8.3
Performance data
8.3.1
Taurus XQ 350 Synergic C
Welding current I
Welding voltage according to standard U
Duty cycle DC at 40°C/104°F
Mains voltage
mains fuse
(380-400 V)
[3]
mains fuse
(440-460 V)
[3]
mains fuse
(480-500 V)
[3]
Open circuit voltage U
Open circuit voltage U
Open circuit voltage U
max. Connected load S
max. Connected load S
(F06W)
Recommended generator power
Power consumption P
max. Mains impedance (@PCC)
Cos φ / efficiency
Protection class / Overvoltage category
Contamination level / Insulation class
protection classification / Residual current
circuit breaker
Noise level
[5]
Ambient temperature
Machine cooling / Torch cooling
Mains connection cable
min. Workpiece lead / EMC class
Wire feed speed
Factory-installed roll equipment / Drive
Wire spool diameter
Welding torch connection
Test mark
Standards used
Load cycle: 10 min. (60 % DC ≙ 6 min. welding, 4 min. pause) AC power sources: 50 Hz - waveform =
[1]
square.
Multi-voltage machine – the power source can be adapted to the mains voltage.
[2]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger
[3]
characteristic must be used.
Power in idle state without external or internal peripherals.
[4]
Noise level during idle mode and operation under standard load according to IEC 60974‑1 at the
[5]
maximum operating point.
Ambient temperature dependent on coolant! Observe coolant temperature range!
[6]
099-005653-EW501
7.11.2024
2
[1]
/ Frequency / Tolerance
[2]
(380-400 V)
0
(440-460 V)
0
(480-500 V)
0
, gas cooled (F06G)
1
, water cooled
1
[4]
i
[6]
MIG/MAG
14,3 V to 31,5 V
2
3 x 380-400 V / 50/60 Hz / -25 % to+20 %
3 x 440-460 V / 50/60 Hz / -25 % to+15 %
3 x 480-500 V / 50/60 Hz / -25 % to+10 %
3 x 20 A
3 x 20 A
3 x 16 A
13,9 kVA
14,3 kVA
19,8 kVA
IP 23 / Type B (recommended)
-25 °C to +40 °C / -13 °F to 104 °F
Fan (AF) / gas or water
1,0-1,2 mm for steel wire / 4 rollers (37 mm)
Standardised wire spools up to 300 mm
See declaration of conformity (appliance documents)
Technical data
Performance data
MMA
5 A to 350 A
20,2 V to 34,0 V
10,2 V to 24,0 V
350 A (80 %)
320 A (100%)
3 x 20 A
3 x 20 A
3 x 16 A
82 V
94 V
102 V
15,1 kVA
15,1 kVA
20,4 kVA
32 W
107 mOhm
0,99 / 90 %
Ⅰ / Ⅲ
3 / H
<70 dB(A)
H07RN-F4G6
70 mm
/ A
2
0,5 m/min to 25m/min
Euro torch connector
/
/
/
TIG
3 x 16 A
3 x 16 A
3 x 16 A
10,6 kVA
11,0 kVA
15,3 kVA
69
Need help?
Do you have a question about the Taurus XQ 400 Synergic C and is the answer not in the manual?