IMPORTANT DOCUMENTS ENCLOSED
CAUTION:
To reduce the risk of injury due to hot water
burns, make sure the enclosed labels are
applied where specified on the label.
DOCUMENTOS IMPORTANTES INCLUIDOS
AVISO:
Para reducir el riesgo de lesión por
quemaduras de agua caliente , asegúrese que
las etiquetas incluidas se han aplicado donde
se ha especificado en la etiqueta.
DOCUMENTS IMPORTANTS À L'INTÉRIEUR
MISE EN GARDE :
Pour réduire le risque d'ébouillantage, veuillez
apposer les étiquettes fournies aux endroits
indiqués sur celles-ci.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MultiChoice 13 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta MultiChoice 13 Series

  • Page 1 IMPORTANT DOCUMENTS ENCLOSED CAUTION: To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label. DOCUMENTOS IMPORTANTES INCLUIDOS AVISO: Para reducir el riesgo de lesión por quemaduras de agua caliente , asegúrese que las etiquetas incluidas se han aplicado donde se ha especificado en la etiqueta.
  • Page 2 (such as when a dishwasher or washing machine is in use with this valve or call 1-800-345-DELTA. These valve series are designed to minimize the effects of while you are taking a shower). After installation, verify that the rotational limit stop or outlet water temperature changes due to inlet pressure changes, commonly caused by dishwashers, washing machines, toilets and the like.
  • Page 3 6 and if still uncertain, call us at WARNING: Do not install a shut-off device on 1-800-345-DELTA. either outlet of this valve. When this type of device shuts off the water flow, it can defeat...
  • Page 4 ® MultiChoice Rough-In Installation (When your product requires) SHUT OFF WATER SUPPLIES. finished wall. Consider the type and thickness of your • Mount body using the two stringer finished wall before placing your stringer mounting holes (4) on the bracket. back plate.
  • Page 5 Copper Tubing Iron Pipe • Connect valve body to water supplies using If you are making a BACK TO BACK the proper fittings for your valve body type OR REVERSE INSTALLATION (hot on (copper tubing, iron pipe or Pex). Note: (1) right and cold on left) install the valve is the cold inlet port and (2) is the hot body as described, but the water supply...
  • Page 6 • Connect top outlet (1) to shower pipe with proper fittings. • Connect bottom outlet (2) to tub spout pipe with proper fittings. • Pipe (3) between valve body and tub spout must be a minimum of 1/2" (13 mm) copper pipe or 1/2"...
  • Page 7 Cartridge Installation Rotate valve cartridge (1) so the words Turn off water supplies. Remove bonnet “HOTTER COLDER” (2) appear on the top. nut (1) and test cap (2) from the body. If Insert cartridge assembly into rough-in body. this is not a thin wall mounting, the entire A light coating of plumbers grease applied to plasterguard (3) may be removed.
  • Page 8 Installation Shower Head and Tub Spout Installation FOR SHOWER HEAD INSTALLATION: Connect top outlet (1) to shower arm (2) with proper fittings. To prevent damage to finish on shower arm, insert wall end of shower arm into shower flange (3) before screwing arm into riser connection.
  • Page 9 FOR TUB SPOUT INSTALLATION: Refer to the installation instructions supplied with your spout. Do not connect deck mount spouts to in-wall valves. Do not use hand showers connected in lieu of a tub spout to a tub/shower valve. Do not use PEX tubing for tub spout drop.
  • Page 10 Adjusting the Rotational Limit Stop -For RLS With Removable Disc Hotter Disc Stem 1st Position IMPORTANT: The Rotational Limit Stop is used to limit the a comfortable bath or shower is typically amount of hot water available such that, if set between 90°F - 110°F.
  • Page 11 -For RLS With Pull/Turn Adjustment Hotter Cooler RLS with pull/turn adjustment IMPORTANT: The Rotational Limit Stop is used to limit the a comfortable bath or shower is typically between 90°F - 110°F. amount of hot water available such that, if set properly, a scald injury is less likely to occur if the •...
  • Page 12 Slide the sleeve over the cartridge, body and O-ring. Note: Adust for up to 1" thick wall. For thick wall installation, visit delta faucet website, check "view technical specification" of the models you bought, order the appropriate thick wall installation kit RP to get additional 1 3/4"...
  • Page 13 Install adapter (1) on cartridge stem (6) with screw (2). Thread set screw (4) into handle (3) slightly, put handle (3) on adapter (1) , hold and adjust the handle (3) at OFF position to ensure it well aligned with sleeve (7). Then tighten set screw (4).
  • Page 14 Cartridge Summary Reference Sheet ® Monitor Series 1300/1400 Cartridge shipped in July 2006 and after Cartridge shipped before March 2006. ® (prior to MultiChoice transition). Shorter lower Shorter lower housing housing White White Blue or off-white Blue Order RP19804 to replace cartridge. Order RP19804 to replace cartridge.