  • Page 1 User Manual GL-9087 Network Adapter Module PROFINET network adapter, light version, max. 10 slices Doc ID: 175229 2025-02-20...
  • Page 2 The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    11.1. Mapping Data into Image Table .............. 27 11.2. Example of Input Process Image (Input Register) Map ........30 11.3. Example of Output Process Image (Output Register) Map ....... 31 12. Parameters ....................33 12.1. PROFINET IO Characteristics ..............33 Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 5: About This Manual

    About This Manual 1. About This Manual This manual contains information on the software and hardware features of the Beijer Electronics GL-9087 Network Adapter Module. It provides in-depth specifications, guidance on installation, setup, and usage of the product. 1.1. Symbols Used in This Manual This publication includes Warning, Caution, Note and Important icons where appropriate, to point out safety-related, or other important information.
  • Page 6: Safety

    Before using this product, please read this manual and other relevant manuals carefully. Pay full attention to safety instructions! In no event will Beijer Electronics be responsible or liable for damages resulting from the use of this product. The images, examples and diagrams in this manual are included for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Beijer Electronics cannot take responsibility or liability for actual use based on the examples and diagrams.
  • Page 7: About The G-Series System

    IP, EtherCAT, PROFINET, CC-Link IE Field, PROFIBUS, CANopen, DeviceNet, CC-Link, MODBUS/Serial etc. • Expansion Module - Expansion module types: Digital IO, Analog IO, and Special modules. • Messaging - The system uses two types of messaging: Service messaging and IO messaging. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 8: Io Process Data Mapping

    Valid parameter data depends on the modules in use. For example, analog modules have settings of either 0-20 mA or 4-20 mA, and temperature modules have settings such as PT100, PT200, and PT500. The documentation for each module provides a description of the parameter data. 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 9: Specifications

    Wiring IO cable max. 2.0 mm (AWG 14) Weight 76 g Dimensions 22 mm x 109 mm x 70 mm 4.3. Communication Specification Adapter type Slave node (PROFINET) Protocol PROFINET Max. expansion modules 10 slots Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 10 • Network error (ERROR) - Green • Expansion IO module status (IOS) - Green/Red 2 LEDs (RJ45 connector): • Link/Active - Yellow • Not used - Green Module location Starter module, left side of the G-Series system 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 11: Wiring Diagram

    5. Wiring Diagram Pin no. Signal description System power, 24 V System power, ground Frame ground Field power, ground Field power, 24 V WARNING Never connect system power to field power! Use separate power supplies. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 12: Led Indicator

    Communication Green Normal communication. Communication ready Flashing Communication identification. green Invalid configuration Flashing DCP communication error (invalid configuration). 6.3. ERROR (Error State) Status LED is Indication No error No error. Connection error Communication connection error. 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 13: Ios (G-Bus Status)

    • Detected invalid expansion module ID. • Too many expansion modules. • Initialization failure. • Overflowed input/output size. • Communication failure. • Changed expansion module configuration. • Mismatch vendor code between adapter and expansion module. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 14: Socket

    RJ-45 Socket 7. RJ-45 Socket For information on network installation, refer to chapter Network Installation. RJ-45 Signal name Description Transmit + Transmit - Receive + Receive - Case Shield 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 15: Dip Switch

    • Any component part (that is, a character string between two dots) of the device name may only be up to 63 characters long. • Names cannot contain any special characters such as umlauts, parentheses, underscores, forward or backward slashes, empty spaces, etc. The dash is the only special character allowed. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 16 ("commissioned"). The default name is “GL9087-address”. Setting the decimal value 63: 63(dec) = 0011 1111(bin) Dip switch 1 = LSB OFF = 0, ON = 1. Dip switches are set to: 1111 110X XX 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 17: Hardware Setup

    Installation position is valid vertical and horizontal. The drawings are illustrative and may be out of proportion. CAUTION NOT following the space requirements may result in damaging the product. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 18: Mount Module To Din Rail

    • GT-5XXX • GT-7XXX GN-9XXX modules have three locking levers, one at the bottom and two on the side. For mounting instructions, refer to Mount GN-9XXX Module. Mount to DIN rail Dismount from DIN rail 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 19 9.2.2. Mount GN-9XXX Module To mount or dismount a network adapter or programmable IO module with the product name GN-9XXX, for example GN-9251 or GN-9371, see the following instructions: Mount to DIN rail Dismount from DIN rail Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 20: Field Power And Data Pins

    Token output port of processor module Serial output Transmitter output port of processor module Serial input Receiver input port of processor module Reserved Reserved for bypass token Field GND Field ground Field VCC Field supply voltage (24 VDC) 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 21: Firmware Upgrade Via Ethernet

    A value of 254(dec) = 00 1111 1110 (bin) counting from the dip switch No.1 as LSB bit. Dip switch 2 to 8 = ON and dip switch 1, 9, and 10 = OFF. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 22 Ping the adapter from a command prompt: ping 192.168.1.100. Access the web page via a standard web browser using the IP address 192.168.1.100 Login with the following credentials: User ID beijer Password beijer Click Choose File. 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 23 13. Power off and on the module. 14. Before utilizing the PROFINET adapter, ensure that the adapter has finished updating. This can be verified through the following methods: • Checking the PROFINET adapter after firmware update, usingPRONETA from Siemens: Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 24 Firmware Upgrade via Ethernet Example 1: M9287 F/W 1.005 = V1.5.0 Example 2: GN-9287 F/W 1.112 = V1.112.0 • Checking the MODBUS TCP adapter via the built-in web server, use 192.168.1.100 (default IP). 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 25 • Checking the firmware version using IO Guide Pro. In IO Guide Pro, go to Tools > Protocol Messenger > Modbus. and select device IP and Protocol MODBUS TCP From the GX-9XXX manual read out the MODBUS address for the Firmware version. Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 26 Firmware Upgrade via Ethernet Send MODBUS message on address (hex): 1003 Response: 010B (hex) = 1.011 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 27: Io Process Image Map

    IO Process Data Mapping. 11.1. Mapping Data into Image Table 11.1.1. Discrete Input Module 4 point input module 8 point input module 16 point input module 32 point input module 11.1.2. Discrete Output Module 4 point output module Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 28: Analog Input Module

    IO Process Image Map 8 point output module 16 point output module 32 point output module 11.1.3. Analog Input Module 4 channel analog input module 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 29: Analog Output Module

    IO Process Image Map 8 channel analog input module 11.1.4. Analog Output Module 4 channel analog output module Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 30: Example Of Input Process Image (Input Register) Map

    11.2. Example of Input Process Image (Input Register) Map Input image data depends on slot position and expansion slot data type. Input process image data is only ordered by expansion slot position. Slot configuration (example) Slot address Module description PROFINET adapter 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 31: Example Of Output Process Image (Output Register) Map

    11.3. Example of Output Process Image (Output Register) Map Output image data depends on slot position and expansion slot data type. Output process image data is only ordered by expansion slot position. Slot configuration (example) Slot address Module description MODBUS/TCP adapter Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 32 Analog output Ch2 low byte (Slot#8) 0x080 Analog output Ch3 high byte (Slot#8) Analog output Ch3 low byte (Slot#8) 0x080 Discrete output low 8 pts (Slot#10) Discrete output 4 pts (Slot#9) 0x080 Discrete output high 8 pts (Slot#10) 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 33: Parameters

    Maximal output length 1440 bytes Physical slots 0..32 Minimal device interval 4 ms Based on portStack DNS compliant name GL9087-xx Supports extended assignment of IP address Fixed in slots Instance field of the object UUID Beijer Electronics, Doc ID: 175229 2025-02...
  • Page 34 Class 1 Supports isochronous mode Number of additional input CRs Number of additional output CRs Number of additional multicast provider CRs Number of multicast consumer CRs Supported send-clock factors (base 31.25 us) 32 64 128 2025-02 Beijer Electronics, Doc ID: 175229...
  • Page 35 Parameters Sub-module Supported Reduction Ratios 1 2 4 8 16 32 64 128 256 512 Port 1: Port 1 Sub-module ident number 0x0003 Sub-slot number 32769 (0x8001) MAU type 100BASETXFD Beijer Electronics, Doc ID: 175229 2025-02...