Download Print this page
GE GXRV40TBN 00 Owner's Manual & Installation Instructions
GE GXRV40TBN 00 Owner's Manual & Installation Instructions

GE GXRV40TBN 00 Owner's Manual & Installation Instructions

Reverse osmosis filtration system

Advertisement

Quick Links

SAFETY INFORMATION
Specifications and Dimensions . . . . . . . . . . . . . 5
Performance Data . . . . . . . . . . . . . . . . . . . . . 6-8
Arsenic Facts . . . . . . . . . . . . . . . . . . . . . . . . . . 9
USING THE REVERSE
OSMOSIS SYSTEM
Tools and Materials Required . . . . . . . . . . . . . 12
Before Beginning Installation . . . . . . . . . . . . . 13
Plan the Installation. . . . . . . . . . . . . . . . . . . . . 14
Feed Water Supply . . . . . . . . . . . . . . . . . . . . . 15
Drain Adapter . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connect Tubes (GXRV40TBN 00) . . . . . . . . . 20
Connect Tubes (GXRV40TBN 01) . . . . . . . . . 24
Sanitize the System . . . . . . . . . . . . . . . . . . . . 26
Test and Purge the System. . . . . . . . . . . . . . . 27
Drain Flow Control . . . . . . . . . . . . . . . . . . . . . 32
PARTS LIST
Parts List (GXRV40TBN 00) . . . . . . . . . . . . . . 34
Parts List (GXRV40TBN 01) . . . . . . . . . . . . . . 36
NSF International against NSF/ANSI
the performance data on pages 6-8.
System tested and certified to CSA
the performance data on pages 6-9.
Write the model and serial numbers here:
Model # ___________________________
Serial # ___________________________
You can find them on the bracket.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
. . . . . . . . . . 3
. . . . . . . . . . . . . . 10
. . . . . . 33
. . . . . . . . . . . . . . . . . . . . . . 38
. . . . . . . . . 40
System tested and certified by
Standards 42 and 58 for the
reduction of claims as specified in
B483.1 and NSF/ANSI/CAN 372
System certified by IAPMO R&T
against NSF/ ANSI Standards
42, 53, 58, 401 and P231 for the
reduction of claims as specified in
OWNER'S MANUAL
& INSTALLATION
GXRV40TBN 01
ENGLISH
49-6000285 Rev. 2 1-25 GEA
7392741 Rev. J

Advertisement

loading
Need help?

Need help?

Do you have a question about the GXRV40TBN 00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GE GXRV40TBN 00

  • Page 1: Table Of Contents

    PARTS LIST Parts List (GXRV40TBN 00) ....34 Parts List (GXRV40TBN 01) ....36 WARRANTY .
  • Page 2 THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME. Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family. We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too.
  • Page 3: Safety Precautions

    Intended use: The GE Appliances Reverse Osmosis system is intended for use in filtering potable water in Residential applications, and has not been evaluated for other uses. The system is typically installed at the point of use, and must be installed as specified in the installation instructions.
  • Page 4 • However, additional materials will be required. See parts list to obtain additional materials from GE Appliances. • Locating the tank on a basement floor, with the faucet at a first floor sink may result in some loss of flow rate and capacity (approximately 20%).
  • Page 5: Specifications

    Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant performance. Dimensions: Model Model GXRV40TBN 00 GXRV40TBN 01 14" 14” 10-1/2”...
  • Page 6: Performance Data

    FQ18MN, GXRV40TBN 20.35% 8.94% FQ18PN, FQ18RT (275 - 689 kPa) (5 - 38 °C) (46.2 liters/day) Manufactured by: GE Appliances Louisville, KY 40225 800.952.5039 (US) NSF/ANSI Standard 42 Minimum Reduction Overall % Reduction Results Chlorine Taste & Odor <0.5 mg/L 97.5%...
  • Page 7 Specifications Influent Challenge Maximum Permissible Overall % Results NSF/ANSI Standard 401 Concentration Concentration Reduction Atenolol 200 ng/L ±20% 30 ng/L 99.5% Pass Bisphenol A 2,000 ng/L ±20% 300 ng/L 97.7% Pass Carbamazepine 1,400 ng/L ±20% 200 ng/L 96.3% Pass DEET 1,400 ng/L ±20% 200 ng/L 99.2%...
  • Page 8 Specifications VOCs (by surrogate testing Influent Challenge Maximum Permissible using chloroform) Concentration Concentration Heptachlor 25 g/L 0.01 g/L Heptachlor Epoxide 10.7 g/L 0.2 g/L Hexachlorobutadiene 44 g/L 1.0 g/L Hexachlorocyclopentadiene 60 g/L 0.002 g/L Lindane 55 g/L 0.01 g/L Methoxychlor 50 g/L 0.1 g/L Pentachlorophenol...
  • Page 9: Arsenic Facts

    Specifications Compounds certified under NSF/ANSI 401 have been deemed as ‘incidental contaminants / emerging compounds.’ Incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality.
  • Page 10 Using the Reverse Osmosis System How the Reverse Osmosis System Works Reverse Osmosis reduces Total Dissolved Solids (TDS) and organic matter from water by diffusing it through a special membrane. The membrane separates minerals and impurities from the water and they are flushed to the drain.
  • Page 11 Using the Reverse Osmosis System PRODUCT WATER FAUCET Air Gap PRODUCT WATER BLUE Gravity Drain DRAIN WATER REMINERALIZATION/ ANTIMICROBIAL Drain Flow AUTOMATIC Check FILTER Control SHUTOFF Valve WATER BLUE GREEN PRODUCT PREFILTER POSTFILTER WATER STORAGE TANK YELLOW MEMBRANE Reverse Osmosis Water Flow Schematic Water Flow Description 1.
  • Page 12: Installation Instructions

    Reverse Osmosis Filtration System Instructions Model GXRV40TBN Questions? Call 800.952.5039 (US) or visit our Website at: GEAppliances.com/ge/service-and-support/contact.htm Read entire manual. Failure to follow all guides and rules could cause WARNING personal injury or property damage. Check with your state and/or local public works department for plumbing codes. You must follow their guides as you install the Reverse Osmosis system.
  • Page 13: Before Beginning Installation

    Installation Instructions THINGS TO CHECK BEFORE BEGINNING INSTALLATION FEED WATER RO FAUCET The water supply to the Reverse Osmosis system The RO product water faucet installs on the sink or must have the qualities listed in the specifications. on the countertop next to the sink. It may be Municipal water supplies most often will have installed in an existing sink spray attachment hole, these qualities.
  • Page 14: Plan The Installation

    Installation Instructions PLAN THE INSTALLATION The Reverse Osmosis System can be installed under a sink or in a remote location. Typical remote sites are a laundry room or utility room. Review the location options below and determine where to install the system. UNDER THE SINK LOCATION Drain Adapter Reverse...
  • Page 15: Feed Water Supply

    Installation Instructions FEED WATER SUPPLY Check and comply with local plumbing codes as you plan, then install a cold water supply fitting. A. PREFERRED INSTALLATION B. OPTIONAL INSTALLATION A typical connection using the included water A typical connection using a compression type supply fitting is shown in the illustration below.
  • Page 16: Drain Adapter

    Installation Instructions REVERSE OSMOSIS DRAIN ADAPTER (for under sink installation) INTRODUCTION INSTALL DRAIN ADAPTER (Cont.) A suitable drain point is needed for the drain water from the Reverse Osmosis system. Options are: Faucet • Install the included Drain Adapter As shown below, install the included drain adapter onto the sink’s drain pipe above the P- trap.
  • Page 17 Installation Instructions ALTERNATIVE DRAIN INSTALLATION (for a remote location) Outside Faucet BLUE Tubing Outside Faucet (Hard Water) to R.O. (Hard Water) Faucet Soft, Cold Water Remineralization/ Antimicrobial Filter Soft, Hot Water Soft Water - Shutoff GREEN Tubing Valve to R.O.System Reverse Osmosis System Reverse Osmosis...
  • Page 18: Storage Tank And Faucet (Gxrv40Tbn 00)

    Installation Instructions (Model GXRV40TBN 00) STORAGE TANK AND FAUCET STORAGE TANK INSTALLATION INSTALL THE FAUCET (Cont.) 1. Apply thread sealing tape (2 wraps clockwise) to 1. If drilling is needed, drill a 1-3/8" diameter hole the threads on the nipple at the top of the tank.
  • Page 19: Remineralization/Antimicrobial Filter Bracket

    Installation Instructions (Model GXRV40TBN 00) FAUCET ELECTRONICS (on some models) FAUCET ELECTRONIC TIMER POWER UP THE FAUCET TIMER Inside the faucet handle is a battery operated 6 1. On the faucet handle, locate the battery cover. month timer. On a new Reverse Osmosis system,...
  • Page 20: Connect Tubes (Gxrv40Tbn 00)

    Installation Instructions (Model GXRV40TBN 00) HOW TO CONNECT TUBES The Reverse Osmosis system includes push-in 2. If additional tubing is required, see parts list at fittings for quick tubing connection. Review the the end of this manual. following instructions before connecting the tubes...
  • Page 21: Black Tube

    Installation Instructions (Model GXRV40TBN 00) MAKE TUBING CONNECTIONS (Cont.) RO Product Water Faucet 3/8” Blue Tubes 3/8” Black Drain Tube Adapter Water Supply Fitting 1/4” Green INLET HOT COLD Tube Sink Tank P–Trap Connector Remineralization/ Antimicrobial Filter 1/4” Red Tube OUTLET 3/8”...
  • Page 22: Storage Tank And Faucet (Gxrv40Tbn 01)

    Installation Instructions (Model GXRV40TBN 01) STORAGE TANK AND FAUCET STORAGE TANK INSTALLATION 1. Apply thread sealing tape (2 wraps clockwise) to the threads on the nipple at the top of the tank. Tank Faucet Nipple Tank Connector Wrap thread sealing tape on threads Base Full-Circle...
  • Page 23 Installation Instructions (Model GXRV40TBN 01) FAUCET (continued) INSTALL THE FAUCET (Cont.) 5. Work the tubing and the faucet stud down into the mounting hole. Be sure that the rubber 1. If drilling is needed, drill a 1-1/4" diameter hole gasket seats inside the recess in the faucet in the mounting surface.
  • Page 24: Connect Tubes (Gxrv40Tbn 01)

    Installation Instructions (Model GXRV40TBN 01) HOW TO CONNECT TUBES The Reverse Osmosis system includes push-in 2. If additional tubing is required, see parts list at fittings for quick tubing connection. Review the the end of this manual. following instructions before connecting the tubes Collet O-Ring in the next step.
  • Page 25 Installation Instructions (Model GXRV40TBN 01) MAKE TUBING CONNECTIONS (Cont.) RO Product Water Faucet 3/8” Blue Faucet Tubes Connector 3/8” Black Tube Drain Water Supply Adapter Fitting 1/4” Green INLET HOT COLD Tube Sink Tank P–Trap Connector Remineralization/ 1/4” Red Antimicrobial Tube Filter OUTLET...
  • Page 26: Sanitize The System

    4. Add 3 ml. of bleach into open end of yellow Osmosis system. tube. Handle bleach according to bleach manufacturer’s recommendations. To order, call toll-free GE Appliances Parts and 5. Connect yellow tube to tank connector. Services at 800.952.5039 (US). 6. Sanitizing the system will be completed during the pressure test and purging steps on the following page.
  • Page 27: Test And Purge The System

    Installation Instructions TEST AND PURGE THE SYSTEM PRESSURE TEST THE SYSTEM PURGE THE SYSTEM NOTE: Complete the sanitizing procedure on the To purge the system, complete the following steps. preceding page before pressure testing. 1. Open the Reverse Osmosis faucet and let water To pressure test the system, complete the flow through the system for a 24 hour period.
  • Page 28: Care And Cleaning

    See Reverse Osmosis cartridge replacement. system. See previous page for instructions. To obtain replacement filters, call toll-free GE Appliances Parts and Services at 800.952.5039 (US), or visit the store where you purchased your reverse osmosis system. Prefilter / Postfilter Cartridge Replacement FQ18PN...
  • Page 29 Care and Cleaning (Model GXRV40TBN 00) CARTRIDGE REPLACEMENT (Cont.) Manifold Prefilter Cartridge Cartridge Turn filter cartridges counterclockwise to remove from manifold Turn filter cartridges clockwise to attach to manifold Postfilter Cartridge CHANGE FAUCET BATTERY (on some models) WARNING Chemical Burn Hazard: Your faucet may contain an indicator light powered by a lithium button cell battery.
  • Page 30: Cartridge Life And Replacement (Gxrv40Tbn 01)

    See Reverse Osmosis cartridge replacement. system. See page 27 for instructions. To obtain replacement filters, call toll-free GE Appliances Parts and Services at 800.952.5039 (US), or visit the store where you purchased your reverse osmosis system. Prefilter / Postfilter Cartridge Replacement FQ18PN...
  • Page 31 Care and Cleaning (Model GXRV40TBN 01) CARTRIDGE REPLACEMENT (Cont.) Manifold Prefilter Cartridge Cartridge Turn filter cartridges counterclockwise to remove from manifold Turn filter cartridges clockwise to attach to manifold Postfilter Cartridge...
  • Page 32: Drain Flow Control

    Care and Cleaning THE WATER TEST KIT To obtain an independent laboratory water test kit, please call IAS Labs at 1.602.273.7248 and leave your contact details. They will contact you to find out what water tests you are interested in, and inform you of the cost of the testing.
  • Page 33: Troubleshooting Tips

    This reduce the pressure below 80 psi. may be associated with high pressure water supply, generally 80 psi or greater. If you are still having trouble, please visit www.GEAppliances.com/ge/service-and-support/contact.htm or call us at 800.952.5039 (US).
  • Page 34: Parts List (Gxrv40Tbn 00)

    Parts List GXRV40TBN 00...
  • Page 35: Parts Catalog

    Parts Catalog GXRV40TBN 00 REF. GE APPLIANCES PART NO. PART DESCRIPTION QUANTITY 0001 WS19X21938 CABINET ASSEMBLY, LEFT HALF, RIGHT HALF, AND DRIP TRAY 0002 FQ18PN PRE AND POST FILTER CARTRIDGE SET 0003 FQ18MN RO CARTRIDGE 0004 WS19X21937 MANIFOLD ASSEMBLY (INCLUDES REF. NO. 0001...
  • Page 36: Parts List (Gxrv40Tbn 01)

    Parts List GXRV40TBN 01...
  • Page 37 Parts Catalog GXRV40TBN 01 REF. GE APPLIANCES PART NO. PART DESCRIPTION QUANTITY 0001 WS19X21938 CABINET ASSEMBLY, LEFT HALF, RIGHT HALF, AND DRIP TRAY 0002 FQ18PN PRE AND POST FILTER CARTRIDGE SET 0003 FQ18MN RO CARTRIDGE 0004 WS19X21937 MANIFOLD ASSEMBLY (INCLUDES REF. NO. 0001...
  • Page 38: Warranty

    USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service.
  • Page 39 Notes...
  • Page 40: Consumer Support

    Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience.

This manual is also suitable for:

Gxrv40tbn 01Gxrv40tbn