WARNING
Overdue maintenance can lead to re.
WARNING
Always turn the machine OFF and unplug it from the mains
socket before carrying out the work described below. First read
the maintenance instructions at the beginning of this manual.
10.1
Periodic maintenance
The maintenance work indicated with a [1] in the table below may be
carried out by the user; all other work may only be carried out by
quali ed personnel. Before performing maintenance, check status of the
unit(s) in the Air Safety Portal. Then perform a visual check and noise check.
Action
Clean the outside of the machine with a mild detergent.
Clean the inside of the machine and remove the dust/
grease from the lter compartment.
Clean or replace the bag lter and/or compact lter(s).
Check the lter for damage.
10.2
Replacing the lter
Replace the lter:
•
in the event of damage
•
as soon as the extraction capacity becomes inadequate
Because the nature and degree of contamination greatly depend on factors
such as the exact application, humidity level, intensity of use etc., you will
have to determine the necessary replacement frequency based on
experience. Nevertheless, the lter should be checked regularly (every two
weeks to every two months).
WARNING
Contaminated lters often contain dust and dirt particles that
can pose a threat to health when inhaled. Therefore, wear a
proper, approved face mask when cleaning the lter.
10.2.1 Removing the lter
•
Switch the machine o with the main switch ( g. 4).
•
Remove the brackets/latches and open the grille.
•
Take the lter(s) out
10.2.2 Replacing the lters
Bag lter (DFI 30/60 and DFI 8500)
•
•
Compact / HEPA lter (DFI 8500)
11
TROUBLESHOOTING
Problem
Motor does not start
Motor hums, but does not run
Motor stops on its own
Insu cient extraction capacity
Every 6
months
X[
]
1
X[
]
1
X[
]
1
Possible cause
No mains voltage
Main switch defective
Fuse defective
PCB defective
Motor is stuck
Motor defective
Fan dirty
Filters dirty
Suction side air leak
11.1
Malfunctions DFI
If the machine does not work or does not work correctly, consult the
checklist at the bottom of the page to see if you can solve the problem
yourself. If not, seek the assistance of quali ed personnel.
WARNING
Always check rst whether the fault is mechanical or electrical.
Work on and repairs to the electrical system may only be carried
out by trained, authorised service technicians.
Always turn the machine OFF (use the main switch, g. 4) and disconnect the
power supply before carrying out any repairs. First read the repair
instructions at the beginning of this manual.
12
ORDERING SPARE PARTS
Send your order to your supplier and always provide the following
information:
- product name, supply voltage and serial number
(see identi cation plate)
- item number of the part concerned
- part name
- quantity
Remedy
Check the mains voltage
Repair or replace the main switch (by Euromate)
Replace the fuse (by Euromate)
Replace the PCB (by Euromate)
Free/clean the motor (by Euromate)
Repair or replace the motor (by Euromate)
Clean the fan (by Euromate)
Replace the lters. See chapter 8.2.
Check or replace the sealing material.