PREFACE
Thank you for purchasing the new UT343E coating thickness gauge. In order to use this product safely and
correctly, please read this manual thoroughly, especially the Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close
to the device, for future reference.
LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from
the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification,
contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of
Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special, indirect,
incidental or subsequent damage or loss caused by any reason or speculation. As some areas or countries do
not allow limitations on implied warranties and incidental or subsequent damage, the above limitation of liability
and stipulation may not apply to you.
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the UT343E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UNI-T UT343E

  • Page 1 PREFACE Thank you for purchasing the new UT343E coating thickness gauge. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
  • Page 2: Table Of Contents

    UT343E User Manual 1. Overview Table of Contents UT343E is an upgraded high-performance coating thickness gauge that can measure coating thickness on both ferrous and non-ferrous matrixes. This device has features of high precision, stable and reliable 1. Overview ------------------------------------------------------------------------------------------- 4 performance and non-destructive measurement, etc.
  • Page 3: Accessories

    UT343E User Manual UT343E User Manual 2. Accessories 4. It can automatically or manually identify the ferrous or non-ferrous matrixes. 5. Automatic voice broadcast of measured values Open the packing box and take out the gauge. Please double check whether the following accessories are 6.
  • Page 4: Safety Instructions

    UT343E User Manual UT343E User Manual 3. Safety Instructions 4. Function Description 1. Initialization self-test is needed for the gauge when it is powered on. When turning on the gauge, please do 4.1 Product Structure not put the sensor close to any metal objects, otherwise the gauge will be unusable.
  • Page 5: Display Interface

    UT343E User Manual UT343E User Manual 4.2 Display Interface 4.2.3 Single Point 4.2.1 Menu Icons Adjust Single point Pass/Fail Mode: Pass/Fail Mode: test mode target value Auto rotate screen µm/mil Units Mode Probe modes Gro p Storage location Measurement modes...
  • Page 6: Multi-Point

    UT343E User Manual UT343E User Manual 5. Operating Instructions 4.2.4 Multi-Point 5.1 Power on/off Long press to turn on/off the gauge. Pass/Fail Mode: Adjust 5.2 Measurement Pass/Fail Mode: target value Note: Keep the probe away from metal objects before turning on the product.
  • Page 7: Menu

    UT343E User Manual UT343E User Manual 5.3.2 Length Unit Note: In the menu, press to select the length unit icon , and then short press to enter its setting 1. Hold the gauge perpendicular to the object to be measured, and lightly press the gauge sensor against the µm/mil...
  • Page 8: Upper Limit

    UT343E User Manual UT343E User Manual 5.3.10 Calibration Mode 5.3.6 Upper Limit In the menu, press to select the calibration mode icon , and then short press to enter its setting In the menu, press to select the upper limit icon , and then short press to enter its setting interface.
  • Page 9: Calculated Values

    UT343E User Manual UT343E User Manual 5.5.2 Multi-Point 5.3.15 Restore Factory Settings a. Press to set the target thickness value, and then press to confirm; In the menu, press to select the restore factory settings icon , and then short press to enter its b.
  • Page 10 UT343E User Manual UT343E User Manual 5.6.1 Zero-Point Calibration f. Pick up the gauge after 2 seconds, the screen displays the value 0.0, as shown in Figure 7, and the gauge automatically returns to the main interface; a. Place the gauge vertically on the uncoated matrix, as shown in Figure 1;...
  • Page 11: Flashlight

    UT343E User Manual UT343E User Manual 6. Performance Indexes 5.6.3 Calibration Verification In the main interface, measure the thickness of the standard coating thickness sheet. The measured value 6.1 Technical Indexes should be within the error range of the nominal value of the standard coating thickness sheet. For example, if...
  • Page 12: General Specifications

    UT343E User Manual UT343E User Manual 6.2 General Specifications When measuring, alarming and pressing buttons, The buzzer must Audio alarm 1. Display: 2” color TFT screen there will be corresponding prompt sounds. be turned on. 2. Refresh rate: 0.5s Limit setting 0~2000μm...