  • Page 1 USER GUIDE & SERVICE MANUAL Model: URNP115-IS01A...
  • Page 2 USER GUIDE & SERVICE MANUAL Click on any section below to jump directly there Table of Contents Intro Product Liability Parts Safety R600a Specifications Safety and Warning Compressor Specifications Disposal And Recycling Warranty Installation Environmental Requirements Electrical Cutout & Product Dimensions Water Hookup Drain General Installation...
  • Page 3: Product Information

    U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4: Safety And Warning

    USER GUIDE Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Disposal And Recycling

    USER GUIDE Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely:...
  • Page 6: Environmental Requirements

    USER GUIDE Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
  • Page 7 USER GUIDE Electrical WARNING SHOCK HAZARD - Electrical Groundining Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    Cutout & Product Dimensions 14 ⁄ ” (378 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit FRONT does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, 33 ⁄...
  • Page 9: Water Hookup

    USER GUIDE rupture with age and cause damage to your home. Water Hookup Do not use tape or joint compound when PREPARE PLUMBING attaching a braided flexible water supply line Plan the arrangement of the water supply pipes. that includes a rubber gasket. The gasket Connect a 1/4”...
  • Page 10: Drain Connection

    USER GUIDE Drain There is a possibility that hose connections may have loosened during shipment. Verify all connections and fittings are free from leaks. SECURE DRAIN HOSE TO BACK PANEL CAUTION CAUTION This equipment is to be installed with adequate Do not pull or bend the drain hose to avoid backflow protection to comply with applicable damage to drain pump.
  • Page 11: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
  • Page 12: Integrated Panel Dimensions

    USER GUIDE Integrated Panel Dimensions Integrated Panel Dimensions INTEGRATED PANEL BACK SURFACE MUST HAVE AMPLE FLAT SURFACE 3/4” TO MOUNT OVERLAY PANEL FLAT AND WITHOUT INTERFERENCE (19 mm) NOTICE 14 ⁄ ” Due to differences in surrounding cabinetry, the (379 mm) panel may not perfectly align with door.
  • Page 13: Integrated Panel Installation

    PREPARE INTEGRATED PANEL Stainless Steel panel is an accessory that is sold Remove door from unit separately. Please Visit U-Line.com for details. (See To Reverse the Door Swing) Remove gasket and gasket channel filler to expose On a flat surface, line up the door to the integrated side holes.
  • Page 14: Door Swing

    USER GUIDE Door Swing This unit is equipt with a door that opens past 90 . For this reason, it will be necessary to carefully plan where the unit is installed in relationship to walls and surrounding appliances. The ONP115 door opens to a maximum of 105 Wall Door Swing...
  • Page 15: Door Adjustments

    USER GUIDE Door Adjustments Prepare Door REVERSE DOOR SWING Rotate door 1800. The hinges are attached to the right-hand side of the door Remove gasket and gasket channel cover. when the product is shipped from the factory. However, the ice maker is designed so that the hinges may Install gasket and gasket channel cover on opposite be installed on either side.
  • Page 16: First Use

    USER GUIDE First Use INITIAL STARTUP Turn on the water supply to the ice maker. Connect ice maker to power source. Open door and locate the switch at the bottom area of the machine. Set the switch to The ice maker will be begin to produce ice. Discard the first 2 batches of ice.
  • Page 17: Display Panel

    USER GUIDE DISPLAY PANEL Light No Water Drain Button Lamp Lamp Lamp CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES Light Button Press and release Light turns on or off Ice Lamp Lights up when operation switch is set to “ICE” No Water Lamp Lights up to indicate low water supply Drain Lamp Lights up to indicate activation of the drain valve.
  • Page 18 USER GUIDE CAUTION ⁄ ” Do not put anything other than ice in the ice bin. Wine or beer bottles are unsanitary and a detached label may block the drain. CAUTION ⁄ ” If the ice storage bin is full of water, turn off the ⁄...
  • Page 19 USER GUIDE u-line.com Airflow NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
  • Page 20: Internal Cleaning

    Read and understand all labels printed on the package before use. Clean the Ice Bin U-Line Ice Machine Cleaner is used to remove lime scale and other mineral deposits. Refer to the following steps to The ice bin should also be cleaned regularly.
  • Page 21: Cleaning The Condenser

    USER GUIDE Cleaning the Condenser WARNING Disconnect electric power to the unit before cleaning the condenser. DO NOT use any type of cleaner on the condenser unit. Condenser may be cleaned using a vacuum, soft brush, or compressed air. The condenser should be cleaned 2-3 times a year to remove any lint that has penetrated the condenser.
  • Page 22: Troubleshooting

    USER GUIDE Troubleshooting LAMP CURRENT • • • CAUSES ACTION CONDITION DRAIN WATER When the operation switch is switched to Ice Making position. When you turn the operation switch to When the operation switch is the ‘off’ position, the water will drain Washing changed to , the ‘ICE’...
  • Page 23: Maintenance Schedule

    8. Maintenance Schedule USER GUIDE -The following maintenance schedule is guideline 8. Maintenance Schedule 8. Maintenance Schedule -Maintenance and repair should be done more frequently according to water quality, equipment usage environment and local hygiene regulations. -The following maintenance schedule is guideline -The following maintenance schedule is guideline 8.
  • Page 24: Wire Diagram

    USER GUIDE Wire Diagram Wire Diagram...
  • Page 25: Product Liability

    The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 26 USER GUIDE URNP115-IS01A • NUGGET ICE MACHINE 11 18 Parts...
  • Page 27 USER GUIDE URNP115-IS01A • NUGGET ICE MACHINE AIR SENSOR (BLUE) 80-55453-06 FRONT LOW-COVER KIT: PIN TYPE 80-55342-08 AUGER ASSEMBLY 80-55381-02 GASKET DOOR ASSY (SOLID) 80-55453-08 BACK PANEL (REAR COVER) 80-55342-09 GRILLE ASSEMBLY (OUTDOOR) 80-55342-07 BASE BRACKET(G-BOX) 80-55342-01 ICE MAKING UNIT (NUGGET)
  • Page 28 Never use a torch on a fully charged refrigeration system. R-600a is heavier than air, do not allow any Never substitute U-Line OEM replacement parts leakage/migration to low areas such as or methods of construction. basements and stairs. Never substitute U-Line OEM replacement parts or methods of construction.
  • Page 29 USER GUIDE R290/R600a SPECIFICATIONS/LABELING WARNING R290/R600a equipped products are labeled (both the unit Only skilled and well trained service technicians and the compressor). permitted to service R290/R600a equipped products. R290/R600a is colorless and odorless. All tools and equipment must be approved for R290/R600a is considered non-toxic, but is flammable use with R290/R600a refrigerant.
  • Page 30: Leak Detection

    USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with system is empty of R290/R600a before any system work is...
  • Page 31 USER GUIDE USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Proper ventilation during service is required. The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the Never apply a torch to a charged R290/R600a refrigeration compressor off (equalized pressure).
  • Page 32: Compressor Specifications

    USER GUIDE USER GUIDE Compressor Specifications HYS67MGU72a Refrigerant R600a DANGER Voltage 115 - 127 VAC Frequency 60 Hz Run Cap 8μF/450 VAC Electrocution can cause death or serious injury. Start Winding 8 Ohm at 77°F Burns from hot or cold surfaces can cause Run Winding 7.1 Ohm at 77°F serious injury.
  • Page 33: One Year Limited Warranty

    For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.