UNIT OPERATION:

When the iTECHDCDC60 is connected, all LED indicators will light up, this is normal
operation, the charger is initialising and will take up to 2 minutes to start charging.
The iTECHDCDC60 will go into standby mode if the input voltages are below
the turn off voltage, (please note the iTECHDCDC60 will continue to charge the
auxiliary battery for up to 2 minutes before going into standby), this is indicated by
the charge input and battery type indicator LEDs blinking momentarily at the same
time, once charging voltages have risen above the cut in voltage, it will take up to 2
minutes for the charger to "wake" and begin to charge.
The iTECHDCDC60 will start to charge from solar input if the panel supply voltage
is above 15V and outputting at least 30W (2 Amps).
Input
12V Standard Alternator
24V Standard Alternator
12V Smart Alternator
24V Smart Alternator
6
iTECHDCDC60 OPERATION
Turn on
>13.2V
>26.2V
>12.0V
>24.0V
Turn off
<12.8V
>25.6V
>11.8V
>23.6V