Alphanumeric call (using contact alias in the address book) Lift Control Function Fire-fighting OnVif IP cameras Dimensional data and installation heights Front and rear view item 373005/06/07 Installation item 373005/06/07 Uninstall item 373005/06/07/08 Front and rear view item 373008 Installation item 373008...
Page 4
7” touch display standard indoor unit User and installation manual Home page Lift Alarm Activity Video door entry functions Receive a call from EP Receive a call from IU or GS Call IU or GS List of personal contacts Call IU or GS using the contact list Call history Blacklist Messages...
7” touch display standard indoor unit User and installation manual General information Warnings and recommendations It is important to read this manual carefully before proceeding with the installation. The warranty becomes automatically void in case of negligence, improper use, tampering by unauthorised personnel.
7” touch display standard indoor unit User and installation manual Fundamental concepts The device cannot be activated individually but must follow a general configuration found on the DES Server. The DES Server is configured using a PC connected to the same LAN. Once configured and activated, the DES Server makes available the configuration of local devices (Internal Unit, Entrance Panel, Guard Station, etc.) When switched on, the device searches for a configuration (address book) on the DES Server and...
7” touch display standard indoor unit User and installation manual Call addressing procedures On the basis of data recorded in the AB and the Community structure the calls can be made using various methods: – numeric call (using the standard address of the community);...
7” touch display standard indoor unit User and installation manual Alphanumeric call (using Alias) The Alias is an alphanumeric code that replaces the community address created through the software. The default alias is the same as the address in the Community*. However, this can be changed using the SW and can be of two types: alias ALPHANUMERIC 1 1 01 04 02...
The Lift Control function consists of the ability to interact with the lift system through calls and commands from the DES IP video door entry system. The operating mode of the lift depends on its control system (BTicino cannot operate the lift but only send commands, which are interpreted and executed).
7” touch display standard indoor unit User and installation manual Dimensional data and installation heights * Recommended height, unless different regulations are specified. 189 mm 27 mm 8 mm 142,5 mm 49 mm 60 mm 83,5 mm 120 mm...
7” touch display standard indoor unit User and installation manual Front and rear view item 373005/06/07 1. Display 7" (touch screen) 2. Microphone 12 V RJ45 3. Loudspeaker 4. Clamp for additional SOS call 5. Clamp for doorbell call 6. RJ45 Connector ( * ) 7.
Page 13
7” touch display standard indoor unit User and installation manual SOS- DoorBell- 12 V DC24V RJ45 Alarm connection clamp F1 – GND Infrared F2 – GND Magnetic contact F3 – GND Smoke sensor F4 –GND Gas sensor F5 – GND Water sensor F6 –...
7” touch display standard indoor unit User and installation manual Installation item 373005/06/07 Attention: The wrong wiring of the Ethernet cable connecting the device to the Poe Switch 375002 could damage the device itself.. The RJ45 cable must be at least 200 mm long.
7” touch display standard indoor unit User and installation manual Front and rear view item 373008 1. Display 7" (touch screen) 2. Microphone 12 V RJ45 3. Loudspeaker 4. Clamp for additional SOS call 5. Clamp for doorbell call 6. Connector RJ4510/100 Base T - IEEE 802.3at (POE+) (*) 7.
Page 16
7” touch display standard indoor unit User and installation manual SOS- DoorBell- 12 V RJ45 Alarm connection clamp F1 – GND Infrared F2 – GND Magnetic contact F3 – GND Smoke sensor F4 –GND Gas sensor F5 – GND Water sensor F6 –...
7” touch display standard indoor unit User and installation manual Installation item 373008 Attention: The wrong wiring of the Ethernet cable connecting the device to the Poe Switch 375002 could damage the device itself.. The RJ45 cable must be at least 200 mm long. Uninstall item 373008...
7” touch display standard indoor unit User and installation manual Activation After configuring the MAC address of the device in the SD, when switched on, the device searches for a configuration (address book) on the DES Server and acquires it. NOTE: if the device were already configured in the past, it must be reset.
7” touch display standard indoor unit User and installation manual IP address Server IP address DEFAULT CONFIGURATION Installation code Installation code Server IP address DEFAULT CONFIGURATION 1A. Enter the IP address of the server. 1B. Enter the installation code...
7” touch display standard indoor unit User and installation manual Example diagrams A - Diagram with power supply by BTicino PoE Switch CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables 2 x Copper cables It is possible to use two different types of connection according to installation situation:...
Page 21
User and installation manual B - Diagram with local power supply CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables 2 x Copper cables It is possible to use two different types of connection according to installation situation:...
7” touch display standard indoor unit User and installation manual Ethernet connection CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables 2 x Copper cables FLOOR 3 APARTMENT 5 APARTMENT APARTMENT APARTMENT 374004 RJ45 373001 RJ45 373001...
7” touch display standard indoor unit User and installation manual Ethernet connection to the Standard PoE switch CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables FLOOR 3 373008 373008 373008 373008 APARTMENT...
7” touch display standard indoor unit User and installation manual Fiber optic riser connection (case of higher bandwidth demand) LAN PoE Standard LAN PoE BTicino LAN Ethernet Optical fiber Copper cables n° 2 Copper cables CABLES LEGEND FLOOR 3 APARTMENT 5...
User and installation manual Intercom function Audio intercom between internal unit: - of different apartments (same building or different building) - inside the same apartment. CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables 373008 373008 373008 APARTMENT 1...
7” touch display standard indoor unit User and installation manual Lift control 1 - Lift control with protocol interface 375010, 1 riser, 1 entrance panel CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables 373008...
7” touch display standard indoor unit User and installation manual Lift control 2 - Lift control with protocol interface 375010, more risers, 1 entrance panel CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables MONTANTE 1...
7” touch display standard indoor unit User and installation manual Lift control 3 - Lift control with protocol interface 375010, 1 riser, more entrance panels CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables FLOOR 3...
7” touch display standard indoor unit User and installation manual Lift control 1 - Lift control with lift control interface with relay 375013, 1 riser, 1 entrance panel CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables 373008...
User and installation manual Lift control 2 - Lift control with lift control interface with relay 375013, more risers, 1 entrance panel CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables MONTANTE 1...
User and installation manual Lift control 3 - Lift control with lift control interface with relay 375013, 1 riser, more entrance panels CABLES LEGEND LAN PoE Standard LAN PoE BTicino LAN Ethernet Copper cables n° 2 Copper cables FLOOR 3...
7” touch display standard indoor unit User and installation manual Available functions item 373005/06/07 CABLES LEGEND LAN PoE BTicino LAN Ethernet Copper cables 2 x Copper cables Magnetic contact Magnetic contact Door bell pushbutton Water Smoke Magnetic contact Infrared SOS Infrared...
7” touch display standard indoor unit User and installation manual Available functions item 373008 CABLES LEGEND LAN PoE BTicino LAN Ethernet Copper cables 2 x Copper cables Magnetic contact Magnetic contact Door bell pushbutton Water Smoke Magnetic contact Infrared SOS Infrared...
7” touch display standard indoor unit User and installation manual Functions using the device After installing the IP DES Indoor Unit it is possible to: – Call the lift; – Receive a call from Receive a call from IU or –...
7” touch display standard indoor unit User and installation manual Introduction After the installation and connection of the device, it is necessary to configure it and create the Community structure. For details see Server DES Software manual. Step Community VLAN network creation Step Community structure definition Step...
7” touch display standard indoor unit User and installation manual Home page This page may show different content according to the configuration and systems connected to the device. The Home Page, with all the functions enabled, is shown below. 15:16 Lift Silent Sept 02 Fri...
7” touch display standard indoor unit User and installation manual Lift This function calls the lift. Lift This function is active only if there is a Lift control interface item 375010/item 375013 in the community. For more information on the use with interface 375010 see "Lift control interface software manual". For more information on the use with interface 375013 see "IP DES SYSTEM software manual".
7” touch display standard indoor unit User and installation manual Alarm In this section, it is possible to activate at the same time all the sensors of the alarm system Alarm Alarm paragraph). connected to clamps F1 to F8 (see the 15:16 Lift Silent...
Page 39
7” touch display standard indoor unit User and installation manual 15:16 Disarm Lift Silent Sept 02 Fri Alarm password Activity Alarm Cancel Call Message Camera Alarm Settings 3. Enter the alarm code (ask the plant manager for your alarm code, available in the device parameters section of the SW) Caution: Save the codes in a safe place that is always accessible.
7” touch display standard indoor unit User and installation manual Activity Alarm paragraph). This function allows to activate the Activity check sensor (see the Activity 15:16 Lift Silent Sept 02 Fri Activity Alarm Call Message Camera Alarm Settings 1. Touch to activate the function 15:16 Lift Silent...
Page 41
7” touch display standard indoor unit User and installation manual 15:16 Disarm Lift Silent Sept 02 Fri Alarm password Activity Alarm Cancel Call Message Camera Alarm Settings 3. Enter the alarm code (ask the plant manager for your alarm code, available in the device parameters section of the SW) Caution: Save the codes in a safe place that is always accessible.
7” touch display standard indoor unit User and installation manual Video door entry functions Receive a call from EP When a call comes in, the display of the EP is activated, showing the image taken. Calling time 00:04 Calling from 1 Build.3#Entrance Panel full 10 inch... A It answers the call It rejects the call or ends the communication C Opens the door lock (if configured, it also controls the lift call)
Page 43
7” touch display standard indoor unit User and installation manual A confirmation message appears Door open Talk time 00:08 Talking with 1 Build.3#Entrance Panel full 10 inch... Note: it is possible to open the door lock even without answering the call 3.
7” touch display standard indoor unit User and installation manual Receive a call from IU or GS When a call comes in, the display of the EP is activated, showing the image taken. Calling time 00:04 Calling from 1 Area 1 Building 0 Floor 1 Apitem.. A Answers the call It rejects the call or ends the communication C Calling time...
7” touch display standard indoor unit User and installation manual Call IU or GS This section can be used to communicate with other IU installed in your home, or in other apartments. Call It is also possible to call the GS. It is possible to call an IU or GS in different ways: –...
Page 46
7” touch display standard indoor unit User and installation manual 1Area1Building01Riser01Floor01Apartment Calling time 00:06 Calling to 1Area1Building01Riser01Floor01Apartment 5. Wait for the person being called (A*) to answer or touch to end the call When the person being called answers, a picture taken by the IU appears (if this is a video call) *Note: the caller display depends on how the community has been configured using the software.
Page 47
7” touch display standard indoor unit User and installation manual Call Lift success Talk time 00:08 Talking with 1Area1Building01Riser01Floor01Apartment 8. Touch to end...
7” touch display standard indoor unit User and installation manual List of personal contacts In this section it is possible to add your Community contacts and, if necessary, add them in the favourites. Favorite Contacts Back 1 Build. - 1 Riser0 2#Guard station Call Apt.
Page 49
7” touch display standard indoor unit User and installation manual Modify/delete contact Favorite Contacts Back 1 Build. - 1 Riser0 2#Guard station Call Apt. 1 Build. - 1 Riser02#Guard station Contact (IU 2)1 Area 1Building 1 Riser 1 Floor 2... Call history BlackList 1.
Page 50
7” touch display standard indoor unit User and installation manual Favorite Contacts Back 1 Build. - 1 Riser0 2#Guard station Call Apt. 1 Build. - 1 Riser02#Guard station Contact (IU 2)1 Area 1Building 1 Riser 1 Floor 2... Call history BlackList 4.
7” touch display standard indoor unit User and installation manual Call IU or GS using the contact list After creating the contacts in the contact list, it is possible to call them directly. Call Note: the GS are automatically added to the list of personal contacts Back Call Apt.
7” touch display standard indoor unit User and installation manual Call history In this section it is possible to display the list of received, sent or missed calls, in chronological order. It is also possible to display the call details Back 1 Build.
7” touch display standard indoor unit User and installation manual Blacklist This section can be used to move the desired IU to the blacklist. With the blacklist function, any included IU trying to call will hear an engaged tone until removed again from the blacklist.
Page 55
7” touch display standard indoor unit User and installation manual Block all the intercom Back (USER)1 Area 2 Building 01 Riser 05 Floor 01 Apartment Call Apt. Contact Add successfully! Call history BlackList The IU has been added correctly to the blacklist, any call attempts will be met with an engaged tone Block all the intercom Back...
7” touch display standard indoor unit User and installation manual Messages In this section it is possible to display the messages received. Message The messages can contain text, images or videos. Depending on the function, they will be displayed in different sections: Origin Section Facility Manager from SW...
7” touch display standard indoor unit User and installation manual Voice mail This section can be used to view the messages left on your answering machine if the answering machine function has been activated in the Preference/Functions section Back 1 Area02#Entrance pan.. 02-09-2022 15:18:18 Voice mail Community...
7” touch display standard indoor unit User and installation manual Community In this section it is possible to display the community messages, coming from the Facility manager. Back New keys 02-09-2022 15:18:18 Voice mail Community Message 01 02-09-2022 15:14:47 Access history Family Emergency...
7” touch display standard indoor unit User and installation manual Family In this section it is possible to listen to the messages left by other members of the house or record one yourself. Add message Back 00:06 02-09-2022 15:18:18 Voice mail Community 00:03 02-09-2022 15:14:47...
Page 60
7” touch display standard indoor unit User and installation manual Back Voice mail Community 00:09 Access history Family Cancel Save Emergency 3. Touch to end 4. Touch to save the message A confirmation message appears Add message Back 00:09 03-09-2022 19:16:02 Voice mail Community 00:06...
7” touch display standard indoor unit User and installation manual Emergency In this section it is possible to display the emergency messages, coming from the Facility manager Back Fire Alarm 02-09-2022 15:18:18 Voice mail Community Access history Family Emergency A Delete the message 1.
7” touch display standard indoor unit User and installation manual Camera Camera In this section it is possible to directly access the EP you are authorized for (to which you have access to enter the Community) and display the OnVif IP cameras (that you are authorized for) Back Entrance Panel...
Page 63
7” touch display standard indoor unit User and installation manual Back Entrance Panel 1#Camera Common area 3. Touch to display the cameras on the system Note: this display must be enabled in the Function setting section 4. Touch to display a camera Monitoring time 00:06 Monitoring 1#Camera 5.
7” touch display standard indoor unit User and installation manual Alarm In this section it is possible to manage the alarm system sensors connected to the F1-F8 clamps. Alarm In particular it is possible to activate/deactivate the sensors and manage the alarm status. It is also possible to display the list of alarms detected by the sensors.
Page 65
7” touch display standard indoor unit User and installation manual Sensor status living room living room Sensore abilitato Disabled sensor Enabled sensor Infrared Infrared Instantaneous Instantaneous living room living room Active sensor Sensor in alarm Infrared Infrared Instantaneous Instantaneous living room beedroom living room kitchen...
Page 66
7” touch display standard indoor unit User and installation manual A pop-up appears following an alarm, the IU emits an audible warning and the signal LED on the device flashes 15:16 Lift Silent Sept 02 Fri Indoor Unit:01 Device n°1 Note: Infrared alarm, please check Activity...
Page 67
7” touch display standard indoor unit User and installation manual living room beedroom living room kitchen Back Alarm Zones Infrared defense area cancel the alarm Infrared Door Contact Smoke Instantaneous Delay 24 hours Instantaneous Alarm history · · · · · · · · ✔...
Page 68
7” touch display standard indoor unit User and installation manual Back Infrared 02-09-2022 15:18:18 Alarm Zones Alarm history Infrared 02-09-2022 15:14:47 Infrared 02-09-2022 15:13:39 SOS alarm 02-09-2022 15:07:05 Smoke alarm 02-09-2022 15:06:35 A Alarm to be displayed Type of probe C Date and time of the alarm D See details Delete the alarm...
7” touch display standard indoor unit User and installation manual Functions with Home+Security App After following the steps below, you will be able to interact with your device using the free Home+Security App. Make sure your installer has set up your system to allow you to interact with it using the Home+Security app Download the Home+Security App from the Stores Complete the...
7” touch display standard indoor unit User and installation manual Associate your 7” touch display standard indoor unit To be able to use the Home + Security App and thus use the functions of your device, it is necessary to: –...
Page 71
7” touch display standard indoor unit User and installation manual 5. Touch to enable the smartphone camera needed to scan the QR Code 6. Touch to continue. 15:16 Lift Silent Sept 02 Fri Activity Alarm Call Message Camera Alarm Settings 7.
Page 72
7” touch display standard indoor unit User and installation manual Back Back Scan this code from Home + Security app to continue configuration Scan this code from Home + Security app to continue configuration 9. Scan the QR code to connect the Home+Security app to the 7” touch display standard indoor unit Configuration Configuration...
Page 73
7” touch display standard indoor unit User and installation manual After being authenticated, from this page you can interact with your device and with the video door entry system. It is also possible to access various settings via the pull-down menu. The following screen appears on the 7”...
7” touch display standard indoor unit User and installation manual User settings Settings In this section it is possible to perform a wide range of customisations that will enable you to make the most of your IU. There are further configurations in the Installation section (installer access), accessed by means of the installer password.
7” touch display standard indoor unit User and installation manual Access code In this section it is possible to set different types of code Personal access code Set the code which opens the last EP of my community, i.e. the EP closest to the apartment, chosen from those to which I have access (default 4321*).
7” touch display standard indoor unit User and installation manual Ringtone In this section it is possible to set the IU ringtone volume 1. Scroll to modify the volume Preference In this section it is possible to modify some display parameters, enable the device camera and the key sound.
7” touch display standard indoor unit User and installation manual Function setting Display Function Back The key Sound Voice Mail Cancel Save 1. Touch to enable the sound when touching the virtual keypad keys 2. Touch to enable the answering machine 3.
7” touch display standard indoor unit User and installation manual Shortcut In this section it is possible to define which functions to display in the Home Page and to set up some parameters Home Page Shortcut Back Lift Control Silent mode Activity Alarm A Function in the home page...
7” touch display standard indoor unit User and installation manual Silent mode (scheduled silencing) settings Home Page Shortcut Back Silent mode Lift Control Silent mode Activity Alarm date 2022/02/01 – 2022/02/01 time 08:30 – 18:30 Cancel Save 1. Touch to select the start and end date to set the ringtone silencing period 2.
7” touch display standard indoor unit User and installation manual This section can be used to manage the association of the DES Internal Unit IP with the Home+Security app. Back Scan this code from Home + Security app to continue configuration Associate your 7”...
7” touch display standard indoor unit User and installation manual Advanced settings (Installation) This section can be used to set various parameters, such as enabling the display of functions, performing network tests, setting the installer password, performing resets and more. Back Access code Ringtone...
Page 83
7” touch display standard indoor unit User and installation manual Back Configuration Function Network Test Installation access code Alarm setting Restore factory View code 4. Touch the icon for the desired customisation, choosing among: Display the system address Configuration It enables the display of some functions on the home page and in other menus Function...
7” touch display standard indoor unit User and installation manual Function setting In this section it is possible to enable the display of some functions on the home page and in other menus. 1. Touch to enable the function display as shown in the following table: Message section Message It enables the display of the...
Page 85
7” touch display standard indoor unit User and installation manual Camera section It enables the display of the Common area function Alarm section It enables the display of the Alarm history function Call section Call It enables the display of the It enables the display of the apt.
7” touch display standard indoor unit User and installation manual Network test In this section it is possible to make a test call and test the data network Call test This function performs call tests between devices configured in the AB. Call test Call test Network Test...
7” touch display standard indoor unit User and installation manual Network test This function performs call tests of devices whose IP address is known 1. Enter the IP address of the device to test the connection 2. Touch to start the test Connection Success! If the test is successful, a confirmation message appears...
7” touch display standard indoor unit User and installation manual Install Password In this section it is possible to modify the installer password (the password can be viewed in the device parameters section of the SW*) Caution: Save the passwords in a safe place that is always accessible. (Cloud backup activation recommended).
7” touch display standard indoor unit User and installation manual Alarm setting In this section it is possible to display and set the Alarm system probes, connected to the device. A Sensor type Sensor enable (enable/disable) C Normally open (enable/disable) D Activation mode Device number (it corresponds to the contact from F1 to F8 to which the probe is connected) Set the sensor parameters...
7” touch display standard indoor unit User and installation manual Sensor parameters 1. Select the type of sensor based on the device connected among: – – Smoke – – Infrared – Door contact – Other 2. Enter the zone name 3.
7” touch display standard indoor unit User and installation manual Advanced parameters 1. Touch to modify the advanced settings Back Start of Day Time 06:00 Start of Night time 17:00 If no activity is detected within the defined time (hours) an alarm sounds Day Time Night time Zone...
7” touch display standard indoor unit User and installation manual Restore factory In this section it is possible to restore the factory values of the device Back Configuration Function Network Test Installation access code Alarm setting Restore factory View code 1.
7” touch display standard indoor unit User and installation manual View code In this section it is possible to display the passwords or the system access codes A It displays the code which opens the last EP of my community, i.e. the EP closest to the apartment, from those to which I have access (default 4321*).
7” touch display standard indoor unit User and installation manual Firmware update If a firmware update is available, the system sends an alert message 15:16 Lift Silent Sept 02 Fri New software version ready for update Activity Alarm Remind laterl Call Message Camera...
Page 95
7” touch display standard indoor unit User and installation manual...
Page 96
BTicino SpA Viale Borri, 231 21100 Varese www.bticino.com BTicino Spa reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality, the changes brought to the same.
Need help?
Do you have a question about the 373005 and is the answer not in the manual?
Questions and answers