ICON Truflo TI3M Series Quick Start Manual

Insertion paddle wheel flow meter sensor

Advertisement

Quick Links

Truflo
— TIM | TI3M Series (V1)
®
Insertion Paddle Wheel Flow Meter Sensor
Quick Start Manual
Read the user's manual carefully before starting to use the unit.
Producer reserves the right to implement changes without prior notice.
Valuetesters.com
Find Quality Products Online at:
info@valuetesters.com
1
24-0578 © Icon Process Controls Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Truflo TI3M Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICON Truflo TI3M Series

  • Page 1 Insertion Paddle Wheel Flow Meter Sensor Quick Start Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 2: Safety Information

    Sensor may be under pressure. Take caution to vent system WARNING prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 3: Product Description

    Up to 15x the Wear Resistance Integral Rotor Bushings Reduce Wear and Fatigue Stress 360º Shielded Rotor Design Eliminates Finger Spread No Lost Paddles TI3M 316 SS Thermal Plastic vs. Competitor Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 4: Technical Specifications

    Add Suffix - 6" - 24" TIM-PP-L ‘E’ - EPDM Seals 1" - 4" TIM-PF-S PVDF 6" - 24" TIM-PF-L PVDF Add Suffix - ‘E’ - EPDM Seals Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 5: Display Characteristics

    — TIM | TI3M Series (V1) ® Insertion Paddle Wheel Flow Meter Sensor Display Characteristics LED Display Flow Total Flow Rate M12 Connection Unit | Output Indicators Dimensions (mm) 91.7 91.7 Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 6: Wiring Diagram

    (Refer Pulse Control Programmming, Page 12) Wire Color Description Wire Color Description Brown + 10~30VDC Brown + 10~30VDC White Paddle Pulse Black Pulse Output (OP2) Blue -VDC Blue -VDC Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 7: Installation

    Ensure tab is parallel to flow direction. • Ensure meter is firmly in place Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 8: Installation Positions

    Air Bubbles may be Present Air Bubbles may be Present may be present *Maximum % of solids: 10% with particle size not exceeding 0.5mm cross section or length Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 9: Min/Max Flow Rates

    230.0 | 60.0 7590.0 | 1997.0 PVDF specifications of all components 8" | DN200 315.0 | 82.0 10395.0 | 2735.0 must be considered. | Non-Shock *Optional 316SS PVDF Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 10 (Span : Difference between Upper Range (UPV) & Lower Range (LRV)) Transmitter Offset ▶ Transmitter Offset Factory Default: oSt = 0.000 | Range : 0.000 ~ 9.999 (Offset : Actual Output - Expected Output) Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 11: Totalizer Reset

    CV < SV : Totalizer Output (OP2) OFF Note: Refer Pulse Control Programming (Pg 12) ■ Refer Page 6 for SSR* Wiring *SSR - Solid State Relay Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 12 [SV - Hys] — ▶ Relay OFF: CV > [SV + Hys] or CV < [SV - HyS] — ▶ Relay ON Hys = Hysteresis — Acts like a buffer ± around (OP1) pulse output CV: Current Value (Flow Rate) | SV = Set Value Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 13 Pull out Pull out Insert new paddle in flow meter Paddle Push in pin GENTLY tap Congratulations! approx. 50% Replacement procedure is complete! Ensure holes are aligned Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 14: Installation Fittings

    Glue-On Adapter – CPVC Glue-On Adapter Size Part Number 2”- 4” • 2”-24” Pipe Sizes 6”- 24” PG24 • Easy to Install • Will Accept Signet Flow Meter ® Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 15 316SS TI3 Series ½" SSF005 Flanged Tee Fittings ¾" SSF007 1" SSF010 • Will Accept Signet Type Flow ® 1 ½" SSF015 Meter 2" SSF020 3" SSF030 4" SSF040 Valuetesters.com Find Quality Products Online at: info@valuetesters.com 24-0578 © Icon Process Controls Ltd.
  • Page 16 Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely...