Important Notes to the Installer
1. Read a llinstructions contained i nthese installation
instructions before installing t hecooktop.
2. Remove a llpacking material before connecting the
electrical supply t othecooktop.
3. Observe allgoverning c odes a ndordinances.
4. Besure to leave t hese instructions withtheconsumer.
Important Note to the Consumer
Keep these instructions withyourowner's g uide forfuture
reference.
IMPORTANT
SAFETY
INSTRU
S
Be sure your cooktop is installed and grounded
properly
by a qualified
installer
or service
technician.
These cooktops
must be etectrkaHy
grounded
in
accordance
with
local codes or, in their absence,
with the National
EJectricat Code ANSJ/NFPA No.
70--Jatest
edition
in the United States, or with
CSA Standard
C22.1, Canadian
Electrical
Code, Part
1, in Canada.
The electrical
power
to the cooktop
must be shut off while
line connections
are being
made. Faiture to do so coutd resutt in serious injury
or death.
Provide
Electrical
Connection
Install the junction box under the cabinet and run 120/
240 or 120/208 Volt, AC wire from the main circuit
panel. DO NOT connect the wire to the circuit panel at
this time.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with tile National Electrical Code ANS!/NFPA No. 70-
latest edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local codes and ordinances.
An extension
cord
must
not
be used
with
this
appliance.
Such use may result
in a fire,
electrical
shock,
or other
personal
injury.
2.
Tile appliance should be connected to tile fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed (:able. The flexible
armored cable extending from this appliance should
be connected directly to the grounded junction box.
Tile junction box should be located as shown in
Figure 2 with as much slack as possible remaining in
tile cable between the box and the appliance, so it
can be moved if servicing is ever necessary.
3.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Electrical
Connection
Connect tile flexible armored (:able that extends from
tile surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
described on next page.
Electrical
ground
is required
on this
appliance,
This appliance is equipped with a copper conductor
flexible cable. If connection is made to aluminum house
wiring, use only special connectors which are approved
Electrical
Requirements
Observe all governing
codes and tocaJ ordinances,
1.
A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO
NOT fuse neutral. The fuse size must not exceed the
circuit rating of tile appliance specified on tile
nameplate.
2.
This unit (:an consume up to 7300W at 240Vac, a
circuit breaker of 40 Amp with wire gauge #SAWG
shall be used.