Table of Contents

Advertisement

Quick Links

E7 Series Electric Furnace
INSTALLATION INSTRUCTIONS
Downflow & Upflow Models
E7EM MULTI-POISE
WARNING
ELECTRICAL SHOCK, FIRE OR
EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
• Before servicing, disconnect all electrical
power to furnace.
• When servicing controls, label all wires prior
to disconnecting. Reconnect wires correctly.
• Verify proper operation after servicing.
DO NOT DESTROY. PLEASE READ CAREFULLY &
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
E7EU UPFLOW
It is your responsibility to know this product better than your customer.
This includes being able to install the product according to strict safety
guidelines and instructing the customer on how to operate and maintain
the equipment for the life of the product. Safety should always be the
deciding factor when installing this product and using common sense
plays an important role as well. Pay attention to all safety warnings and
any other special notes highlighted in the manual. Improper installation
of the furnace or failure to follow safety warnings could result in serious
injury, death, or property damage.
These instructions are primarily intended to assist qualified individuals
experienced in the proper installation of this appliance. Some local
codes require licensed installation/service personnel for this type of
equipment. Please read all instructions carefully before starting the
installation. Return these instructions to the customer's package for
future reference.
E7ED DOWNFLOW
ATTENTION INSTALLERS:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E7 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nortek E7 Series

  • Page 1 E7 Series Electric Furnace INSTALLATION INSTRUCTIONS Downflow & Upflow Models E7EM MULTI-POISE E7EU UPFLOW E7ED DOWNFLOW ATTENTION INSTALLERS: WARNING It is your responsibility to know this product better than your customer. This includes being able to install the product according to strict safety...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ....3 ELECTRICAL WIRING ..........10 Line Voltage Wiring ............10 REQUIREMENTS & CODES ........3 Connecting Supply Service Wires ........10 Minimum Installation Clearances ........3 Grounding ................11 Minimum Unobstructed Airflow ........3 Thermostat / Low Voltage Connections ......11 Clearances to Combustible Materials ......3 Humidifier .................11 Dehumidification Options ..........11...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION ALL MODELS CLOSET ALCOVE INSTALLER: Please read all instructions before servicing Front ** 6" 24" this equipment. Pay attention to all safety warnings and Back 0" 0" any other special notes highlighted in the manual. Safety Sides* 0"...
  • Page 4: Circulating Air Requirements

    CIRCULATING AIR REQUIREMENTS • Duct system must be designed so that no supply registers are located in duct system directly below the furnace. WARNING: Filtering Methods - Downflow Furnaces All return ducts must be secured to the furnace Non-Ducted Return Air with sheet metal screws.
  • Page 5: Optional Equipment

    when modifying this appliance. Refer to local authorities having jurisdiction for further information. 24 3/4” (628 mm) Before You Install this Furnace √ This equipment is securely packaged at the time of shipment and upon arrival should be carefully inspected for damage prior to installing the equipment at the job site.
  • Page 6: Standard Duct Connector Installation

    REAR WALL OF CLOSET OR ALCOVE REAR WALL OF CLOSET OR ALCOVE 1 3/4" MIN. 2 3/8" MIN. FLOOR CUT-OUT FLOOR CUT-OUT 14 1/2” X 14 1/2” 17 1/2” X 14” FOR DOWNFLOW FOR UPFLOW FURNACES WITH FURNACES WITH STD. DUCT STD.
  • Page 7: Narrow Duct Connectors

    DUCT CONNECTOR IF FLOOR CAVITY TYPE & PART NUMBER “X” IS: STANDARD DUCT SCREW DOWN DUCT CONNECTOR 7/8” / (22) 901987A 904008 SUPPLY AIR DUCT 2” / (51) 901988A 904009 4-1/4” / (108) 901989A 904010 BEND TABS TIGHTLY 6-1/4” / (159) 901990A 904011 AGAINST SUPPLY AIR DUCT...
  • Page 8: Closet Installation

    STAPLES OR SHEET METAL SCREWS DUCT CONNECTOR TABS Wall Return Air Grille Coil Air NARROW DUCT NARROW Filters DUCT DUCT FLAP 27" (686 mm) DUCT 56" (1423 mm) CONNECTOR SHEET METAL A/C or H/P SCREWS Coil NARROW DUCT 29" Furnace ( 737 mm) 24 3/4"...
  • Page 9: Through-The-Floor Return Air System (Ducted)

    7. Install return air grille in closet preferably at same level Provide min. 235 as upflow stand or below mounting platform. See Figure sq. in. (1516 cm ) open free area in front or side wall Through-the-Floor Return Air System (Ducted) or in top of 1.
  • Page 10: Electrical Wiring

    ELECTRICAL WIRING Connecting Supply Service Wires Power entrance for all models may be through the right WARNING: side or through the bottom of the unit. 1. Remove right-hand control panel (when viewing in downflow position). ELECTRICAL SHOCK, FIRE OR 2. Locate power supply knockouts in side of unit and in EXPLOSION HAZARD bottom of unit.
  • Page 11: Grounding

    Grounding DISPLAY CURRENT MODE CODE WARNING: Standby is a Rotating Segment Cooling Mode (Y input active) To minimize personal injury, the furnace cabinet Heating Mode (W input active) Circulate Fan Mode (G input active) must have an uninterrupted or unbroken electrical Dehum Cooling Mode (DEHUM input active along with Y) ground.
  • Page 12: Figures & Tables

    FIGURES & TABLES Blower Wheel Motor Assembly Blower Assembly Filter Filter Door Retainer Panel Circuit Breaker Transformer Jumper for Right Circuit Control Breaker DC Relay Door Limit Left Ground Lug Control Control Door Board Bracket Control Board Figure 16. E7 Furnace Components (Multi-Poise Shown)
  • Page 13 13 1/2” 17” VIEW VentilAire Knockout VentilAire Knockout (1 1/2” X 5”) (1 1/8” X 4 1/2”) T-Stat (Ø 5/8”) 20” 24 1/2” T-Stat RIGHT LEFT FRONT (Ø 5/8”) SIDE SIDE VIEW Electric Ø 1 1/8” 29” Ø 2” Ø 7/8” 2 1/4”...
  • Page 14 13 1/2” 17” VIEW 24 3/4” 6” 19 7/8” 4 3/8” FRONT 16 1/2” LEFT 14 7/8” RIGHT 20” VIEW SIDE SIDE 17 3/8” 2” 3 3/4” 16 1/2” BOTTOM VIEW Figure 19. E7 Furnace Upflow Stand Dimensions...
  • Page 15: Airflow Data

    Airflow Data AIRFLOW (CFM) EXTERNAL STATIC PRESSURE (IN. W.C.) MOTOR SWITCH SETTINGS MODEL (0=OFF, 1=ON) NUMBER 1,012 1,084 1,047 1,011 1,157 1,119 1,084 1,047 1,009 1,197 1,166 1,130 1,093 1,056 1,017 E7E*-0**H1 1,245 1,215 1,178 1,143 1,105 1,066 1,293 1,263 1,225 1,192 1,154...
  • Page 16: Electrical Data & Diagrams

    Electrical Data & Diagrams 5-WIRE THERMOSTAT 4-WIRE THERMOSTAT WIRE WIRE NUTS NUTS TO FURNACE CONTROL WIRING TO FURNACE CONTROL WIRING HEAT PUMP THERMOSTAT WIRE NUTS VIOLET TO FURNACE CONTROL WIRING NOTE: For optional dehumidifcation violet wire connection, refer to the Dehumidication Options section. Figure 20.
  • Page 17 MAXIMUM MODEL MINIMUM SUPPLY TOTAL OVER- NUMBER CIRCUIT CIRCUIT AMPERES CURRENT E7E*- AMPACITY RATING 010H1 Single 45.3 Single 51.6 012H1 Dual "A" 27.8 Dual "B" 24.2 Single 66.1 015H1 Dual "A" 45.3 Dual "B" 20.8 Single 71.1 017H1 Dual "A" 45.0 Dual "B"...
  • Page 18 Figure 22. E7EB-010H Models...
  • Page 19 Figure 23. E7EB-012H Models...
  • Page 20 Figure 24. E7EB-015H Models...
  • Page 21 Figure 25. E7EB-017H Models...
  • Page 22 Figure 26. E7EB-020H & E7EB-023H Models...
  • Page 23 CONTROL SIGNAL & OPERATION TOTAL KW BOARD ACTION MODE Stage 1 Heat on immediately HEAT Blower on after 3 second delay Stage 2 heat on after 10 second delay Stage 1 Heat on immediately HEAT Blower on after 3 second delay Stage 2 heat on after 10 second delay Stage 1 Heat on immediately HEAT Blower on after 3 second delay...
  • Page 24: Installation Checklist

    Has the literature package been left near the furnace? Complies with H.U.D. Manufactured Home Construction & Safety Standards. Specifications & illustrations subject to change without notice or incurring obligations (06/19). 10257240 O’Fallon, MO, © Nortek Global HVAC LLC 2019. All Rights Reserved. (NEW)
  • Page 25: Installation Instructions

    INSTALLATION INSTRUCTIONS C84DA Series Split System Uncased Indoor Coils - Downturn IMPORTANT For installation only in or with a mobile home furnace, modular blower, or designated air mover that complies with HUD Manufactured Home Construction Safety Standard 24 CFR part 3280. IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer.
  • Page 26: Important Safety Information

    IMPORTANT SAFETY INFORMATION WARNING: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special This unit must be installed in accordance notes highlighted in the manual. Safety markings are with the instructions outlined in this manual used frequently throughout this manual to designate a during the installation, service, and operation degree or level of seriousness and should not be ignored.
  • Page 27: General Information

    GENERAL INFORMATION COIL INSTALLATION C84DA series coils are designed for upflow or downflow WARNING: applications and are equipped with down turned refrigerant connections and are ready for brazing. ELECTRICAL SHOCK, FIRE OR EXPLOSION • Check the coils orifice size and confirm that it’s suitable HAZARD for application with the intended outdoor unit.
  • Page 28: Condensate Drain

    Refrigerant Line Connections Condensate Drain System Depressurization CAUTION: 1. Remove the cap (Figure 1) from the end of the liquid line. 2. Verify pressurization by depressing the Schrader valve The coil must be level to ensure proper on the end of the liquid line. Listen for any escaping gas. condensate drainage.
  • Page 29: Air Filter

    Air Filter Air filters are not supplied as an integral part of this coil; however, an air filter kit is available. Refer to the Replacement Parts List for available part numbers. The filter must be installed upstream of the coil and inspected frequently.
  • Page 30 COIL SPECIFICATIONS & DIMENSIONS C84DA- Nominal Capacity (BTU/hour) 24,000 30,000 36,000 42,000 42,000 48,000 48,000 60,000 Nominal Airflow (CFM) 1,000 1,200 1,400 1,400 1,600 1,600 2,000 W - Width (in.) 18 1/8 18 1/8 18 1/8 18 1/8 18 1/8 18 1/8 18 1/8 18 1/8...
  • Page 32 INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH THE EQUIPMENT OWNER. Specifications & illustrations subject to change without notice or incurring obligations (10/22). 10441300 O’Fallon, MO, © Nortek Global HVAC LLC 2022. All Rights Reserved. (Replaces 1040996A)
  • Page 33 SPLIT SYSTEM AIR CONDITIONER 14.3 SEER2 INSTALLATION INSTRUCTIONS RSA3ME4M1 - RN24K, RN30K, SN36K, SN42K, SN48K & SN60K (2, 2.5, 3, 3.5, 4 & 5 TON) SERIES - SINGLE PHASE MODELS IMPORTANT IMPORTANT SAFETY INFORMATION ....2 AIR CONDITIONER INSTALLATION ..... 2 General Information ..........
  • Page 34: Important Safety Information

    IMPORTANT SAFETY INFORMATION CAUTION: INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any This unit uses refrigerant R-410A. DO NOT use other special notes highlighted in the manual. Safety markings any other refrigerant in this unit. Use of another are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored.
  • Page 35: Packaging Removal

    local building codes. If there is any question concerning • Overhead obstructions (Figure 1), poorly ventilated areas, the power supply, contact the local power company. and areas subject to accumulation of debris should be √ The indoor section (air handler, furnace, etc) should be avoided.
  • Page 36: Electrical Wiring

    ELECTRICAL WIRING CAUTION: WARNING: When performing brazing operations always protect the system components and seals from ELECTRICAL SHOCK OR FIRE HAZARD the possibility of heat damage. Remove all To avoid risk of electrical shock, personal injury, caps, plugs and Schrader valve cores on piping or death, disconnect all electrical power to the unit system components just prior to assembly and before performing any maintenance or service.
  • Page 37: Grounding

    √ Verify that the low voltage and thermostat wiring are • Use only copper wire for the line voltage power supply to this unit in strict accordance of the NEC (ANSI/NFPA 70), securely connected to the proper terminals for all applicable local codes, and the instructions provided with equipment.
  • Page 38: Air Conditioner Maintenance

    AIR CONDITIONER MAINTENANCE WARNING: To prevent electrical shock, personal injury, or death, disconnect all electrical power to the unit before performing any maintenance or service. The unit may have more than one electrical supply. Proper maintenance is important to achieve optimum performance from the air conditioner.
  • Page 39: Refrigerant Charging

    • If your measured superheat at the suction valve Nortek indoor units. For reference, these units are listed is GREATER THAN the recommended superheat in the AHRI Directory with all approved combinations value in the table then ADD refrigerant.
  • Page 40: Wiring Diagram

    WIRING DIAGRAM Split System Air Conditioner (Outdoor Section) Single Phase NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3.
  • Page 41 WIRING DIAGRAM Split System Air Conditioner (Outdoor Section) Single Phase NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3.
  • Page 42 Figure 6. Wiring Diagram for RSA3ME4M1SN (5 Ton Units)
  • Page 44: Installation Checklist

    COMPONENTS: • Blower Assembly • Fan Grille • Cabinet Panels • Filter/Driers • Expansion Valves Specifications & illustrations subject to change without notice or incurring obligations (09/22). 10439230 O’Fallon, MO, © Nortek Global HVAC LLC 2022. All Rights Reserved. (NEW)

This manual is also suitable for:

E7emE7euE7ed

Table of Contents