1. General safety instructions 1.3. Operation safety ( Heating system ) Before first use read the manual carefully and follow the 1. The device is not intended for use by persons (including instructions contained therein. The manufacturer is not liable children) with limited physical, sensory or mental abilities, or by for damage caused by equipment used inappropriately or by inexperienced users, unless under supervision or with...
Installation of an electrical float switch 4.1. Setting up • Place the triangular piece with the probe in the 1. Ensure that the controller switched off before plugging right-hand corner, next to the controller the power cord in. • Align and mark the holes for drilling 2.
in °C. Preset temperature limit setting mode (L.t.h.) code L-4 – activated by holding down the "ON/OFF" button. The display shows the maximum value of the preset temperature that can be set. The L... indication is given in °C. button "-" decrease value 4 –...
Error Code Description 4.4. Controller specifications (E-0) CPU Internal controller fault STATUS Controller specifications (FOR FW: 0.1 T1 measured temperature too (E-3) T < Tmin version) T1 measured temperature too (E-4) T > Tmax high. Temperature C ... +250 pressed/faulty „-„ button measurement (E-5) Button - range...
7. Warranty The product purchased from the Lyson Company is covered by a manufacturer's warranty. The warranty period is 24 months from the date of purchase. All purchased products come with receipts or VAT invoices.
Need help?
Do you have a question about the W2081 and is the answer not in the manual?
Questions and answers