  • Page 2 CONTENTS IMPORTANT SAFETY INSTRUCTIONS ........................1 2. TECHNICAL SPECIFICATIONS ..............................3 3. OVERALL DIMENSION (mm) ..............................3 4. INSTALLATION ................................... 4 5. SETTING AND OPERATION ..............................6 6. WIFI OPERATION ..................................12 7. EXTERNAL CONTROL (OPTIONAL) .............................20 8. PROTECTION AND FAILURE ..............................21 9.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS This guide provides installation and operation instructions for this pump. If you have any other questions about this equipment, please consult your supplier. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1.1 IEC This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental...
  • Page 4 be used with hot tubs and spas with a water temperature under 50℃. Due to the fixed installation method, this pump is not suggested to be used on above-ground pools that can be readily disassembled for storage. 1.10 The pump is not submersible. 1.11 Never open the inside of the drive motor enclosure.
  • Page 5 2. TECHNICAL SPECIFICATIONS Advised Pool Circulation (m³/h) Voltage Qmax Hmax Model Volume (V/Hz) (m³/h) At 10m At 8m (m³) DE14 20-40 0.60 18.0 14.0 14.0 DE18 30-50 0.75 21.0 16.0 14.0 18.0 220-240/ DE22 40-70 1.00 50/60 25.5 18.0 18.0 22.0...
  • Page 6 4. INSTALLATION 4.1. Pump Location 1) Install the pump as close to the pool as possible, to reduce friction loss and improve efficiency, use short, direct suction and return piping. 2) To avoid direct sunshine, heat or rain, it is recommended to place the pump indoors or in the shade. 3) DO NOT install the pump in a damp or non-ventilated location.
  • Page 7 4.3. Valves and Fittings Elbows should be no closer than 350mm to the inlet. Do not install 90° elbows directly into the pump inlet/outlet. Joints must be tight. Elbow Return to pool 63mm 350mm Suction 63mm Figure 2 * The pump inlet/outlet union size: optional with 48.5/50/60.3/63mm 2) Flooded suction systems should have gate valves installed on suction and return line for maintenance;...
  • Page 8 4.5 Application conditions Ambient temperature Indoor installation, pump is intended for continuous operation at this temperature range: -10 - 42℃ Water temperature 5℃-50℃ Salt pools Salt concentration up to 0.5%, i.e 5g/l Humidity ≤90% RH, (20℃±2℃) Altitude Not exceed 1000m above sea level Installation The pump can be installed max.
  • Page 9 5.2 Startup process overview: ① Step1:Startup Press and hold for more than 3 seconds to unlock the screen.  Press to startup the pump.  ② Step2:Self-priming The pump will start counting down from 1500s; When the system detects the pump is full of water, it will ...
  • Page 10 5.3 Startup: When the power is switched on, the screen will fully light up for 3 seconds, the device code will be displayed, and then it will enter the normal working state. When the screen is locked, only the button will light up;...
  • Page 11 5.5 Backwash Users can start the backwash or fast re-circulation in any running state by pressing Default Setting range Time 180s Press to adjust from 0 to 1500s with 30 seconds for each step Running capacity 100% 80-100%, enter the parameter setting (see 5.8) Exit backwash: When backwash mode is on, users can hold for 3 seconds to exit, the pump will return to the previous...
  • Page 12 Enter timer setting by pressing Press to set the local time. Press to confirm and move to timer-1 setting. When enter the timer-1 setting, the timer indicator 1 will light up. “StA”will be shown on the screen. Press to proceed and then press to set the start time of timer-1 (with 30 minutes for each step), press to confirm.
  • Page 13 6) Users can hold for 3 seconds to read the real-time power and it will return to the timer display after 10s without operation. 7) Users can exit the timer mode by holding for 3 seconds. 5.8 Parameter Setting Restore factory Under OFF mode, hold both for 3 seconds setting...
  • Page 14 6. WIFI OPERATION Download InverFlow APP Account Registration Email Registration...
  • Page 15 Third-party application registration Create Home Please set home name and choose the location of the device. (It is recommended to set the location so the weather can be shown in the App for your convenience)
  • Page 16 App pairing Please make sure your pump is turned on before you start. Option 1 (Recommended): With Wifi and Bluetooth (Network requirement: 2.4GHz; 2.4Ghz and 5GHz into one SSID; but no separate 5GHz network) 1) Please confirm that your phone is connected to Wifi and your Bluetooth is on. 2) Press for 3 seconds until hearing “Beep”...
  • Page 17 Option 2: With Wifi (Network requirement: 2.4GHz only) Please confirm that your phone is connected to Wifi Press for 3 seconds until hearing “Beep” to unlock the screen. Press for 5 seconds until hearing “Beep” and then release. will flash. Click “Add Device”, and then follow the instructions to pair device.
  • Page 18 Operation Using Manual Inverter mode: Real-time power consumption Turn the control dial to set the running capacity Manual Inverter mode Backwash mode Data Timer On/off Using Backwash mode: Real-time power Backwash countdown consumption Turn the control dial to set the backwash time Manual Inverter mode Backwash mode...
  • Page 19 Notice for the timer setting via the APP: Time variance is ±30s; In order to avoid overlapping timing points conflicting and invalidating due to network delay, it is recommended that the end time and the start time of the next timing period cannot overlap, and a sufficient time interval should be reserved, for example, at least 2 minutes;...
  • Page 20 Sharing Devices with your family members After pairing, if your family members also want to control the device, please let your family members register “InverFlow” first, and then the administrator can operate as below:...
  • Page 21 Feedback If you have any problem while using, welcome to send feedback. Notice: The weather forecast is just for reference; The power consumption data is for reference only, as it may be affected by network problems and imprecision of the calculation. The App is subject to updates without notice.
  • Page 22 7. EXTERNAL CONTROL (OPTIONAL) External control can be enabled via following contacts. Connector for configurable user inputs, including Digital Input 、RS485 and Relay output AC Power Input Figure 3 7 PINs connector for Digital Input and RS485(Optional) Relay Output(Optional) Brown L Blue N Figure 4 Yellow and Green PE...
  • Page 23 Name Color Description PIN 1 Digital Input 4 PIN 2 Black Digital Input 3 PIN 3 White Digital Input 2 PIN 4 Grey Digital Input 1 PIN 5 Yellow Digital Ground PIN 6 Green RS485 A PIN 7 Brown RS485 B Digital input(optional)...
  • Page 24 8.2 Undervoltage protection When the device detects that the input voltage is less than 198V, the device will limit the current running speed. The display area alternately displays AL02 and running speed. When input voltage is less than or equal to 180V, the running capacity will be limited to 70%; When the input voltage range is within 180V - 190V, the running capacity will be limited to 75%;...
  • Page 25 8.4 Error code When the device detects a failure, it will stop automatically and display the error code. After stopping for 15 seconds, check if the failure is cleared. If cleared, the pump will resume working. Item Error Code Details E001 Description Abnormal input voltage: the power supply voltage is out of the...
  • Page 26 E108 Description Motor power overload: Motor power exceeds the rated power by 1.2 times Process Same process as E002 E201 Description Circuit board error:When the pump power off,the bias voltage of the sampling circuit is out of the range of 2.4V~2.6V. Process The pump needs to be powered off and restarted manually.
  • Page 27 9. MAINTENANCE Empty the strainer basket frequently. The basket should be inspected through the transparent lid and emptied when there is an evident stack of rubbish inside. The following instructions should be followed: 1). Disconnected the power supply. 2). Unscrew the strainer basket lid anti-clockwise and remove. 3).