Rauch E-CLICK Original Instructions Manual

For the axis and mds fertilizer spreader
Hide thumbs Also See for E-CLICK:

Advertisement

Quick Links

Complementary instructions
Please read carefully
before using the
machine!
Keep for future use
This operator's and assembly manual is
an integral part of the machine. Suppliers
of new and second-hand machines are
required to document in writing that the
operator's and assembly manual was
delivered with the machine and handed
over to the customer.
d
5901360-
-en-0225
Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-CLICK and is the answer not in the manual?

Questions and answers

Summary of Contents for Rauch E-CLICK

  • Page 1 Complementary instructions Please read carefully before using the machine! Keep for future use This operator's and assembly manual is an integral part of the machine. Suppliers of new and second-hand machines are required to document in writing that the operator's and assembly manual was delivered with the machine and handed over to the customer.
  • Page 2 Dear customer, By purchasing the E-CLICK control unit for the AXIS and MDS fertilizer spreader, you have shown confidence in our product. Thank you very much! We want to justify this confidence. You have purchased a powerful and reliable machine control unit.
  • Page 3: Table Of Contents

    Connect control unit 4 Operation Switching on the machine control unit Rocker switch switching positions Setting the application rate Reference run 5 Spreading operation 6 Error message Short circuit Not connected Close the metering slide 7 Guarantee and warranty E-CLICK AXIS-M/MDS 5901360...
  • Page 4 Table of contents 5901360 E-CLICK AXIS-M/MDS...
  • Page 5: User Instructions

    Always observe the measures described to prevent this danger. WARNING! Type and source of danger This warning warns of a potentially dangerous situation for personal health. Ignoring these warnings leads to severe injury. Always observe the measures described to prevent this danger. E-CLICK AXIS-M/MDS 5901360...
  • Page 6: Notes On Text Descriptions

    Lists without a specific sequence are shown as lists with bullet points: • Property A • Property B 1.3.3 References References to other sections in the document are shown with paragraph number, header text and/or page number: • Example: Please also note 2 Layout and function 5901360 E-CLICK AXIS-M/MDS...
  • Page 7 1. User instructions References to other documents are shown as information or instructions without the exact chapter or page number: • Example: Follow the instructions in the operator’s manual of the universal drive shaft manufacturer. E-CLICK AXIS-M/MDS 5901360...
  • Page 8: Layout And Function

    MDS 14.2 C AXIS-M 30.1/30.2 C MDS 12.1 C MDS 18.2 C AXIS-M 40.1/40.2 C MDS 17.1 C MDS 20.2 C AXIS-M 50.1 C MDS 19.1 C Layout of the control unit Fig. 1: Control unit E-CLICK 5901360 E-CLICK AXIS-M/MDS...
  • Page 9: Control Elements

    The opening and closing of the metering slide during spreading is controlled with 2 rocker switches on the control unit. Fig. 2: Arrangement of the rocker switches Left-hand rocker switch: Controls the left- Right-hand rocker switch: Controls the right- hand metering slide hand metering slide E-CLICK AXIS-M/MDS 5901360...
  • Page 10: Status Indication

    2. Layout and function Status indication Multicolored LEDs indicate the status of the metering slides on the display side of the E-CLICK unit. The color change indicates whether the metering slides are open, closed or in motion. Fig. 3: Multicolored LEDs...
  • Page 11: Technical Specifications

    A nameplate is attached to the rear of the E‑CLICK control unit, on which you can find important information about your unit. Always keep this information to hand for contact with your RAUCH contact person! Technical data E‑CLICK Rated voltage...
  • Page 12: Attachment And Installation

    Power supply The tractor supplies the machine control with power via the 3-pin connector (DIN 9680/ISO 12369). Fig. 4: PIN assignment of power socket PIN 1: is not required PIN 3: (31): Ground PIN 2: (15/30): +12 V 5901360 E-CLICK AXIS-M/MDS...
  • Page 13: Attaching The Control Unit

    Fig. 5: Mounting bracket installation Select a suitable position in the tractor cabin (within the driver's field of vision) to which you want to secure the E‑CLICK control unit. Attach the control unit to the selected position with the bracket. E-CLICK AXIS-M/MDS 5901360...
  • Page 14: Connect Control Unit

    3-pin plug connector conforming to DIN Machine cable 9680/ISO 12369 4-pin machine plug Metering slide actuator, right [10] 4-pin machine plug Dosing slider actuator, left [11] Control unit E‑CLICK Machine cable plug connector for actuator, left 5901360 E-CLICK AXIS-M/MDS...
  • Page 15: Operation

    In order to avoid overloading the actuator motors, the actuators are automatically switched off when acting against a blockage. Requirements for spreading operation with the E‑CLICK control unit: The slide openings on the mineral fertilizer spreader are set correctly! E-CLICK AXIS-M/MDS 5901360...
  • Page 16: Setting The Application Rate

    In the event of a fault, the metering slide can open unexpectedly. There is a risk of injury to persons due to moving machine parts. Before working on the metering slides, the E‑CLICK control unit must always be disconnected from the electrical system! 5901360 E-CLICK AXIS-M/MDS...
  • Page 17: Reference Run

    The LEDs go out if you switch to the neutral position during the process and thus interrupt the operation of the actuators. The E‑CLICK control unit cannot detect the state of the actuators. • Carry out another reference run. E-CLICK AXIS-M/MDS 5901360...
  • Page 18: Spreading Operation

    Fertilizer application begins. Close the desired metering slides by actuating the rocker switches in the CLOSE switching state. Closes the metering slide. No more fertilizer flows through. Stop spreading discs. Stop the tractor. Spreading work is complete. 5901360 E-CLICK AXIS-M/MDS...
  • Page 19: Error Message

    To remedy the fault, reconnect the actuator to E‑CLICK. Possible causes: • a defective cable (cable break) • a defective or unplugged actuator • an unplugged machine cable E-CLICK AXIS-M/MDS 5901360...
  • Page 20: Close The Metering Slide

    LEDs change from orange to red. Switching the rocker switch to CLOSE again results in the LED for the affected metering slide side beginning to flash red. This behavior is normal for repeated closing. • There is no fault in this case. 5901360 E-CLICK AXIS-M/MDS...
  • Page 21: Guarantee And Warranty

    • Claims for damage other than to the RAUCH devices will not be accepted. This also means that no liability will be accepted for damage resulting from spreading errors. Unauthorized modifications of the RAUCH devices may result in consequential damage, for which the manufacturer will not accept any liability.

Table of Contents