LYSON W2081 Instruction Manual

Settling tank with vertical sieve

Advertisement

Quick Links

Instructions Manual
Settling tank with vertical sieve
Przedsiębiorstwo Pszczelarskie Łysoń
Spółka z o.o.
34-124 Klecza Górna, st.Pszczela 2, Poland
www.lyson.eu, e-mail; lyson@lyson.com.pl
Tel. +48 33/875-99-40, +48 33/870-64-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W2081 and is the answer not in the manual?

Questions and answers

Summary of Contents for LYSON W2081

  • Page 1 Instructions Manual Settling tank with vertical sieve Przedsiębiorstwo Pszczelarskie Łysoń Spółka z o.o. 34-124 Klecza Górna, st.Pszczela 2, Poland www.lyson.eu, e-mail; lyson@lyson.com.pl Tel. +48 33/875-99-40, +48 33/870-64-02...
  • Page 2: Table Of Contents

    This manual covers following devices (codes): W2081, W2081A, W2082A, W2084 Table of contents 1. General safety rules 1.1. Intended use 1.2. Electrical safety 1.3. Operation safety 2. Vertical sieve operation 2.1. Work principles 3. Additional features 4. MHC-01 temperature controller 4.1.
  • Page 3: General Safety Instructions

    1. General safety instructions 1.3. Operation safety ( Heating system ) Before first use read the manual carefully and follow the 1. The device is not intended for use by persons (including instructions contained therein. The manufacturer is not liable children) with limited physical, sensory or mental abilities, or by for damage caused by equipment used inappropriately or by inexperienced users, unless under supervision or with...
  • Page 4: Work Principles

    3. Additional features: Technical specifications – heated version • mechanical floating switch length 1500 mm length 1000 mm - power 440 W - power 520 W - stainless steel 0H18N9 - stainless steel 0H18N9 - ball valve 6/4 - ball valve 6/4 - H/W/L -350/510/1100 - H/W/L -350/510/1600 - power supply 230V...
  • Page 5: Mhc-01 Temperature Controller

    Installation of an electrical float switch 4.1. Setting up • Place the triangular piece with the probe in the 1. Ensure that the controller switched off before plugging right-hand corner, next to the controller the power cord in. • Align and mark the holes for drilling 2.
  • Page 6: Error Codes

    in °C. Preset temperature limit setting mode (L.t.h.) code L-4 – activated by holding down the "ON/OFF" button. The display shows the maximum value of the preset temperature that can be set. The L... indication is given in °C. button "-" decrease value 4 –...
  • Page 7: Controller Specifications

    Error Code Description 4.4. Controller specifications (E-0) CPU Internal controller fault STATUS Controller specifications (FOR FW: 0.1 T1 measured temperature too (E-3) T < Tmin version) T1 measured temperature too (E-4) T > Tmax high. Temperature C ... +250 pressed/faulty „-„ button measurement (E-5) Button - range...
  • Page 8: Cleaning And Maintenance

    7. Warranty The product purchased from the Lyson Company is covered by a manufacturer's warranty. The warranty period is 24 months from the date of purchase. All purchased products come with receipts or VAT invoices.

This manual is also suitable for:

W2081aW2082aW2084

Table of Contents