Important Notes to the Installer
1. Read allinstructions contained i nthese installation
instructions before installing t hecooktop.
2. Remove a llpacking material before connecting the
electrical supply t o thecooktop.
3. Observe allgoverning c odes a ndordinances,
4. Besure to leave these instructions withtheconsumer.
5. Only' certain cooktop models may beinstalled o ver
certain built-in electric o ven models, Approved
cooktops a ndbuilt-in ovens a relisted bytheMFG ID
number a ndproduct c ode.(Refer to document
#318059843)
Important Note to the Consumer
Keep these instructions withyourUse andCare Guide for
futurereference.
IMPORTANT SAFETY
• Be sure your
cooktop
is installed
and grounded
properly
by a qualified
installer
or service
technician,
• This cooktop
must
be electrically
grounded
in
accordance
with
local
codes
or, in their
absence,
with
the National
Electrical
Code ANS[/NFPA
No.
70--latest
edition
in the United
States,
_The
electrical
power
to the cooktop
must be shut off while
line connections
are being
made, Failure to do so could result in serious injury
or death,
Provide
Electrical
Connection
Install the junction box under tile cabinet and run 120/
240 or 120/208 Volt, AC wire from tile main circuit
panel. NOTE: DO NOT connect tile wire to the circuit
panel at this time.
Electrical
Requirements
Observe all governing
codes and local ordinances.
1.
A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral.
2.
A circuit breaker or fuse rated at 40 Amp is
recommended for this appliance.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with tile National Electrical Code ANS!/NEPA No. 70-
latest edition and local codes and ordinances.
An extension
cord must not be used
with this appliance.
Such use may result in a fire,
electrical
shock, or other personal
injury.
3.
The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
Tile junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
tile cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
4.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking
Instructions
1.
Unpack and visually inspect the cooktop.
2.
Be sure the bottle of cleaner conditioner packed in
the literature bag is left where the user can find it
easily. It is important that the ceramic-glass cooktop
be pretreated before use. See Cooktop
Cleaning
and Maintenance
section in the Use and Care
Guide.
Electrical
Connection
Connect tile flexible armored cable that extends from
tile surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make tile electrical connection as
follows.
Electrical
ground
is required
on this appliance.
This appliance
is equipped
with a
copper conductor
f[exibIe
cable. If connection
is
made to aluminum
house wiring,
use only speda[
connectors
which are approved
for joining
copper
and aluminum
wires in accordance
with
the
National
Electrical
Code and [oca[ codes and
ordinances.
Improper
connection
of aluminum
house wiring
to copper leads can result in a short
circuit or fire. Follow the connector
manufacturer
recommended
procedure
closely,
This appliance is manufactured with a supply wire and a
frame connected green or bare copper grounding wire.