Aquagem Fairland INVERX DE14 Installation And Operation Manual

Inverter pool pump
Hide thumbs Also See for Fairland INVERX DE14:

Advertisement

INVERTER POOL PUMP
I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L
Follow this QR code for manual in other language
Suivez ce QR code pour consulter le manuel en francais
Volg deze QR-code om de handleiding in het Nederlands te raadplegen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fairland INVERX DE14 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aquagem Fairland INVERX DE14

  • Page 1 INVERTER POOL PUMP I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L Follow this QR code for manual in other language Suivez ce QR code pour consulter le manuel en francais Volg deze QR-code om de handleiding in het Nederlands te raadplegen...
  • Page 2: Table Of Contents

    CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................1 2. TECHNICAL SPECIFICATIONS ......................3 3. OVERALL DIMENSION (mm) ........................ 3 4. INSTALLATION ............................4 5. SETTING AND OPERATION ........................6 6. EXTERNAL CONTROL .......................... 12 7. PROTECTION AND FAILURE ....................... 13 8. MAINTENANCE ............................17 9.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This guide provides installation and operation instructions for this pump. If you have any other questions about this equipment, please consult your supplier. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1.1 IEC This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental...
  • Page 4 be used with hot tubs and spas with a water temperature under 50℃. Due to the fixed installation method, this pump is not suggested to be used on above-ground pools that can be readily disassembled for storage. 1.10 The pump is not submersible. 1.11 Never open the inside of the drive motor enclosure.
  • Page 5: Technical Specifications

    2. TECHNICAL SPECIFICATIONS Advised Pool Circulation (m³/h) Voltage Qmax Hmax Model Volume (V/Hz) (m³/h) At 10m At 8m (m³) DE14 20-40 0.60 18.0 14.0 14.5 DE18 30-50 0.75 21.0 16.0 14.0 18.0 220-240 / 50/60 DE22 40-70 1.00 25.5 18.0 18.0 22.0 DE27...
  • Page 6: Installation

    4. INSTALLATION 4.1. Pump Location 1) Install the pump as close to the pool as possible, to reduce friction loss and improve efficiency, use short, direct suction and return piping. 2) To avoid direct sunshine, heat or rain, it is recommended to place the pump indoors or in the shade. 3) DO NOT install the pump in a damp or non-ventilated location.
  • Page 7 4.3. Fittings 1) Elbows should be no closer than 350mm to the inlet. Do not install 90° elbows directly into the pump inlet/outlet. This will help the pump prime faster and last longer. 2) Joints must be tight. Elbow Return to pool 63mm (recommended) ≥350mm Suction 63mm...
  • Page 8: Setting And Operation

    4.4. Check before initial startup 1) Check whether the pump shaft rotates freely; 2) Check whether the power supply voltage and frequency conform to the nameplate; 3) Facing the fan blade, the direction of motor rotation should be clockwise; 4) It is forbidden to run the pump without water. 4.5.
  • Page 9: Step 3:Self-Checking

    5.2. Startup process overview ① Step 1:Startup Press and hold for more than 3 seconds to unlock the screen.  Press to startup the pump.  ② Step 2:Self-priming The pump will start counting down from 1500s; When the system detects the pump is full of water, it will ...
  • Page 10 5.3. Startup When the power is switched on, the screen will fully light up for 3 seconds, the device code will be displayed, and then it will enter the normal working state. When the screen is locked, only the button will light up;...
  • Page 11 5.5. Backwash Users can start the backwash or fast re-circulation in any running state by pressing Default Setting range Press to adjust from 0 to 1500s with 30 seconds Time 180s for each step Running capacity 100% 80-100%, enter the parameter setting (see 5.8) Exit backwash: When backwash mode is on, users can hold for 3 seconds to exit, the pump will return to the previous...
  • Page 12 When enter the timer-1 setting, the timer indicator 1 will light up. “StA”will be shown on the screen. Press to proceed and then press to set the start time of timer-1 (with 30 minutes for each step), press to confirm. When the start time of timer 1 is confirmed, “End”will be shown on the screen.
  • Page 13 5.8. Parameter Setting Restore factory Under OFF mode, hold both for 3 seconds setting Check the Under OFF mode, hold both for 3 seconds software version Under OFF mode, hold both for 3 seconds to enter the parameter setting. The parameter address (on the left) and default setting Enter the value (on the right) will flash alternately on the screen.
  • Page 14: External Control

    6. EXTERNAL CONTROL External control can be enabled via following contacts. The priority is as below: Digital Input > Panel control. Connector for Digital Input AC Power Input Figure 4 - Connector port location 5 PINs connector for Digital Input Figure 5 - Digital Input connector...
  • Page 15: Digital Input

    Brown L Blue N Yellow and Green PE Figure 6 - Power cord connection External Control Color Description Di4(Digital Input 4) Black Di3(Digital Input 3) Digital Input White Di2(Digital Input 2) Grey Di1(Digital Input 1) Yellow Digital Ground(COM) Digital Input: Running capacity is determined by the state of digital input, 1) When Di1(Grey) connects with COM(Yellow), the pump will be mandatory to stop;...
  • Page 16: Undervoltage Protection

    If AL01 is displayed for the first time, the running capacity will be automatically reduced as below: If current operating capacity is higher than 85%, the running capacity will be automatically reduced by 15%; If current operating capacity is between 70% and 85%, the running capacity will be automatically reduced by 10%;...
  • Page 17 7.4. Error code When the device detects a failure, it will stop automatically and display the error code. After stopping for 15 seconds, check if the failure is cleared. If cleared, the pump will resume working. Item Error Code Details Abnormal input voltage: the power supply voltage is out of the Description range of 165V to 275V.
  • Page 18 to 420V. The pump will stop automatically for 15 sec and then resume Process working,if this occurs for thrice continuously, the pump will shut down and need to be checked and restarted manually. PFC protection:PFC protection occurs on the Master driver board. Description The pump will stop automatically for 15 sec and then resume E107...
  • Page 19: Maintenance

    Check the pump or pipeline that there is no leakage, and then fill up Process the pump with water and restart it. 8. MAINTENANCE Empty the strainer basket frequently. The basket should be inspected through the transparent lid and emptied when there is an evident stack of rubbish inside.
  • Page 20 MFD BY Aquagem Manufacturing Limited NO.15, 101, 16, 401, 501, NO.193, Jinlong Road, Dalong Street, Panyu District, Guangzhou www.aquagem.com IMPORTED BY Pollet Pool Group Textielstraat 13, 8790 Waregem, Belgium www.polletpoolgroup.com AG024-DE-02...