France and Peru only
This unit cannot be powered from IT. supplies. If your supplies are of IT type, this unit
must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary
connection point labelled Neutral, connected directly to earth (ground). †Impédance à la
terre
Power Cord Set
U.S.A. and Canada
Denmark
Switzerland
U.K.
Europe
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are: - No.
18 AWG - not longer than 2 meters, or 16 AWG. - Type
SV or SJ - 3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type with
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
The supply plug must comply with Section 107-2-D1,
Standard DK2-1a or DK2-5a.
The supply plug must comply with SEV/ASE 1011.
The supply plug must comply with BS1363 (3-pin 13 A) and
be fit-ted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked
and be of type HO3VVF3GO.75 (minimum).
The supply plug must comply with CEE7/7 (.SCHUKO.).
The mains cord must be <HAR> or <BASEC> marked
and be of type HO3VVF3GO.75 (minimum).
IEC-320 receptacle.