Model:PT–203 Welding Positioners (With CB-101) Serial number:2203003 ~ and later Date : Mar. 17, 2022 UNITED PROARC CORPORATION No.8 Gungye 2nd Road, Pingjen Industrial Park, Tel No:886 3 4696600 Pingjen Dist., Taoyuan City 324403, Taiwan Fax No:886 3 4694499 http://www.proarc.com.tw E-Mail:...
TABLE OF CONTENTS Introduction Safety precautions ....................i Specification 1.1 Specification ....................1 Operation 2.1 Operation panel ....................2 Troubleshooting 3.1 Troubleshooting ....................4 Part list 4.1 Part List – Machine ..................5 4.2 Part List – Control box ..................6 Circuit 5.1 Circuit diagram ....................
2.1 OPERATION PANEL A. Operation Panel 1. Power On signal. (LED) 2. CW/CCW selection switch.(SW1) 3. Work / Off / Move mode selection switch.(SW2) 4. Normal / Rapid speed selection switch.(SW3) 5. Weld / Test mode selection switch.(SW4) 6. Stop button (STOP) 7.
Page 5
2.1 OPERATION PANEL C. Operation WORK / OFF/MOVE Toggle Switch. (SW2) WORK:Enable the system in “WORK procedure” standby. Press/release the footswitch to start “WORK procedure”. Faceplate rotates according to timer VR1-VR4. OFF:Reset error and stop work procedure. MOVE:Enable the system in “MOVE” procedure standby. Press the footswitch to start the rotation, and release footswitch to stop the rotation.
3.1 TROUBLESHOOTING GUIDE Description Possible Causes / Troubleshoot A. Blown power fuse. B. Broken input power switch. Power indicator LED does not C. Loose cable connection. illuminate. D. LED malfunction, replace switch board. E. Power supply malfunction. A. Damaged motor. B.