Page 1
ACiQ-48-AHB/ACiQ-48-HPB ACiQ-60-AHB/ACiQ-60-HPB Thank you for purchasing a Next Gen Heat Pump system from ACiQ. This system gives you the benefits of a variable speed, inverter driven heat pump condenser, combined with a smart air handler with a variable speed blower.
Option 1 - Wiring Diagram When Using Provided Thermostat (Recommended) ACiQ's provided thermostat will allow the system to operate at maximum efficiency and provide full programmability. Refer to the thermostat user's manual for detailed instructions. See below for quick start wiring guide.
Page 3
Option 2 - Connecting a 3rd Party 24 Volt Thermostat With Communication Wire Connected Any 24 volt thermostat can be selected. Select the appropriate profile from the options listed below to wire thermostat to air handler. S1 & S2 must be connected at the indoor unit and the outdoor unit. Set the system dip switches as shown below.
Page 4
Wiring For 3H and 1C - Two Stage Auxiliary Heat W1/E Grey = Unused Terminal Green = Used Terminal Diagram Grey = White Wire Thermostat Y/Y2 E/AUX Bottom CN10 CN11 Air Handler Data Transfer Circuit Board Wiring For 3H and 2C - With Auxiliary Heat W1/E Grey = Unused Terminal Green = Used Terminal...
Page 5
Function Settings Default AHU DIP Switch Settings Shown Below Thermostat Communication Method SW1-1 RS-485 Communication. Used For Provided ACiQ Thermostat. 24 Volts. Used For Third Party Thermostats. Cold Air Prevention - Defrost SW1-2 Cold Air Prevention Activated - Fan Stops...