axing OFVS 3217-01 Operation Instructions Manual

Optical fibre amplifier with wavelength-division multiplexing (wdm)

Advertisement

Quick Links

OFVS 3217-01
Optical Fibre Amplifier
with Wavelength-Division Multiplexing (WDM)
Operation instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OFVS 3217-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for axing OFVS 3217-01

  • Page 1 OFVS 3217-01 Optical Fibre Amplifier with Wavelength-Division Multiplexing (WDM) Operation instructions...
  • Page 2: Table Of Contents

    Network Parameters ........................14 3.2.4. Update Firmware ........................14 3.2.5. Active Alarms ..........................15 3.2.6. Modify Password ........................15 Technical data ............................. 16 Page 2 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 3 WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of as residual waste; it must be disposed of separately. 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 3 of 18...
  • Page 4: Product Description

    1 x Optical Fibre Amplifier OFVS-3217-01 2 x AC power cord 1 x Pump laser switching key 1 × Operating instructions 1.4. Accessories Suitable accessories on www.axing.com Page 4 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 5: Block Diagram

    1.5. Block diagram 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 5 of 18...
  • Page 6: Display Elements And Connectors

    11. GPON + RFoF OUT (1310/1490 + 1550 nm) 12. CATV IN (1550 nm) 13. Test port 14. RF test port (F-female) Page 6 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 7 Fan outlets Equipotential bonding connector Power supply unit 1 Power supply unit 2 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 7 of 18...
  • Page 8: Mounting And Installation

    Only turn laser switching key ON, after maintenance is completed.  Set the laser switch key to ON. The laser indicator turns green. Page 8 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 9: Configuration

    Trap2 address NTP Addr1 NTP address1 NTP Addr2 NTP address2 UTC Offset UTC (Universal Time Coordinated) Firmware Ver: V x.xx.x.x Firmware version 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 9 of 18...
  • Page 10 Set NTP server2 address Set UTC Offset Set UTC offset Set Buzzer Enable Set buzzer on or off Restore Factory Restore the factory default configuration Page 10 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 11 Fan invalid Cooling fan is invalid Invalid Power Left Left power supply unit is invalid Right power supply unit is invalid 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 11 of 18...
  • Page 12: Web Interface

     Start your web browser and enter the IP address. Default IP-address 192.168.0.150 The user interface opens.  Enter the Username “admin” and the Password “Ramsen8262”. Page 12 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 13: Display Parameter

     Make the necessary changes in the New Value column.  Then click on Update in the column Click for update.  The new value is applied. 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 13 of 18...
  • Page 14: Network Parameters

     Search for the update file on your PC.  Click on Upload.  After the file has been successfully uploaded, restart the device. Page 14 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 15: Active Alarms

     Enter new username.  Enter new password.  Confirm password.  Click on modify. 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 15 of 18...
  • Page 16: Technical Data

    –5 … 45° C Storage temperature range –30 … 70° C Dimensions (W × H × D) appr. 480 × 88 × 403 mm Page 16 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...
  • Page 17 2024-11-26 | Technical improvements, changes in design, printing- and other errors reserved. | AXING-BA_OFVS-3217-01.pdf | Page 17 of 18...
  • Page 18 Operation instructions | OFVS-3217-01 Page 18 of 18 AXING-BA_OFVS-3217-01.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2024-11-26...