Publishing information B&R Industrial Automation GmbH B&R Strasse 1 5142 Eggelsberg Austria Telephone: +43 7748 6586-0 Fax: +43 7748 6586-26 office@br-automation.com Disclaimer All information in this manual is current as of its creation. The contents of this manual are subject to change without notice.
Fig. 67 "5AP920.1706-01 - Temperature/Humidity diagram > Rev. D0" on page • Updated photos of 5CASDL.0x00-13 SDL cables with an extender. • Changed Fig. 127 "5CASDL.0xxx-03 - Pinout" on page 168. Deleted structure of 5CASDL.0xxx-03 SDL cables. Table 1: Manual history Automation Panel 900 user's manual V2.22...
Page 9
Fig. 108 "5AP951.1505-01 / 5AP981.1505-01 - Hardware numbers" on page 136. • Updated section 2.2.5 "Block diagrams" on page • Updated USB interface covers 5AC900.1200-01, 5AC900.1200-02 and 5AC900.1200-03. • Discontinued USB interface cover 5AC900.1200-00. Table 1: Manual history Automation Panel 900 user's manual V2.22...
Page 10
"Block diagrams" on page 2.22 January 2022 • Updated technical data of the panels in section "Individual components" on page 27 and section "Stan- dards and certifications" on page 148. Table 1: Manual history Automation Panel 900 user's manual V2.22...
• A minimum distance of 10 cm from monitors or television sets must be maintained. • Measuring instruments and devices must be grounded. • Test probes of floating potential measuring instruments must be discharged briefly on suitable grounded surfaces before measurement. Automation Panel 900 user's manual V2.22...
This can otherwise result in dust deposits that affect the functionality of the device, especially in systems with active cooling (fans), which may no longer ensure sufficient cooling. Automation Panel 900 user's manual V2.22...
The term "control systems" refers to all types of B&R products such as controllers (e.g. X20), HMI systems (e.g. Power Panel T30), process control systems (e.g. APROL) and supporting systems such as engineering workstations with Automation Studio. Automation Panel 900 user's manual V2.22...
Up to 6 mm ±0.1 mm Over 6 to 30 mm ±0.2 mm Over 30 to 120 mm ±0.3 mm Over 120 to 400 mm ±0.5 mm Over 400 to 1000 mm ±0.8 mm Automation Panel 900 user's manual V2.22...
RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m 9A0014.05 RS232 extension cable for remote operation of a display unit with touch screen, 5 m 9A0014.10 RS232 extension cable for remote operation of a display unit with touch screen, 10 m Automation Panel 900 user's manual V2.22...
Page 16
5MMUSB.4096-01 USB 2.0 flash drive, 4096 MB, B&R USB cables 5CAUSB.0018-00 USB 2.0 connection cable type A - type B, 1.8 m 5CAUSB.0050-00 USB 2.0 connection cable type A - type B, 5 m Automation Panel 900 user's manual V2.22...
PC systems. As a result, the transfer of image data is independent of the display unit. This allows future innovations in the area of transfer technology to be implemented using a new Automation Panel Link. Automation Panel 900 user's manual V2.22...
Each device has at least one USB interface on the front and back so that data can be easily exchanged with an industrial PC (e.g. using a UBS flash drive). On display front on back Figure 2: USB interfaces on the Automation Panel (front and back) Automation Panel 900 user's manual V2.22...
The following table lists the specifications for minimum and maximum ambient temperature for all available Au- tomation Panel 900 variants during operation in relation to mounting orientation (for specifications, see "Mounting orientation" on page 115). Automation Panel 900 without Rittal housing Automation Panel Link DVI receiver SDL receiver SDL transmitter...
Technical data 2.2.2.2 Minimum ambient temperature during operation The minimum ambient temperature during operation is 0°C. Automation Panel 900 user's manual V2.22...
Table 5: Overview of humidity specifications for individual components The specifications listed correspond to the relative humidity at an ambient temperature of 30°C. For more detailed information about specific temperature-dependent humidity values, see the technical data for the individual com- ponents. Automation Panel 900 user's manual V2.22...
Technical data 2.2.4 Power consumption Total consumption is made up of the consumption of the Automation Panel 900 device as well as the power used by Automation Panel Link insert card. The following table lists the typical consumption for each component. The sum of both equals the total consumption.
Digital display 98-pin LVDS Connector Inverter Display LVDS Transmitter Touch Touch Controller Fuse RS232 USB A USB A Connector Connector DVI-D RS232 RS232 24 V Backlight Potentiometer Figure 4: AP900 block diagram with DVI Link Automation Panel 900 user's manual V2.22...
(after selecting the "Serial number" option) at the top of the website (www.br-automation.com). The search provides a detailed list of installed components. Serial number entered here e.g. 75170168448 Switching to the option "Serial number" Figure 9: Example of serial number search Automation Panel 900 user's manual V2.22...
• Fan-free operation • Can be upgraded with Display Link cards or PPC300 Front-side USB interface Figure 10: 5AP920.1043-01 - Front view Back-side USB interface Automation Panel Link Insert slot Figure 11: 5AP920.1043-01 - Rear view Automation Panel 900 user's manual V2.22...
Optional accessories Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel); battery; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Page 29
Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). USB devices can only be connected to the Automation Panel directly (without a hub). Depends on the transfer technology, transfer distance and Automation Panel Link plug-in card being used. Automation Panel 900 user's manual V2.22...
Page 31
251.5 Cutout Cutout size 303 ±0.5 mm x 243 ±0.5 mm suitable for 5AP920.1043-01 5AP980.1043-01 Figure 14: 5AP920.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Legend strips for keys for labeling as needed Front-side USB interface Figure 15: 5AP951.1043-01 - Front view Rear USB connection Automation Panel Link insert slot Figure 16: 5AP951.1043-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 33
28 with LED (yellow) Soft keys 10 with LED (yellow) System keys Numeric keys, cursor block Service life >1,000,000 actuations at 1 ±0.3 N to 3 ±0.3 N actuating force Table 10: 5AP951.1043-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 34
The specified value applies to the Automation Panel device with a connected Automation Panel Link plug-in card. The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level. Visual deviations in color and surface quality are possible due to process or batch conditions. Automation Panel 900 user's manual V2.22...
Page 36
349.5 Cutout Cutout size 303 ±0.5 mm x 341 ±0.5 mm suitable for 5AP951.1043-01 5AP981.1043-01 Figure 19: 5AP951.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 37
24 VDC (order screw clamp ter- minal block 0TB103.9 or cage clamp terminal block 0TB103.91 separately). Optional accessories Accessories 5AC900.104X-04 Legend Strips Template 10,4" Automation Panel 5AP952.1043-01 and 5AP982.1043-01; for 1 device. Table 11: 5AP952.1043-01 - Order data Automation Panel 900 user's manual V2.22...
Page 38
2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Transport 2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Table 12: 5AP952.1043-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 39
Visual deviations in color and surface quality are possible due to process or batch conditions. 2.3.1.1.3.4 Temperature humidity diagram Operation Storage (any specified Transport mounting orientation) -80 -70 -60 -50 -40 -30 -20 -10 40 50 Temperature [°C] Figure 22: 5AP952.1043-01 - Temperature humidity diagram Automation Panel 900 user's manual V2.22...
Page 41
279.5 Cutout Cutout size 402 ±0.5 mm x 271 ±0.5 mm suitable for 5AP952.1043-01 5AP982.1043-01 Figure 24: 5AP952.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 42
Front-side USB interface Legend strips for keys for labeling as needed Figure 25: 5AP980.1043-01 - Front view Back-side USB interface Automation Panel Link Insert slot Figure 26: 5AP980.1043-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 43
5AP980.1043-01; for 3 devices. Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel);...
Page 44
Similar to Pantone 427CV Dark border color around display Similar to Pantone 432CV Color slide-in labels Similar to Pantone 429CV Gasket Flat gasket around display front Table 14: 5AP980.1043-01, 5AP980.1043-01, 5AP980.1043-01, 5AP980.1043-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 46
251.5 Cutout Cutout size 303 ±0.5 mm x 243 ±0.5 mm suitable for 5AP920.1043-01 5AP980.1043-01 Figure 29: 5AP980.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 47
Legend strips for keys for labeling as needed Front-side USB interface Figure 30: 5AP981.1043-01 - Front view Rear USB connection Automation Panel Link insert slot Figure 31: 5AP981.1043-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 48
5AP951.1043-01 and 5AP981.1043-01; for 1 device. Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel);...
Page 49
Dark gray keys color Similar to Pantone 431CV Orange keys color Similar to Pantone 151CV Color slide-in labels Similar to Pantone 429CV Gasket Flat gasket around display front Table 16: 5AP981.1043-01, 5AP981.1043-01, 5AP981.1043-01, 5AP981.1043-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 50
Visual deviations in color and surface quality are possible due to process or batch conditions. 2.3.1.1.5.4 Temperature humidity diagram Operation Storage (any specified Transport mounting orientation) -80 -70 -60 -50 -40 -30 -20 -10 40 50 Temperature [°C] Figure 32: 5AP981.1043-01 - Temperature humidity diagram Automation Panel 900 user's manual V2.22...
Page 52
349.5 Cutout Cutout size 303 ±0.5 mm x 341 ±0.5 mm suitable for 5AP951.1043-01 5AP981.1043-01 Figure 34: 5AP981.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 53
Legend strips for keys Front-side USB interface for labeling as needed Figure 35: 5AP982.1043-01 - Front view Rear USB connection Automation Panel Link insert slot Figure 36: 5AP982.1043-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 54
5AP952.1043-01 and 5AP982.1043-01; for 1 device. Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel);...
Page 55
Dark gray keys color Similar to Pantone 431CV Orange keys color Similar to Pantone 151CV Color slide-in labels Similar to Pantone 429CV Gasket Flat gasket around display front Table 18: 5AP982.1043-01, 5AP982.1043-01, 5AP982.1043-01, 5AP982.1043-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 57
279.5 Cutout Cutout size 402 ±0.5 mm x 271 ±0.5 mm suitable for 5AP952.1043-01 5AP982.1043-01 Figure 39: 5AP982.1043-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
• Fan-free operation • Can be upgraded with Display Link cards or PPC300 Front-side USB interface Figure 40: 5AP920.1214-01 - Front view Back-side USB interfaces Automation Panel Link Insert slot Figure 41: 5AP920.1214-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 59
Optional accessories Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel); battery; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Page 60
Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). USB devices can only be connected to the Automation Panel directly (without a hub). Depends on the transfer technology, transfer distance and Automation Panel Link plug-in card being used. Automation Panel 900 user's manual V2.22...
Page 62
Outer contour (Automation Panel) 275.5 Cutout Cutout size 342 ±0.5 mm x 267 ±0.5 mm suitable for 5AP920.1214-01 Figure 44: 5AP920.1214-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
• Fan-free operation • Can be upgraded with Display Link cards or PPC300 Front-side USB interface Figure 45: 5AP920.1505-01 - Front view Back-side USB interfaces Automation Panel Link Insert slot Figure 46: 5AP920.1505-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 64
Optional accessories Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel); battery; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Page 65
Panel overlay Material Polyester Light background color Similar to Pantone 427CV Dark border color around display Similar to Pantone 432CV Gasket Flat gasket around display front Table 22: 5AP920.1505-01, 5AP920.1505-01, 5AP920.1505-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 67
Outer contour (Automation Panel) Cutout Cutout size 415 ±0.5 mm x 312 ±0.5 mm suitable for 5AP920.1505-01 5AP980.1505-01 Figure 49: 5AP920.1505-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 68
Legend strips for keys for labeling as needed Front-side USB interface Figure 50: 5AP951.1505-01 - Front view Rear USB connections Automation Panel Link insert slot Figure 51: 5AP951.1505-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 69
Soft keys 12 with LED (yellow) System keys Alphanumeric keys, numeric keys, cursor block Service life >1,000,000 actuations at 1 ±0.3 N to 3 ±0.3 N actuating force Table 24: 5AP951.1505-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 70
The specified value applies to the Automation Panel device with a connected Automation Panel Link plug-in card. The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level. Visual deviations in color and surface quality are possible due to process or batch conditions. Automation Panel 900 user's manual V2.22...
Page 72
Outer contour (Automation Panel) Cutout Cutout size 415 ±0.5 mm x 412 ±0.5 mm suitable for 5AP951.1505-01 5AP981.1505-01 Figure 54: 5AP951.1505-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 73
Front-side USB interface Legend strips for keys for labeling as needed Figure 55: 5AP920.1505-01 - Front view Back-side USB interfaces Automation Panel Link Insert slot Figure 56: 5AP980.1505-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 74
Panel PC 5PC781.1505-00; for 4 devices. Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel);...
Page 75
Similar to Pantone 427CV Dark border color around display Similar to Pantone 432CV Color slide-in labels Similar to Pantone 429CV Gasket Flat gasket around display front Table 26: 5AP980.1505-01, 5AP980.1505-01, 5AP980.1505-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 77
Outer contour (Automation Panel) Cutout Cutout size 415 ±0.5 mm x 312 ±0.5 mm suitable for 5AP920.1505-01 5AP980.1505-01 Figure 59: 5AP980.1505-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
Page 78
Legend strips for keys for labeling as needed Front-side USB interface Figure 60: 5AP981.1505-01 - Front view Rear USB connections Automation Panel Link insert slot Figure 61: 5AP981.1505-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 79
Panel PC 5PC781.1505-00; for 4 devices. Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel);...
Page 80
Dark gray keys color Similar to Pantone 431CV Orange keys color Similar to Pantone 151CV Color slide-in labels Similar to Pantone 429CV Gasket Flat gasket around display front Table 28: 5AP981.1505-01, 5AP981.1505-01, 5AP981.1505-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 81
Visual deviations in color and surface quality are possible due to process or batch conditions. 2.3.1.3.4.4 Temperature humidity diagram Operation Mounting orientation 0° or -45 -80 -70 -60 -50 -40 -30 -20 -10 40 50 Temperature [°C] Figure 62: 5AP981.1505-01 - Temperature humidity diagram Automation Panel 900 user's manual V2.22...
Page 83
Outer contour (Automation Panel) Cutout Cutout size 415 ±0.5 mm x 412 ±0.5 mm suitable for 5AP951.1505-01 5AP981.1505-01 Figure 64: 5AP981.1505-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
• Fan-free operation • Can be upgraded with Display Link cards or PPC300 Front-side USB interface Figure 65: 5AP920.1706-01 - Front view Back-side USB interfaces Automation Panel Link Insert slot Figure 66: 5AP920.1706-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 85
Optional accessories Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel); battery; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Page 86
Derating the maximum ambient temperature - typically 1°C per 1000 meters (from 500 meters above sea level). Depending on the process or batch, there may be visible deviations in the color and surface structure. Automation Panel 900 user's manual V2.22...
Page 89
381.5 Cutout Cutout size 460 ±0.5 mm x 373 ±0.5 mm suitable for 5AP920.1706-01 468.5 Figure 70: 5AP920.1706-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
• Fan-free operation • Can be upgraded with Display Link cards or PPC300 Front-side USB interface Figure 71: 5AP920.1906-01 - Front view Back-side USB interfaces Automation Panel Link Insert slot Figure 72: 5AP920.1906-01 - Rear view Automation Panel 900 user's manual V2.22...
Page 91
Optional accessories Panel PC 300 insert cards 5PC310.L800-00 Panel PC 300 insert card for the Automation Panel 900; 256 MB SDRAM; CompactFlash slot (Type I); 2x ETH 10/100; RS232; USB 2.0 (via integrated USB 2.0 interfaces on the Automation Panel); battery; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately)
Page 92
Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com). USB devices can only be connected to the Automation Panel directly (without a hub). Depends on the transfer technology, transfer distance and Automation Panel Link plug-in card being used. Automation Panel 900 user's manual V2.22...
Page 95
412.5 Cutout Cutout size 510 ±0.5 mm x 404 ±0.5 mm suitable for 5AP920.1906-01 518.5 Figure 76: 5AP920.1906-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
SDL Out, transfer of display data, touch screen, USB 1.1, matrix keys and, service data, 24 VDC (order screw clamp ter- minal block 0TB103.9 or cage clamp terminal block 0TB103.91 separately). Table 33: 5AP920.2138-01 - Order data Automation Panel 900 user's manual V2.22...
Page 97
2 to 8 Hz: 7.5 mm amplitude / 8 to 200 Hz: 2 g / 200 to 500 Hz: 4 g Shock Operation 15 g, 11 ms Storage 30 g, 15 ms Transport 30 g, 15 ms Elevation Operation Max. 3000 m Table 34: 5AP920.2138-01 - Technical data Automation Panel 900 user's manual V2.22...
Page 98
Visual deviations in color and surface quality are possible due to process or batch conditions. 2.3.1.6.1.4 Temperature humidity diagram Operation Mounting orientation 0° or -45 -80 -70 -60 -50 -40 -30 -20 -10 40 50 Temperature [°C] Figure 79: 5AP920.2138-01 - Temperature humidity diagram Automation Panel 900 user's manual V2.22...
Page 100
455.5 Cutout Cutout size 566 ±0.5 mm x 447 ±0.5 mm suitable for 5AP920.2138-01 574.5 Figure 81: 5AP920.2138-01 - Cutout installation For additional information regarding installation and mounting orientation, see "Commissioning" on page 114. Automation Panel 900 user's manual V2.22...
B&R Industrial PC (e.g. Automation PC 810) via the cable. A plug-in card is simply inserted into the Automation Panel 900 slot provided and fastened into place using the two locating screws (max. tightening torque 0.5 Nm).
This type of transfer supports the transmission of display data, USB 2.0 data and touch screen data over separate cables for each. • Can be used in all Automation Panel 900 devices • DVI-D, RS232 and USB 2.0 connections 2.3.2.1.2 Order data...
Page 103
USB Type B connector Figure 84: Comparison of USB Type A/B connectors If the Display Link is connected correctly, then the Automation Panel 900 is equipped with one or more (depending on the type) USB ports (front and back). Information: USB 2.0 is supported for cables up to 5 meters in length.
Page 104
Technical data 2.3.2.1.4.4 COM Serial interface The RS232 interface is used to transfer signals from the Automation Panel 900 touch screen. B&R offers RS232 cables up to 10 meters in length (see "Cables" on page 157). COM serial interface RS232...
1.1 is fully integrated in SDL and transferred over this distance as well without the need for external modules. A panel can be operated on a line using an SDL receiver. • Can be used in all Automation Panel 900 devices • SDL IN connections 2.3.2.2.2 Order data...
Page 106
2.3.2.2.4.3 Panel IN This interface is intended for the SDL connection to a B&R Industrial PC. The necessary SDL cables are available separately from B&R (see "Cables" on page 157). Automation Panel 900 user's manual V2.22...
To achieve the maximum segment length, it is possible to use cables with an integrated extender that acts as an amplifier. Additional hardware is not required. • Can be used in all Automation Panel 900 devices • SDL IN and SDL OUT connections 2.3.2.3.2 Order data...
Page 108
B&R (see "Cables" on page 157). 2.3.2.3.4.4 Panel OUT This interface is intended for the SDL connection to an additional Automation Panel 900 device. The necessary SDL cables are available separately from B&R (see "Cables" on page 157).
✓ SDL3 interface USB1, USB2 USB 2.0 Power supply Grounding Maximum cable length for SDL3: 100 m Requirements • Automation Panel with SDL3 receiver • B&R industrial PC with SDL3 interface • SDL3/SDL4 cable Automation Panel 900 user's manual V2.22...
Page 110
The specified value refers to an Automation Panel Link plug-in card connected in a 19" Automation Panel device. 2.3.2.4.4 Interfaces 2.3.2.4.4.1 SDL3 In interface The "SDL3 In" interface is a female RJ45 connector and operated with SDL3 transmission technology. For addi- tional information, see section "SDL3 operation" on page 109. Automation Panel 900 user's manual V2.22...
Page 111
The male panel connector is specified for 500 connection cycles. Information: If a display device with a touch screen is connected to the panel interface and then disconnected again during operation (hot-plugging), it may be necessary to recalibrate the touch screen. Automation Panel 900 user's manual V2.22...
Page 112
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Each USB interface is protected by a maintenance-free "USB current-limiting circuit breaker" (total max. 500 mA). Automation Panel 900 user's manual V2.22...
A hex key (3 mm) is needed to tighten and loosen the screws. The maximum torque when tightening the clamp is 0.5 Nm. Devices must be installed on flat, clean and burr-free surface; uneven areas can cause damage to the display when the screws are tightened or intrusion of dust and water. Automation Panel 900 user's manual V2.22...
Commissioning 3.2 Mounting orientation The following diagrams show the approved mounting orientations for the Automation Panel 900. 3.2.1 Mounting orientation 0° Side with connections facing down! Figure 88: Mounting orientation 0° 3.2.2 Mounting orientation 45° Side with connections facing down! Side with connections facing down! Figure 89: Mounting orientations -45°...
Air inlet Figure 90: Spacing for air circulation - Side view At least At least 10 mm spacing 10 mm spacing Side with connections facing down! Figure 91: Spacing for air circulation - Rear view Automation Panel 900 user's manual V2.22...
This grounding clip (functional ground) must be connected to a central grounding point on the control cabinet using a 6.3 mm tab connector and the shortest possible path with the least resistance possible (e.g. copper strip, at least 2.5 mm²). Figure 93: Functional grounding clip Automation Panel 900 user's manual V2.22...
(www.br-automation.com). The B&R Control Center uses the B&R Automation Device Interface (ADI). A separate application can be developed if it is necessary to collect historical data. Information: Software development kits such as the ADI .NET SDK are available on the B&R website (www.br-au- tomation.com). Automation Panel 900 user's manual V2.22...
Loopback plugs are also available from Passmark. More information is available at www.pass- mark.com. The following screenshots are based on Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD. Figure 94: Settings for Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD Automation Panel 900 user's manual V2.22...
Page 120
Windows. The test USB must then be deselected, and the USB flash drives must be configured as the testing device in the disk properties. Information: Serial loopback plugs are relatively easy to create. Simply connect several pins on the serial interface with wires. Automation Panel 900 user's manual V2.22...
3.7.1 Selecting display units In order to connect an Automation Panel 800 and an Automation Panel 900 on the same line, the devices must have the same display type. The following table lists the AP900 devices that can be connected on the same line with an AP800 device.
A separate cable is used for both the touch screen and USB data. If USB devices are to be operated on the Automation Panel 900, the maximum distance is 5 meters. USB devices can only be connected directly to the Automation Panel (i.e.
5 m / 10 m Table 55: Possible Automation Panel devices, resolutions and segment lengths USB support is not possible on the Automation Panel 900 in these cases since USB is limited to 5 m. Information: When transferring data via DVI, it is not possible to read statistical values from Automation Panel 900 devices.
3.7.3 One Automation Panel 900 system via onboard SDL An Automation Panel 900 is connected to the integrated SDL interface (onboard) via an SDL cable. USB devices can only be connected directly to the Automation Panel (i.e. without a hub).
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation Panel 900 user's manual V2.22...
3.7.4 Four Automation Panel 900 systems via onboard SDL An Automation Panel 900 is connected to the integrated SDL interface (onboard) via an SDL cable. Up to three other Automation Panels of the same type are connected to this Automation Panel and operated via SDL. All four of the panels show the same content (display clone).
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation Panel 900 user's manual V2.22...
Commissioning 3.7.5 One Automation Panel 900 via SDL3 One Automation Panel 900 is connected to the optional SDL3 interface via an SDL3 cable. USB devices can only be connected directly to the Automation Panel (i.e. without a hub). Monitor/Panel Option SDL3 segment Max.
Page 130
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Automation Panel 900 user's manual V2.22...
Many different peripheral USB devices can be connected to the 2 or 3 USB interfaces on the Automation Panel 900. These can each handle a load of 500 mA. The maximum transfer rate is USB 2.0. Information: Only end devices (not hubs) can be connected to the Automation Panel 900. USB 2.0 USB 2.0...
3.8.2 Remote connection to Automation Panel 800 / 900 via SDL Many different peripheral USB devices can be connected to the 2 or 3 USB interfaces on Automation Panel 900 or the USB interfaces on Automation Panel 800 devices. These can each handle a load of 500 mA. The maximum transfer rate is USB 1.1.
Many different peripheral USB devices can be connected to the 2 or 3 USB interfaces on the Automation Panel 900. These can each handle a load of 500 mA. The maximum transfer rate is USB 2.0. Information: Only end devices (not hubs) can be connected to the Automation Panel 900. SDL3 (USB 2.0) USB 2.0 USB memory media e.g.
The images below show the positions of keys and LEDs in the matrix. This information is indicated as follows. Hardware number of LED Hardware number of key Hardware number of LED Hardware number of key Key without LED Key with LED Figure 104: Keys and LEDs in the matrix Automation Panel 900 user's manual V2.22...
On all other devices, the touch screen driver must be subsequently installed to operate the touch screen. The appropriate driver is available for download in the Downloads section of the B&R website (www.br-automation.com). Automation Panel 900 user's manual V2.22...
• Use complementary colors for subsequent images. • Use screensavers. 3.12 Pixel errors Information: Displays can contain faulty pixels (pixel errors) due to the manufacturing process. They are not grounds for initiating a complaint or warranty claim. Automation Panel 900 user's manual V2.22...
• Reading temperatures, fan speeds, statistical data and switch settings • Reading operating hours (power-on hours) • Reading user and factory settings • Reading software versions • Updating and backing up BIOS and firmware • Creating reports about the current system (support assistance) Automation Panel 900 user's manual V2.22...
The ADI driver is already included in B&R images of embedded operating systems. If a more current ADI driver version exists (see the Downloads section of the B&R website), it can be installed later. It is important that Enhanced Write Filter (EWF) is disabled for this. Automation Panel 900 user's manual V2.22...
• Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 • Power Panel 100/200 • Power Panel 300/400 • Power Panel 500 Automation Panel 900 user's manual V2.22...
Page 143
A detailed description of how to use ADI functions can be found in the help system. The B&R Automation Device Interface (ADI) development kit is available at no cost in the Downloads section of the B&R website (www.br-automation.com). Automation Panel 900 user's manual V2.22...
• Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 • Power Panel 100/200 • Power Panel 300/400 • Power Panel 500 Automation Panel 900 user's manual V2.22...
Page 145
B&R images of embedded operating systems. A detailed description of how to use ADI functions can be found in the help system. The ADI .NET SDK is available in the Downloads section of the B&R website (www.br-automation.com). Automation Panel 900 user's manual V2.22...
• Assignment of functions to LEDs (HDD access, power, etc.) • 4 assignments possible per key (using layers) • Configuration of the panel locking time when multiple Automation Panel 900 devices are connected to Automation PC and Panel PC devices.
Page 147
A detailed guide for configuring keys and LEDs can be found in the B&R Key Editor's help system. The B&R Key Editor is available at no cost in the Downloads section of the B&R website (www.br-automation.com). It can also be found on the B&R HMI Drivers & Utilities DVD (model number 5SWHMI.0000-00). Automation Panel 900 user's manual V2.22...
These devices satisfy the requirements of EC directive "2006/95/EC Low voltage directive" and are designed for the following areas: EN 61131-2:2007 Programmable logic controllers - Part 2: Equipment requirements and tests EN 60204-1:2006 + Safety of machinery - Electrical equipment of machines - Part 1: General requirements A1:2009 Automation Panel 900 user's manual V2.22...
Eurasian Customs Union (based on EU conformity). 5.2.3 KC Products with this mark are tested by an accredited test laboratory and permitted to be introduced into the Korean market (based on EU conformity). Automation Panel 900 user's manual V2.22...
• Touch screen functionality • USB mouse functionality • Hot plugging functionality tested by disconnecting the USB cable • After a test duration of 150,000 cycles, testing was concluded with a result of "OK". Automation Panel 900 user's manual V2.22...
• Touch screen functionality • USB mouse functionality • Hot plugging functionality tested by disconnecting the USB cable • After a test duration of 300,000 cycles, testing was concluded with a result of "OK". Automation Panel 900 user's manual V2.22...
All components listed in this manual have undergone intensive system and compatibility testing and been approved accordingly. B&R cannot assume any functional warranty for accessories that have not been approved. Automation Panel 900 user's manual V2.22...
Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for the product family. The cage clamp terminal block cannot be used side by side. The respective limit data of the I/O modules must be taken into account! Automation Panel 900 user's manual V2.22...
Electrical properties Nominal voltage 300 V Nominal current 10 A / contact Contact resistance ≤5 mΩ Table 69: 0TB103.8 - Technical data The limit data for each I/O module must be taken into consideration. Automation Panel 900 user's manual V2.22...
≥5x cable diameter (male connector - ferrite bead and ferrite bead - ferrite bead) Weight Approx. 260 g Approx. 460 g Approx. 790 g Table 72: 5CADVI.0018-00, 5CADVI.0050-00, 5CADVI.0100-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification. Automation Panel 900 user's manual V2.22...
Page 159
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. DVI-D (24+1), male DVI-D (24+1), male Cable shield Cable shield Figure 118: 5CADVI.0xxx-00 - Pinout Automation Panel 900 user's manual V2.22...
Approx. 1500 g Approx. 2250 g Approx. 2880 g Approx. 4800 g Approx. 5520 g Table 74: 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0100-00, 5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification. Automation Panel 900 user's manual V2.22...
Page 162
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 121: 5CASDL.0xxx-00 - Pinout Automation Panel 900 user's manual V2.22...
Approx. 300 g Approx. 590 g Approx. 2800 g Approx. 2860 g Table 76: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01, 5CASDL.0150-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification. Automation Panel 900 user's manual V2.22...
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 124: 5CASDL.0xxx-01 - Pinout Automation Panel 900 user's manual V2.22...
Oil and hydrolysis resistance In accordance with VDE 0282-10 Environmental conditions Temperature Storage -20 to 60°C Fixed installation -20 to 60°C Flexible installation -5 to 60°C Table 81: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data Automation Panel 900 user's manual V2.22...
Page 171
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 130: 5CASDL.0xx0-13 - Pinout Automation Panel 900 user's manual V2.22...
Page 172
• Connect the end labeled "SDL IN" with the video output of the APC910 (monitor/panel output) or Panel OUT of an AP900 AP Link card. • Connect the "SDL OUT" end to the display unit (e.g. Automation Panel 900) via the Automation Panel Link plug-in card (Panel IN).
IP20, only when connected properly Environmental conditions Temperature Storage -40 to 70°C Fixed installation -40 to 70°C Flexible installation -40 to 70°C -10 to 50°C Table 83: 5CASD3.0100-00, 5CASD3.0150-00, 5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data Automation Panel 900 user's manual V2.22...
Page 174
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. Pinout per TIA/EIA 568A wh/gn wh/or wh/bl wh/br Shield Figure 135: 5CASD3.xxxx-00 - Pinout Automation Panel 900 user's manual V2.22...
Page 175
100 m is not permitted. B&R device Patch panel Patch panel B&R device Patch cable Field-assembled cable Patch cable Max. 5 m Max. 5 m Max. 100 m Figure 136: Wiring with a field-assembled cable Automation Panel 900 user's manual V2.22...
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. USB type A, male USB type B, male Jacket Jacket Figure 137: 5CAUSB.00xx-00 USB cables - Pinout Automation Panel 900 user's manual V2.22...
Max. 0.5 Nm Mechanical characteristics Dimensions Length 1.8 m ±50 mm 5 m ±80 mm 10 m ±100 mm Diameter Max. 5 mm Flex radius Min. 70 mm Table 87: 9A0014.02, 9A0014.05, 9A0014.10 - Technical data Automation Panel 900 user's manual V2.22...
Page 178
If a field-assembled cable is used, B&R cannot guarantee its functionality. Functionality is only guar- anteed for the cables available from B&R. DSUB (9-pin), male DSUB (9-pin), female Pin assignments DSUB (9-pin), male DSUB (9-pin), female Shield Shield Automation Panel 900 user's manual V2.22...
USB interface cover - Flat - For AP920/98x and PPC700 Table 89: 5AC900.1200-01 - Order data 6.5.3 5AC900.1201-00 6.5.3.1 General information Flat front-side USB interface cover for Automation Panel 900, Power Panel 500, Panel PC 700 and Panel PC 800 devices. 6.5.3.2 Order data Order number...
Accessories 6.5.4 5AC900.1201-01 6.5.4.1 General information Round front-side knurled USB interface cover (with anti-loss strap) for Automation Panel 900, Power Panel 500, Panel PC 700 and Panel PC 800 devices. 6.5.4.2 Order data Order number Short description Figure Accessories 5AC900.1201-01 USB interface cover M20 IP65 curved Table 91: 5AC900.1201-01 - Order data...
Operating systems Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Current consumption 650 µA sleep mode, 150 mA read/write Table 93: 5MMUSB.2048-00 - Technical data Automation Panel 900 user's manual V2.22...
Width 19 mm Length 52.2 mm Height 7.9 mm Table 93: 5MMUSB.2048-00 - Technical data Indicates data being transferred (sending and receiving). 6.6.1.4 Temperature/Humidity diagram Operation Temperature [°C] Figure 138: 5MMUSB.2048-00 - Temperature/Humidity diagram Automation Panel 900 user's manual V2.22...
Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Current consumption Max. 500 μA sleep mode, max. 120 mA read/write Table 95: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Automation Panel 900 user's manual V2.22...
Length 67.85 mm Height 8.35 mm Table 95: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Indicates data being transferred (sending and receiving). 6.6.2.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 139: 5MMUSB.xxxx-01 - Temperature/Humidity diagram Automation Panel 900 user's manual V2.22...
(see 2 "Technical data" on page 17). Fluorescent tubes can only be replaced on 12.1" and 15" Automation Panel 900 devices. Information: They cannot be replaced on 10.4", 17", 19" and 21.3" Automation Panel 900 devices! The following table lists the fluorescent tubes that can be used for each panel.
Overvoltage category per EN 61131-2 Operating conditions Pollution degree per EN 61131-2 Pollution degree 2 Ambient conditions Temperature Operation -25 to 65°C Storage -25 to 65°C Transport -25 to 65°C Mechanical properties Housing Material Galvanized plate Automation Panel 900 user's manual V2.22...
• Keep the lines as short as possible (power supply - line filter - end device). • The line filter must be installed on an uncoated, oil-free metallic surface. Line filter End device Figure 142: Connection example Automation Panel 900 user's manual V2.22...
• Power Panel 300/400 BIOS user boot logo • Power Panel 500 / Automation PC 510 / Automation PC 511 BIOS • Panel PC 310 Driver for the devices • Automation Device Interface (ADI) • Audio • Chipset • CD-ROM Automation Panel 900 user's manual V2.22...
Page 189
• Windows CE 4.2 • Windows CE 4.1 • Windows CE tools • Windows Embedded Standard 2009 • Windows Embedded Standard 7 • Thin client • Windows NT Embedded • Windows XP Embedded • VNC viewer Automation Panel 900 user's manual V2.22...
Page 190
• Acrobat Reader 5.0.5 (freeware in German, English and French) • Power Archiver 6.0 (freeware in German, English and French) • Internet Explorer 5.0 (German and English) • Internet Explorer 6.0 (German and English) Automation Panel 900 user's manual V2.22...
Apply the cleaning agent to the cloth first; do not spray it directly onto the device! Never use aggressive solvents, chemicals, abrasive cleaners, compressed air or steam cleaners. Information: Displays with a touch screen should be cleaned at regular intervals. Automation Panel 900 user's manual V2.22...
Servicing and maintenance 7.2 Replacing the fluorescent tubes Danger! Fluorescent tubes may only be replaced by qualified personnel when the Automation Panel 900 device and the entire system are both switched off. 7.2.1 Procedure First step for all units (12.1" and 15"): Remove the cover. Remove the locating screws (1) and insert the card (2).
Figure 144: Warning - Replacing the fluorescent tubes 7.2.1.2 Procedure for 12.1" Automation Panels • Using a small Phillips screwdriver, remove the screws and disconnect the fluorescent tube. Figure 145: 12.1" Automation Panels - Unscrewing and disconnecting Automation Panel 900 user's manual V2.22...
• Unplug the fluorescent tube (1). Remove the screws (2) from the fluorescent tubes using a small Phillips screwdriver, and remove the ground (3) from the housing using a size 10 Torx screwdriver. Figure 147: 15" Automation Panels - Unscrewing and disconnecting Automation Panel 900 user's manual V2.22...
Page 195
Figure 148: 15" Automation Panels - Removing the cover and disconnecting • Replace the fluorescent tubes. To do this, carefully pull the tubes out of their holders and replace them with new ones. Figure 149: 15" Automation Panel - Replacing the fluorescent tubes Automation Panel 900 user's manual V2.22...
Electronics recycling Operating and monitoring devices Uninterruptible power supplies Batteries and rechargeable batteries Cables Paper/Cardboard packaging Paper/Cardboard recycling Plastic packaging material Plastic recycling Disposal must be carried out in accordance with applicable legal regulations. Automation Panel 900 user's manual V2.22...
The active area of the touch screen is resistant to these chemicals for a period of one hour at 21°C. A.1.2 Temperature humidity diagram Storage Operation Temperature [°C] Figure 150: Elo AccuTouch screen (5-wire) - Temperature humidity diagram Automation Panel 900 user's manual V2.22...
Apply the cleaning agent to the cloth first; do not spray it directly onto the device! Never use aggressive solvents, chemicals, abrasive cleaners, compressed air or steam cleaners. Information: Displays with a touch screen should be cleaned at regular intervals. Automation Panel 900 user's manual V2.22...
Use a damp cloth to clean the device. Use only water with detergent, screen cleaner or alcohol (ethanol) to moisten the cleaning cloth. Apply the cleaning agent to the cloth first; do not spray it directly onto the device! Never use aggressive solvents, chemicals, abrasive cleaners, compressed air or steam cleaners. Automation Panel 900 user's manual V2.22...
Page 200
Appendix A Information: Displays with a touch screen should be cleaned at regular intervals. Automation Panel 900 user's manual V2.22...
Abrasion-resistant in accordance with DIN 52347 Adhesive strength in accordance with DIN 58 196-K2 (Part 6) Chemical properties Durability according to DIN 50021 - CASS Automation Panel 900 user's manual V2.22...
Appendix A A.5 Viewing angles For viewing angle specifications (R, L, U, D) of the display types, see the technical data of the individual compo- nents. 6 o'clock direction Automation Panel 900 user's manual V2.22...
A.6 Mounting compatibility This section describes the compatibility of the installation dimensions for Power Panel 100/200, Power Panel 300/400, Power Panel 500, Automation Panel 900, Automation Panel 700 and Panel PC 800 devices according to device display size. The outer dimensions of the device types are identical for the respective display sizes.
Outer contour of device Cutout for device Figure 154: Mounting compatibility - 5.7" device - Horizontal2 5.7" Power Panel 500 devices and Power Panel 100/200300/400 devices are 100% mounting compatible in the Horizontal2 format. Automation Panel 900 user's manual V2.22...
Outer contour of device Cutout for device Figure 156: Mounting compatibility - 10.4" device - Horizontal1 10.4" Power Panel 500 devices and Power Panel 100/200/300/400 devices are 100% mounting compatible in the Horizontal1 format. Automation Panel 900 user's manual V2.22...
Page 206
Figure 157: Mounting compatibility - 10.4" device - Horizontal2 10.4" Power Panel 500, Automation Panel 900 and Panel PC 700 devices are not 100% mounting compatible with Power Panel 100/200/300/400 devices in the Horizontal2 format. The Power Panel 500, Automation Panel 900 and Panel PC 700 devices require a cutout that is 4.5 mm higher (bottom edge).
Figure 159: Mounting compatibility - 12.1" device - Horizontal1 12.1" Power Panel 500, Automation Panel 900 and Panel PC 700 devices are not 100% mounting compatible with Power Panel 100/200/300/400 devices in Horizontal1 format. The Power Panel 300/400 and Power Panel 100/200 devices require a cut that is 1.5 mm wider (left and right).
Outer contour of device Cutout for device Figure 163: Mounting compatibility - 19" device - Horizontal1 19" Automation Panel 900, Panel PC 700 and Panel PC 800 are 100% mounting compatible in the Horizontal1 format. A.6.2.8 21.3" devices 583 x 464 566 x 447 ±0.5...
Need help?
Do you have a question about the Automation Panel 900 and is the answer not in the manual?
Questions and answers