U-Line UHNP315 User Manual & Service Manual

U-Line UHNP315 User Manual & Service Manual

15” nugget ice machine

Advertisement

USER GUIDE & SERVICE MANUAL
3 Class
UHNB315 / UHNP315
15" Nugget Ice Machine

Advertisement

Table of Contents
loading

Summary of Contents for U-Line UHNP315

  • Page 1 USER GUIDE & SERVICE MANUAL 3 Class UHNB315 / UHNP315 15” Nugget Ice Machine ● ●...
  • Page 2: Table Of Contents

    USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Contents Intro Warranty Safety Safety and Warning Disposal And Recycling Installation Environmental Requirements Electrical Cutout & Product Dimensions Side by Side Installation Water Hookup Drain...
  • Page 3: U-Line.com

    1. U-Line Customer Care must be contacted immediately at +1.800.779.2547. 2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
  • Page 7: Electrical

    USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    14 ⁄ ” (379 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, 28”...
  • Page 9: Side By Side Installation

    USER GUIDE u-line.com Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16" (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be Side-by-Side Installation needed for any knobs, pulls or handles installed. Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s...
  • Page 10: Water Hookup

    The water valve uses a standard 1/4" (6.35 mm) is under pressure at all times. Plastic may crack compression fitting. U-Line recommends using accessory or rupture with age and cause damage to your water hook up kit – part # 80-54674-00. The kit includes a home.
  • Page 11 USER GUIDE u-line.com 1. Turn off water supply and disconnect electrical supply to 5. Turn on water supply and check for leaks. product prior to attempting installation. 6. Reinstall back panel. 2. Remove the back panel. 3. Thread water line through back panel hole (with bushing).
  • Page 12: Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1"...
  • Page 13 (Optional Hook-Up) spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Valve DRAIN PUMP section in the User Manual.
  • Page 14: Anti-Tip Bracket

    USER GUIDE u-line.com Anti-Tip Bracket Surrounding area (Top view) Use one of the methods below to secure the unit CABINET/COUNTER ANTI-TIP INSTALLATION (For built-in applications) Back of unit Back wall Slide unit out so screws on front of unit are easily accessible.
  • Page 15: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. LEVELING INFORMATION 1. Use a level to 2. Gently push the unit into position. Be careful not to confirm the unit is entangle the cord or water and drain lines, if level.
  • Page 16: Grille Installation

    USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
  • Page 17: Door Swing

    USER GUIDE u-line.com Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/2" (13 mm) 1/2" (13 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame.
  • Page 18: Door Adjust

    USER GUIDE u-line.com Door Adjustments REVERSING THE DOOR Open door. DOOR ALIGNMENT AND ADJUSTMENT Using T-25 Torx bit loosen screw #1 and remove screw Align and adjust the door if it is not level or not sealing #2 on top and bottom hinge. Slide and remove the properly.
  • Page 19: First Use

    Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 20: Control Operation

    USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn ON or OFF Adjust ice density See “Ice” section Option Open Door White While holding press and release Adjust light color...
  • Page 21: Ice

    The factory default ice setting is 0, which produces a firm and compact ice nugget. U-Line’s exclusive U-Choose™ ice adjustability feature allows you five levels of adjustment from 0 to -5. At -5 the ice is soft and chewable.
  • Page 22: Airflow And Product Loading

    USER GUIDE u-line.com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
  • Page 23: Cleaning

    USER GUIDE u-line.com Cleaning Using abrasive pads such as ScotchBrite™ will cause the graining in the stainless steel to EXTERIOR CLEANING become blurred. Vinyl Clad (Black or White) Models Clean surfaces with a mild detergent and warm water Rust not cleaned up promptly can penetrate the solution.
  • Page 24 Vent Tube and Funnel Clean water SafeCLEAN Plus™ Cleaner (Part No. 80-55266-00) – included with unit Dispenser Need more cleaner? Visit u-line.com. Tube CAUTION Press and release will appear in the display Use only SafeCLEAN Plus Cleaner. Use of any b.
  • Page 25 The filter must remain in place when using the machine. The filter, part # 80-55-268-00, should be replaced every 6 to 12 months. See your dealer or u-line.com for replacement filters. To remove filter, press and rotate counterclockwise approximately turn.
  • Page 26: Cleaning Condenser

    USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
  • Page 27: Extended Non-Use

    USER GUIDE u-line.com Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN For questions regarding winterization, please call U-Line at 800.779.2547. The following steps are recommended for periods of extended non-use: CAUTION 1. Remove all consumable content from the unit. Damage caused by freezing temperatures is not 2.
  • Page 28 One Year Limited Warranty For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.

This manual is also suitable for:

Uhnb315