ERROR CODES- INDOOR UNIT

CODE
OPERATION OR ERROR DESCRIPTION
DISPLAYED
dF
Defrost (not an error code)
FC
Forced cooling (not an error code)
EC07
ODU fan speed out of control
EC51
ODU EEPROM parameter error
EC52
ODU coil temp. sensor (T3) error
EC53
ODU ambient temp. sensor (T4) error
EC54
COMP. discharge temp. sensor (TP) error
EC56
IDU coil outlet temp. sensor (T2B) error
ECC1
Other IDU refrigerant sensor detects leakage (Multi-zone)
EH00
IDU EEPROM malfunction
EH03
IDU fan speed out of control
EH0A
IDU EEPROM parameter error
EH0E
Water-level alarm malfunction
EH12
Main unit or secondary units malfunction
EH3A
External fan DC bus voltage is too low protection
EH3b
External fan DC bus voltage is too high fault
EH60
IDU room temp. sensor (T1) error
EH61
IDU coil temp. sensor (T2) error
EHbA
Communication error between the indoor unit and the external fan module
EHC1
Refrigerant sensor detects leakage
EHC2
Refrigerant sensor is out of range and leakage is detected
EHC3
Refrigerant sensor is out of range
EL01
IDU & ODU communication error
EL0C
System lacks refrigerant
EL11
Communication malfunction between main unit and secondary units
FHCC
Refrigerant sensor error
PC00
ODU IPM module protection
PC01
ODU voltage protection
PC02
Compressor top (or IPM) temp. protection
PC03
Pressure protection (low or high pressure)
PC04
Inverter compressor drive error
PC0L
Low ambient temperature protection
----
IDUs mode conflict (Multi-zone)
40
R
DURASTAR.COM
©2025 Durastar
V1.1 0125