TL-HU 5000TL-HU 4600TL-HU 4000TL-HU 3600TL-HU 3000TL-HU 1.After shutting down the inverter, check if the grid power PV Input Data Grid Different supply cables are correctly connected. 2.If the warn persists, contact the manufacturer. 1.After disconnecting the grid power supply from the Recommen 9000W...
Page 30
AXE 5.0L-C1 current GROWATT AC short- RS485 circuit HOPE 5.5L-A1 PV Input Lightning For other compatible batteries, please refer to the official website of Growatt. Anti- islanding Insulation Resistance Residual Current Surge DC Type II / AC Type II Protection Certifications and Standards...
Growatt phase parallel 13 Appendix IV Meter installation recommendation Meter type Property Recommendation system 3-6PCS three-phase TPM-CT-E_EU(250A CT) Purchase from Growatt parallel systems Single-phase parallel SPM -CT -E(100A) Purchase from Growatt systems 2PCS single-phase SPM -CT -E(200A) Purchase from Growatt...