If You Are Using Windows Server 2008 Core Version; If You Are Using Linux Server - Dell PowerVault 3000i System Installation Manual

Modular disk system
Table of Contents

Advertisement

8 Click OK.
If discovery session failover is desired, repeat step 5 and step 6 (in this step) for all iSCSI ports on the
storage array. Otherwise, single-host port configuration is sufficient.
NOTE:
If the connection fails, make sure that all IP addresses are entered correctly. Mistyped IP addresses
are a common cause of connection problems.

If you are using Windows Server 2008 Core Version

1 Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
2 Start the iSCSI service (if necessary):
sc start msiscsi
3 If you are not using mutual CHAP authentication, skip to step 4.
4 Enter the mutual CHAP secret you entered for the storage array:
iscsicli CHAPSecret < secret >
5 Remove the target portal that you configured on the storage array during target discovery:
iscsicli RemoveTargetPortal < IP_address > < TCP_listening_port >
You will reset this IP address under CHAP authentication in the following steps.
6 Add the target portal with CHAP defined:
iscsicli QAddTargetPortal
< IP_address_of_iSCSI_port_on_storage_array > [ CHAP_username ]
[ CHAP_password ]
where
[ CHAP_username ] is the initiator name
[ CHAP_password ] is the target CHAP secret
If discovery session failover is desired, repeat step 5 for all iSCSI ports on the storage array. Otherwise,
single-host port configuration is sufficient.

If you are using Linux Server

1 Edit the /etc/iscsi.conf file to add an OutgoingUsername= and OutgoingPassword= entry
after each DiscoveryAddress= entry. OutgoingUsername is the iSCSI initiator name entered
in Step 4: Configure Host Access, and the OutgoingPassword is the CHAP secret created in Step
5: Configure CHAP Authentication on the Storage Array (optional).
For example, your edited /etc/iscsi.conf file might look like this:
DiscoveryAddress=172.168.10.6
OutgoingUsername=iqn.1987-05.com.cisco:01.742b2d31b3e
50