SEELEY INTERNATIONAL BRAEMAR SDHV07D1S Installation Manual

Ducted inverter air conditioner

Advertisement

Quick Links

INSTALLATION MANUAL
DUCTED INVERTER AIR CONDITIONER
(English) (SDHV)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRAEMAR SDHV07D1S and is the answer not in the manual?

Questions and answers

Summary of Contents for SEELEY INTERNATIONAL BRAEMAR SDHV07D1S

  • Page 1 INSTALLATION MANUAL DUCTED INVERTER AIR CONDITIONER (English) (SDHV)
  • Page 2 SDHVD1S Series Ducted Inverter Unit...
  • Page 3: Table Of Contents

    Further, it could expose the Installer and/or the Retailer to serious liability. warranty. Further, it could expose the Installer and/or the Retailer to serious liability. SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 4: Before You Start

    BEFORE YOU START BEFORE YOU START Installation training is available from Seeley International Installation training is available from Seeley International INSTALLER AND MAINTENANCE CONTRACTORS INSTALLER AND MAINTENANCE CONTRACTORS for qualified and licensed installers; please contact your for qualified and licensed installers; please contact your...
  • Page 5: Most Common Causes Of Poor Cooling Performance

    Commissioning Commissioning Complete the commissioning sheet and checklist. Complete the commissioning sheet and checklist. 25-26 25-26 SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 6: Troubleshooting

    TROUBLESHOOTING PROBABLE CAUSE PROBLEM REMEDY 1.1 Power failure. 1. The air conditioner 1.1 Wait for power to resume. 1.2 Fuse blown or circuit breaker open. does not run. 1.2 Replace the fuse or reset the breaker. 1.3 Voltage is too low. 1.3 Find the cause and fix it.
  • Page 7: Typical Installation / Diagram Of Key Components

    4. Liquid Pipe 5. Gas Pipe 6. Drain Pipe Air outlet Indoor and Outdoor unit operating temperature range: Mode Indoor Unit Outdoor Unit Cooling 16°C to 30°C -15°C to 48°C Heating 16°C to 30°C -15°C to 24°C SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 8 COMPONENTS COMPONENTS The standard accessory parts listed below are supplied and should be used as required. The standard accessory parts listed below are supplied and should be used as required. Indoor Unit Accessories Indoor Unit Accessories Name Name Appearance Appearance Q'ty Q'ty Usage...
  • Page 9: Dimension (Mm)

    1011 1115 1220 DIMENSION (mm) SDHV10D1S SDHV12D1S 1117 1150 1340 MODEL SDHV14D1S SDHV07D1S 1011 1115 1220 SDHV16D1S 1353 1150 1497 SDHV10D1S SDHV12D1S 1117 1150 1340 SDHV14D1S SDHV16D1S 1353 1150 1497 SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 10: Indoor Unit Installation

    INDOOR UNIT INSTALLATION INDOOR UNIT INSTALLATION cont. MAKE SURE THE INDOOR UNIT IS INSTALLED WITH AIRFLOW IN THE DIRECTION AS SHOWN ON THE CONDENSATE DRAIN HOSE INSTALLATION cont. DECAL ON THE UNIT. 12. Considerations for units with a condensate pump: Seeley recommends the use of a safe tray under the indoor unit, complete with a separate drain.
  • Page 11 Return Duct – the duct that connects the return air grille to the appliance. Final Duct – the duct that connects directly to an outlet or diffuser. Fig 9 Fig 10 Fig 8 SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 12: Drain Options

    Drain Options: Option 1: Pump drain only Option 2: Pump drain only Option 1: Pump drain into gravity drain Option 2: Pump drain into gravity drain Option 1: Pump drain as overflow indicator Gravity drain to waste Option 2: Pump drain as overflow indicator Gravity drain to waste NOTE: Always connect the pump drain outlet...
  • Page 13: Outdoor Unit Installation

    OUTDOOR UNIT INSTALLATION. Fig. 15 RECOMMENDED CLEARANCES (mm) OUTDOOR MODEL SCHV07D1S > 100 > 100 > 350 > 700 > 100 SCHV10D1S SCHV12D1S > 300 > 1200 SCHV14D1S > 100 > 350 > 300 (150*) (600*) SCHV16D1S SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 14: Condensate Drainage

    OUTDOOR UNIT INSTALLATION cont. OUTDOOR DIMENSIONS OUTDOOR MODEL SCHV07D1S SCHV10D1S 1107 1100 SCHV12D1S SCHV14D1S 1085 1365 SCHV16D1S Fig.16 Location considerations should: Most importantly, do not install the Outdoor unit where there is a possibility it will cause a noise complaint from neighbours.
  • Page 15 The field installed pipe work and indoor coil MUST be connected to a vacuum pump and evacuated down to a vacuum pressure of 100 vacuum pressure of 100 µPa µPa minimum. minimum. SDHVD1S Series Ducted Inverter Unit SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 16: Refrigerant Pipe-Work

    NOTE: condensate is to be drained off to a catchment point in NOTE: condensate is to be drained off to a catchment point in Trap Trap accordance with local regulations. accordance with local regulations. Fig. 19 Fig. 19 SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 17: Electrical Wiring

    2. Power cord 3×1.0mm 2. Power cord 3×1.0mm (H05RN-F) (H05RN-F) 3. Communication Cords 2×0.75mm 3. Communication Cords 2×0.75mm (H05RN-F) (H05RN-F) SCHV14D1S / SDHV14D1S, SCHV14D1S / SDHV14D1S, SCHV16D1S / SDHV16D1S, SCHV16D1S / SDHV16D1S, SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 18 START UP & COMMISSIONING START UP & COMMISSIONING Ensure the electrical wiring has been completed, connected and switched on at Isolator. Check for correct voltage Ensure the electrical wiring has been completed, connected and switched on at Isolator. Check for correct voltage and number of phases.
  • Page 19 RH plate, but ensure they do not run parallel to the power lines to avoid improper operation. Ground both the indoor and outdoor units by attaching a ground wire. Unit shall be grounded in compliance with the applicable local and national codes. SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 20: Installing Wired Wall Controller

    INSTALLING WIRED WALL CONTROLLER STANDARD PARTS Description Quantity Base Box Baseplate Screw M4×25 Front Panel Installation Location and Installation Requirements Find a central location free of draughts, external walls and other heat sources (which may affect the temperature readings). Don’t install the wired controller in a damp place or under direct sunlight. Don’t install the wired controller close to high temperature objects or place where the wired controller is likely to suffer water spray.
  • Page 21 Wire both wall Controllers into Terminals H1 and H2 Located inside the indoor unit Step 2 Address the slave controller through the parameter settings How to Set a Slave Controller Note: XK60 Controller comes standard with unit XK75 Controller is an optional extra SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 22: Determination Of Correct Refrigerant Charge

    Refer overleaf for details on how to enter service mode and the functions / parameters available for programming the Refer overleaf for details on how to enter service mode and the functions / parameters available for programming the unit with. unit with. SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 23 On when ambient is below 35°C On when ambient is below 35°C Compressor sump heater Compressor sump heater On when ambient is below -2°C On when ambient is below -2°C SDHVD1S Series Ducted Inverter Unit SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 24 5 faults to view last 5 faults History History ▼ “Function” & “Function” & for 5 sec for 5 sec Note: Pressing “Enter/Cancel” button will save changes. Note: Pressing “Enter/Cancel” button will save changes. SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 25: Error Codes

    Drive desynchronizing protection Drive desynchronizing protection DRED3 Pfc protection Pfc protection ODU jumper malfunction ODU jumper malfunction Humidity sensor error Humidity sensor error Compressor start up failure Compressor start up failure SDHVD1S Series Ducted Inverter Unit SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 26: Braemar Refrigerated Air Conditioning - Commissioning Sheet

    Outdoor unit position in relation to indoor coil in metres – Above Below Below or Level or Level Condensate drain tested for leaks and water flow – yes Condensate drain tested for leaks and water flow – yes Full load amps Full load amps SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 27: Commissioning Checklist

    ......... SDHVD1S Series Ducted Inverter Unit SEELEY INTERNATIONAL - INSTALLATION MANUAL...
  • Page 28: Technical Specification

    1365 91 / 100 91 / 100 101 / 111 101 / 111 117 / 128 117 / 128 121 / 133 121 / 133 Weight Weight 69 / 74 69 / 74 (Nett/Gross) (Nett/Gross) SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 29 Warranty conditions are subject to property access and industry Safety Standards. Warranty conditions are subject to property access and industry Safety Standards. Seeley International strives for continuous product improvements, therefore specifications are subject to change Seeley International strives for continuous product improvements, therefore specifications are subject to change without notice.
  • Page 30: Notes

    NOTES NOTES SEELEY INTERNATIONAL – INSTALLATION MANUAL SEELEY INTERNATIONAL – INSTALLATION MANUAL...
  • Page 32: Warranty Service

    It is the policy of Seeley International to introduce continuous product improvement. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Seeley International Technical Support 1300 650 399...