Page 2
The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.
About This Manual 1. About This Manual This manual contains information on the software and hardware features of the Beijer Electronics GT-5102 High Speed Counter Module. It provides in-depth specifications, guidance on installation, setup, and usage of the product. 1.1. Symbols Used in This Manual This publication includes Warning, Caution, Note and Important icons where appropriate, to point out safety-related, or other important information.
Before using this product, please read this manual and other relevant manuals carefully. Pay full attention to safety instructions! In no event will Beijer Electronics be responsible or liable for damages resulting from the use of this product. The images, examples and diagrams in this manual are included for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Beijer Electronics cannot take responsibility or liability for actual use based on the examples and diagrams.
IP, EtherCAT, PROFINET, CC-Link IE Field, PROFIBUS, CANopen, DeviceNet, CC-Link, MODBUS/Serial etc. • Expansion Module - Expansion module types: Digital IO, Analog IO, and Special modules. • Messaging - The system uses two types of messaging: Service messaging and IO messaging. Beijer Electronics, Doc ID: 149962 2025-02...
Valid parameter data depends on the modules in use. For example, analog modules have settings of either 0-20 mA or 4-20 mA, and temperature modules have settings such as PT100, PT200, and PT500. The documentation for each module provides a description of the parameter data. 2025-02 Beijer Electronics, Doc ID: 149962...
Not used. Field power bypass to next expansion module Wiring IO cable max. 2.0 mm² (AWG 14) Torque 0.8 Nm (7 lb-in) Weight 60 g Module size 12 mm x 99 mm x 70 mm Beijer Electronics, Doc ID: 149962 2025-02...
Page 12
A- and B-, then connect A- and B- to the field power 0V. The reason for this is that A+ and B+ receive the signals output from the encoder, while A- and B- serve the role of establishing the reference voltage for the input signals, making their connection essential. 2025-02 Beijer Electronics, Doc ID: 149962...
LED color Aph input Ch#0 Green Bph input Ch#0 Green Aph input Ch#1 Green Bph input Ch#1 Green LED channel status Status LED is Indication No signal Normal operation On signal Green Normal operation Beijer Electronics, Doc ID: 149962 2025-02...
*** Pulse width, B’1110(0xE) measures Aph input’s high (on) pulse width (32 bit) in 0.1 us unit. **** Pulse width & period, B’1111(0xF) measures Aph’s pulse high (on) width (16 bit) & period (16 bit) in 0.1 us unit. 2025-02 Beijer Electronics, Doc ID: 149962...
Page 15
*** Pulse width, B’1110(0xE) measures Aph input’s high (on) pulse width (32 bit) in 0.1 us unit. **** Pulse width & period, B’1111(0xF) measures Aph’s pulse high (on) width (16 bit) & period (16 bit) in 0.1 us unit. Beijer Electronics, Doc ID: 149962 2025-02...
Page 16
*** Pulse width, B’1110(0xE) measures Aph input’s high (on) pulse width (32 bit) in 0.1 us unit. **** Pulse width & period, B’1111(0xF) measures Aph’s pulse high (on) width (16 bit) & period (16 bit) in 0.1 us unit. 2025-02 Beijer Electronics, Doc ID: 149962...
Parameter Data 8. Parameter Data Valid parameter length: 4 bytes Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved Reserved Reserved Reserved Beijer Electronics, Doc ID: 149962 2025-02...
Installation position is valid vertical and horizontal. The drawings are illustrative and may be out of proportion. CAUTION NOT following the space requirements may result in damaging the product. 2025-02 Beijer Electronics, Doc ID: 149962...
• GT-5XXX • GT-7XXX GN-9XXX modules have three locking levers, one at the bottom and two on the side. For mounting instructions, refer to Mount GN-9XXX Module. Mount to DIN rail Dismount from DIN rail Beijer Electronics, Doc ID: 149962 2025-02...
Page 20
9.2.2. Mount GN-9XXX Module To mount or dismount a network adapter or programmable IO module with the product name GN-9XXX, for example GN-9251 or GN-9371, see the following instructions: Mount to DIN rail Dismount from DIN rail 2025-02 Beijer Electronics, Doc ID: 149962...
Hardware Setup 9.3. Mount Removable Terminal Block To mount or dismount a removable terminal block (RTB), see the instructions below. Mount a removable terminal block Dismount a removable terminal block Beijer Electronics, Doc ID: 149962 2025-02...
To connect/disconnect cables to/from the removable terminal block (RTB), see the instructions below. WARNING Always use the recommended supply voltage and frequency to prevent damage to the equipment and ensure optimal performance. Connect cable Disconnect cable 2025-02 Beijer Electronics, Doc ID: 149962...