Advertisement

Quick Links

STOP and Read
DO NOT plug in 120V AC outlet
1. Do NOT plug in power cord to power source, use a screw driver to rotate
the fan wheels.
2. If the fan doesn't rotate smoothly, remove the screws and open the front
cover.
3. Reseat the fan wheel bearings and align the motor to fix the issues.
Then replace the front cover back with tighten the screws.
4. Connect the air curtain to a 208V to 240V AC 1 phase power source.
Press the Power Switch and Heater Switches to test it. If the air curtain
works normally, refer to section 3 through 7 to install the air curtain.
Refer to section 10 for technical support.
5. If the fan wheel is broken, contact Awoco (refer to section 10) to get the
fan wheel replacement.
6. After installation, if the air curtain doesn't run, refer to section 6 for
troubleshooting.
PLEASE READ AND SAVE THESE INSTRUCTIONS.
Strongly recommend to test the unit before installation for any
defective or damage during shipment.
USER'S GUIDE
Version: RM-0806S-201907
AIR CURTAINS
Models: RM-0806S Heated
! Test before installing

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RM-0806S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Awoco RM-0806S

  • Page 1 3 through 7 to install the air curtain. Refer to section 10 for technical support. 5. If the fan wheel is broken, contact Awoco (refer to section 10) to get the fan wheel replacement. 6. After installation, if the air curtain doesn’t run, refer to section 6 for troubleshooting.
  • Page 2: Table Of Contents

    WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, READ THE FOLLOWING CAREFULLY before attempting to assemble, install, operate or maintain the product. A. Always disconnect, lock and tag power source before installing or servicing product. Failure to disconnect power source can result in fire, shock or serious injury.
  • Page 3: Installation Planning & Cautions

    2. INSTALLATION PLANNING & CAUTIONS Must observe the following when installing air curtains: Strongly recommend to test the unit before installation for any defective or damage during shipment. 2.1 Please install the unit on a sturdy 2.2 Please install the unit inside the room supporting structure to avoid shaking and and keep a minimum distance of 50mm ensure its security (because the unit running...
  • Page 4: Installation Instructions

    3. INSTALLATION INSTRUCTIONS A. Installing on the concrete wall: 3.1.1 Unscrew the fixing screws to remove 3.1.2 Determine the mounting location with the mounting bracket from the back of the the mounting bracket. Drill holes and insert main body. Zinc-Plated Steel Hex-Nut-Head Sleeve Anchor (not included).
  • Page 5: Technical Parameters

    WARNING: Make sure the air curtain is securely mounted on the wall; otherwise, the air curtain may fall and cause injury to persons. 4. TECHNICAL PARAMETERS Model No. RM-0806S Max Entry Opening 20 Inches Max Air Velocity 787 FPM (4 m/s)
  • Page 6: Wiring Diagram

    Heating element is • The heater is failed. Contact Awoco for heating element replacement. defective. • If the issue you encounter isn’t listed above or you need help with other issues, feel free to contact us at 1-888-412-3428.
  • Page 7: Operating Instructions

    7. OPERATING INSTRUCTIONS • Connect the unit to an appropriate power outlet (Single Phase 208V – 240V AC, 60Hz). • Press the Power Switch to turn on the air curtain in normal mode. The light will be illuminated. • While the air curtain is running in normal mode, press the Heater Switch I or II or both (depending on your need) to change the air curtain to heated mode.
  • Page 8: Warranty

    • Proof of original retail purchase is required to receive warranty service within the limited warranty period. • Repair parts or replacement products will be provided by Awoco, free of charge, on an exchange basis, and will be either new or reconditioned.
  • Page 9: 10. Support And Contact

    • Contact us at 1-888-412-3428, between 9 AM and 5 PM, Monday - Friday, Pacific Time. • Contact us at https://www.awoco.com/contactus. 10. SUPPORT AND CONTACT Contact your local seller for exchange or repair. Visit www.awoco.com for the most updated information. Email to sales@awoco.com or call 1-888-412-3428 for technical support and sales inquiry.