Installation, Operation, Maintenance and Service Instructions Fryer Model: 130F Star Manufacturing International 10 Sunnen Drive St. Louis, MO.63143-3800 Part Number: 2M-W478 Ph: 314-781-2777 Fax: 314-781-2714 WWW.STAR-MFG.COM Rev. B June 19, 2007...
Page 2
EACH UNIT IS HEAVY. FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION. CAUTION ANY STAND, COUNTER OR OTHER DEVICE ON WHICH FRYER WILL BE LOCATED MUST BE...
Page 3
READ THE WARNING AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. NOTICE: Service on this or any other, STAR appliance must be performed by qualified personnel only. Consult your authorized service agent directory or call the factory at...
Electric Fryer Counter Model The fryer dimensions are 19” (48.25cm) High, 32” (81.25cm) Deep, 15” (38cm) wide. The sides, bottom, and rear wall are constructed stainless steel. Floor Models The interior dimensions are 36” (91.5cm) High, 38” (96.5cm) Deep, 15” (38cm) wide. The Sides, Bottom, and Rear wall are constructed stainless steel.
15 days of delivery. All packing material should be kept for inspection. Do not return damaged merchandise to Star Manufacturing Company.File your claim with the carrier. Prior to un-crating, move the fryer as near its intended location as practical. The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways.
General General Operation Fill the fryer with cooking oil. There are two fill marks on the sides of the kettle. The oil level should be maintained between the upper and lower marks. The power switch on the control box at the front of the fryer energizes the control circuits.
Sequence of Operation Electric Fryer ower switch to “ON” position 208/240 VAC to “POWER” pilot lamp. 208/240 VAC to Thermostat through Over-Temperature thermostat. Thermostat Set 208/240 VAC to “HEAT” pilot lamp. 208/240 VAC to Contactors. Contactors Energize 208/240 VAC to Elements. Elements Energize Fryer heats up.
Maintenance Maintenance of the C-28 series fryers is simple and straightforward. A bulb thermostat located near the right heating element as the fryer is viewed from the front provides temperature control. This thermostat controls the No. 1 contactor. The over temperature thermostat located next to the left heating element provides protection in case of malfunction of the temperature control.
Troubleshooting Will Not Heat PROBABLE CAUSE CORRECTIVE ACTION Confirm that correct voltage is coming to unit. Incorrect voltage Confirm that unit is phased correctly. Confirm that fuses have 208/240 VAC to it. Defective Fuses Check fuses for proper operation. Confirm that switch has 208/240 VAC to it. Defective Power Switch Check switch for proper operation.