Page 11
NOTE For the EPSON RC+ 7.0 Ver. 7.2.x or later (firmware Ver.7.2.x.x or later), the recommended replacement time for the parts subject to maintenance (Motors, Reduction Gears, Timing Belts, and Ball Screw Spline Unit) can be checked in the [Maintenance] dialog box of the EPSON RC+ 7.0.
Page 12
GX10 Series Service Manual Maintenance Information How to View the Maintenance Information The configured maintenance information can be checked in the EPSON RC+ 7.0 Ver.7.2.x or later. (1) Select the EPSON RC+ 7.0 menu-[Tools]- (3) Select “General” or specify the axis from the tree to [Maintenance] to display the [Controller Tools] dialog display information of the target parts.
Page 13
How to Edit the Maintenance Information The configured maintenance information can be edited in the EPSON RC+ 7.0 Ver.7.2.x or later. When replaced the parts subject to maintenance (Motors, Reduction Gears, Timing Belts, and Ball screw spline) or greased to Joint #3 Ball Screw Spline Unit, please edit the Maintenance Information.
Page 17
NOTE For the EPSON RC+ 7.0 Ver. 7.2.x or later (firmware Ver.7.2.x.x or later), the recommended replacement time for the grease on the Ball Screw Spline Unit can be checked in the [Maintenance] dialog box of the EPSON RC+ 7.0.
Page 172
Adjustment 3.1.2 Calibration Methods Using the calibration wizard EPSON RC+ has a wizard for calibration. The wizard guides you through the calibration process from specifying the joints to be adjusted and the adjustment items (calibration to be performed). To calibrate without using the calibration wizard, refer to 3.1.6.4 Calibration Procedure without Using Calibration...
Page 178
Jog Motion The process to set the jog motion is included in the [Jog & Teach] page of the Robot Manager. Select EPSON RC+ menu - [Tools] - [Robot Manager] and select the [Jog & Teach] tab to use the [Jog & Teach] page.
Page 179
The follow the steps below are calibration using Joint #1. Follow the steps below to calibrate other joints. Start the calibration wizard. Confirm the warning message and click the <Yes> button. I. Select EPSON RC+ menu - [Setup] - [System Configuration]. II. Select [Robots] - [Robot**] - [Calibration].
Page 193
GX10 Series Service Manual Adjustment 3.1.6.4 Calibration Procedure without Using Calibration Wizard NOTE This section indicates the calibration without using the calibration wizard of EPSON RC+. For details of calibration using the calibration wizard, refer to 3.1.6.1 Implementing Calibration using the Wizard.
Page 194
Joint #3: >EncReset 3 Joint #4: >EncReset 3, 4 (3)-5 Reboot the Controller. 0 pulse Select EPSON RC+ menu- [Tools] - [Controller] and click the <Reset Controller> button. NOTE For details on the 0-pulse position, refer to 3.1.5 0-Pulse Position of Each Joint.
Page 195
(4)-1 Execute the following command from the menu - (5)-1 Reboot the Controller. [Tools] - [Command Window]. Select EPSON RC+ menu - [Tools] - [Controller] and >calpls 0,0,0,0 click the <Reset Controller> button. * Manipulator does not move. (5)-2 Click [Control Panel] - <Free All> button to free all...
Page 196
* On RC700D, go on to the step (17). Joint #1: >Calib 1 (7)-1 In EPSON RC+, select [Setup] - [System Joint #2: >Calib 2 Configuration], and then under [Controller] - [Safety Joint #3: >Calib 3 Functions], click [Safety Joint #4: >Calib 3, 4...
Need help?
Do you have a question about the SCARA GX10 Series and is the answer not in the manual?
Questions and answers