R32 UNITARY HEAT PUMP CONDENSER INSTALLATION & OWNER'S MANUAL Models Covered: ACiQ-24-HP32 ACiQ-36-HP32 ACiQ-48-HP32 ACiQ-60-HP32 WARNING: DO NOT destroy or lose this manual. Please read the manual thoroughly. Also, store the manual in a place that allows for easy retrieval and future reference. As a result of continuous product improvement, the specification and design of this unit are subject to change without advanced notice.
Page 3
To Users Thank you for selecting product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below: (1) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience...
Page 4
Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons: Damage the product due to improper use or misuse of the product. Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer.
Contents 1 Safety Precautions ............1 2 Product Introduction ............5 2.1 Operating Range ..............5 2.2 Standard Accessories .............5 2.3 Optional Accessories..............5 3 Installation ................5 3.1 Installation Preparation ............5 3.2 Unit Installation ..............10 3.3 Electrical Installation ............19 3.4 Check after Installation ............
Page 6
7.1 General ................37 7.2 Checks to the Area ............... 37 7.3 Work Procedure ..............37 7.4 General Work Area............... 37 7.5 Checking for Presence of Refrigerant ........37 7.6 Presence of Fire Extinguisher ..........38 7.7 No Ignition Sources .............. 38 7.8 Ventilated Area ..............
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 1 Safety Precautions This product can’t be installed at corrosive, inflammable or explosive environment or the place with special requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service life of the unit, or even cause fire hazard or serious injury.
Page 8
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Appliance filled with flammable magas R32. Before install the appliance, read the installation manual first. Before use the appliance, read the owner’s manual first. Before repair the appliance, read the service manual first. Do not use means to accelerate the defrosting process or to clean,other than those recommended by the manufacturer.
Page 9
DC Inverter U-match Series for R32 Unitary Split Air Conditioner (1) Please install according to this instruction manual. Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only. (2) Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
Page 10
DC Inverter U-match Series for R32 Unitary Split Air Conditioner (1) Do not put a finger or other objects into the air inlet or return air grill. (2) Please adopt safety protection measures before touching the refrigerant pipe; otherwise your hands may be hurt. (3) Please arrange the drain pipe according to the instruction manual.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 2 Product Introduction 2.1 Operating Range — Cooling Heating Outdoor 5°F(-15°C)~129.2°F (54°C) -22°F (-30°C)~75.2°F (24°C) temperature 2.2 Standard Accessories Outdoor unit accessories Name Appearance Q'ty Usage To plug the unused drain Drain plug hole Drainage...
Page 12
(7) Away from any object that may get the air conditioner generating noise. (8) Install the outdoor unit at a place where condensate can be easily drained. 3.1.2 Unit Dimension Unit: inch(mm) Dimensions Model ACIQ-24-HP32 16-13/16 37-13/16 29-3/4 15-9/16 14-9/16...
Page 13
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Unit: inch(mm) Dimensions Model ACIQ-48-HP32 35-7/16 16-1/4 49-5/8 22-7/16 14-7/8 13-3/8 (900) (412) (1260) (570) (378) (340) ACIQ-60-HP32 NOTE: The indoor unit models that can be matched with the outdoor unit can be found on the AHRI website.
Page 14
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 3.1.3 Diagram of Unit Installation Space and Location Diagram of installation space and location for outdoor unit (Notice: for best performance of the outdoor unit, make sure its installation space conforms to the following installation dimensions).
Page 15
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 2) When two or more outdoor units are to be installed side by side. Unit: mm (mm) A,B,C — ≥300 ≥300 ≥1000 — — A,B,C,E — ≥300 ≥300 ≥1000 — ≥1000 —...
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 3) When outdoor units are installed in rows. Unit: mm (mm) ≤ 1/2H b ≥ 250 1/2H < H ≤ H b ≥ 300 > H Prohibited 3.2 Unit Installation (1) The outdoor unit does not have a TXV (thermal expansion valve), please make sure there is a throttling valve (which throttles the unit when it operates in cooling mode and opens fully when it operates in heating mode) in the indoor...
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 3.2.1 Outdoor Unit Installation If the outdoor unit is installed on a solid ground such as concrete, use M10 screw bolts and nuts to secure the unit and make sure the unit stands erect and level.
Page 18
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Do not install the air conditioner in a corrosive environment, otherwise it may shorten the life, or negatively affect the performance of the unit. Installation requirements in snowy areas: 1) Install the air conditioner on a stand which more than 20 in.(500mm) higher than the expected snow fall to prevent it from being covered by snow.
Page 19
Item pipe indoor and outdoor Model length units Liquid pipe Gas pipe feet(m) feet(m) ACIQ-24-HP32 164(50) ACIQ-36-HP32 Φ3/8 Φ3/4 98.4(30) ACIQ-48-HP32 98.4(30) ACIQ-60-HP32 Connection pipe should adopt water-proof insulating material. Its wall thickness should be 0.5-1.0mm and the pipe wall should be able to withstand 6.0MPa. The longer the connection pipe is the worse cooling and heating performance it has.
Page 20
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Do not bend the pipes in an angle more than 90°. If the pipe is repeatedly bent or extended, it will become hard and difficult to be bent or extended. So do not bend or extend the pipe for more than 3 times.
Page 21
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 3.2.2.4.1 Screw Connection Pipe diameter (inch) Tightening torque (N·m) Ф1/4 15-30 Ф3/8 35-40 Ф1/2 45-50 Ф5/8 60-65 Ф3/4 70-75 Ф7/8 80-85 3.2.3 Connection Pipe Vacuum Pumping and Leak Detection 3.2.3.1 Vacuum Pumping (1) Make sure the outlet of vacuum pump is away from fire source and is well-ventilated.
Page 22
DC Inverter U-match Series for R32 Unitary Split Air Conditioner The evacuation duration depends on the unit’s capacity, generally. Model Time(min) ACIQ-24-HP32 ACIQ-36-HP32 ACIQ-48-HP32 ACIQ-60-HP32 And verify if the pressure gauge at the low pressure side of the manifold valve assembly reads -0.1MPa, if not, it indicates there is leak somewhere.
Page 23
Unnecessary Item Standard Additional refrigerant charge pipe Model pipe length amount for extra pipe length ACIQ-24-HP32 30g/m ACIQ-36-HP32 7.5m ≤9.5m ACIQ-48-HP32 20g/m ACIQ-60-HP32 NOTE: Compliance with relevant national gas regulations: Indoor refrigerant joints made on site shall be tested for tightness. The test method shall be leak detection with equipment with a sensitivity of 5g/year or higher at a minimum of 0.25 times the...
Page 24
DC Inverter U-match Series for R32 Unitary Split Air Conditioner If the outdoor unit is above the indoor unit, arrange the pipeline according to the following diagram. 1) Wind the insulating tape from bottom to top. 2) The whole pipeline should be wound together to avoid water returning to the room.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 3.3 Electrical Installation 3.3.1 Requirement and Notice on Electrical Installation The electrical installation for the air conditioner should observe the following requirements: ①. The electrical installation must be conducted by professionals in compliance with local laws and regulations and the instructions in this manual.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner ⑪. This outdoor unit has a heating four-way valve. 3.3.2 Electrical Parameters Maximum Fuse Minimum Power over-current Model capacity circuit ampacity supply protection 208/230V- ACIQ-24-HP32 1Ph-60Hz 208/230V- 27.7 ACIQ-36-HP32 1Ph-60Hz 208/230V- ACIQ-48-HP32 39.9 1Ph-60Hz 208/230V- ACIQ-60-HP32 39.9 1Ph-60Hz NOTE: All wires must go through the tube.
Page 27
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Unit: mm(inch) How to connect the communication wires and power cords. Lead the communication wires and power cords through the insulation tube (as shown in the following figure). (1) Before working, please check whether the units are powered on. (2) Wrong wire connection may burn the electrical components.
Page 28
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Electrical wiring of outdoor units ACIQ-24-HP32, ACIQ-36-HP32 ACIQ-48-HP32, ACIQ-60-HP32 24V mode wiring ACIQ-24-HP32, ACIQ-36-HP32 ACIQ-48-HP32, ACIQ-60-HP32 RS485 mode wiring NOTE: Y means Compressor control signal. B which is energized under the heating mode means 4-way valve control signal.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner RS485 mode wiring is not connected to Y, B, D, L. 24V mode wiring requires all connections. NOTE: When outdoor defrosts, D of outdoor unit will send 24V signal to avoid cold winds.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Check items Possible events due to improper installation stated on the nameplate? burned. Are the wires and pipes installed The unit may fail or its components may get correctly? burned. Has the unit been safely Risk of electric leakage.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner ①. If you use thermostat to turn off the unit and then immediately turn the unit on again, compressor will need 3min to restart. Even if you press “ON/OFF” button on the thermostat, it won’t be started up right away. ②.
Page 32
DC Inverter U-match Series for R32 Unitary Split Air Conditioner The following situations are not operation failures. Problem Time of occurrence Cause If the unit is running under Mist comes from high humidity, the wet air in the air During operation. the room will be quickly conditioner.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.2 Error Code (1) If abnormal things (for example, awful smell) occur, please stop the unit immediately and disconnect power. Then contact authorized service center. If the unit continues to run in abnormal situations, it may get damaged and cause electric shock or fire hazard.
Page 34
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Error code Error Evaporator output tube temperature sensing bag fault Internal jumper cap fault Drive reset protection (fan drive) Internal refrigerant leakage protection Fan communication failure (fan drive) Module temperature too high (fan driven) Drive sensor fault (fan drive) Phase loss protection (fan drive) Bus voltage too high (fan drive)
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.3 Unit Maintenance (1) Only professionals are allowed to carry on daily maintenance. (2) Before contacting any wire, make sure power is cut off. (3) Do not let any inflammable objects near the unit. (4) Do not use organic solvent to clean the air conditioner.
Page 36
DC Inverter U-match Series for R32 Unitary Split Air Conditioner (1) Before cleaning, please make sure the unit is stopped. Cut the circuit breaker and remove the power socket, otherwise, electric shock may occur. (2) Do not wash the air conditioner with water, otherwise fire hazard or electric shock may occur.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.3.5 Components Replacement Components are available in agency or distributors nearby. 4.4 Notice on Maintenance 4.4.1 Information on Servicing The manual shall contain specific information for service personnel who shall be instructed to undertake the following when servicing an appliance that employs a flammable refrigerant.
Page 38
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.4.1.3 Checks to Electrical Devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
Page 39
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.4.3 Repair to Intrinsically Safe Components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use.
Page 40
DC Inverter U-match Series for R32 Unitary Split Air Conditioner practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to reuse of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced: Become familiar with the equipment and its operation.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 4.4.8 Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Examples for such working procedures are: Breaking into the refrigerating circuit; Opening of sealed components; Opening of ventilated enclosures. 6 Transportation, Marking and Storage for Units that Employ Flammable Refrigerants 6.1 General The following information is provided for units that employ FLAMMABLE REFRIGERANTS.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner 6.5 Storage of Equipment / Appliances The storage of the appliance should be in accordance with the applicable regulations or instructions, whichever is more stringent. 6.6 Storage of Packed (Unsold) Equipment Storage package protection should be constructed in such a way that mechanical damage to the equipment inside the package will not cause a leak of the REFRIGERANT CHARGE.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner intrinsically safe. 7.6 Presence of Fire Extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;...
DC Inverter U-match Series for R32 Unitary Split Air Conditioner compliance with national and local codes and standards, such as ASHRAE 15, ASHRAE 15.2, IAPMO Uniform Mechanical Code, ICC International Mechanical Code, or CSA B52. All field joints shall be accessible for inspection prior to being covered or enclosed;...
DC Inverter U-match Series for R32 Unitary Split Air Conditioner re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate percentage of gas (25 % maximum) is confirmed.
DC Inverter U-match Series for R32 Unitary Split Air Conditioner For appliances containing flammable refrigerants, refrigerants purging shall be achieved by breaking the vacuum in the system with oxygen-free nitrogen and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum (optional for A2L).
DC Inverter U-match Series for R32 Unitary Split Air Conditioner Become familiar with the equipment and its operation) Isolate system electrically. Before attempting the procedure, ensure that: 1) Mechanical handling equipment is available, if required, for handling refrigerant cylinders; 2) All personal protective equipment is available and being used correctly; 3) The recovery process is supervised at all times by a competent person;...
Page 50
DC Inverter U-match Series for R32 Unitary Split Air Conditioner refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e.special cylinders for the recovery of refrigerant).
Page 52
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. 66139909769...