  • Page 2: Metric Chart

    PAEC2200C Metric chart 1 Ambient, no heat - PAEC2200CA (IP21) Type Output Airflow* Sound Motor Voltage Amperage Weight power* power motor motor [kW] [dB(A)] [kg] PAEC2210CA-NA 1300 208V~ PAEC2215CA-NA 2150 208V~ PAEC2220CA-NA 2500 208V~ 3 Electrical heat - PAEC2200CE (IP20)
  • Page 3: Imperial Chart

    PAEC2200C Imperial chart 1 Ambient, no heat - PAEC2200CA (IP21) Type Output Airflow* Sound Motor Voltage Amperage Weight power* power motor motor [MBH] [cfm] [dB(A)] [lb] PAEC2210CA-NA 208V~ PAEC2215CA-NA 1250 208V~ PAEC2220CA-NA 1450 208V~ 3 Electrical heat - PAEC3200CE (IP20)
  • Page 4 PAEC2200C F / D / B 1026 / 1536 / 2026 1050 / 1560 / 2050 E / C / A 90,5 min 500 L = 2 m/6.6 ft min 500 min 500 Metric Imperial Product type Metric Imperial [mm]...
  • Page 5 PAEC2200C Metric Imperial [mm] [in] 17.5 0.69 20.5 0.81 25.5 1.00 32.5 1.28 ø17,5 ø17,5 Gland Gland ø32,5 Knock-out ø25,5 Knock-out ø20,5 Gland Knock-out ø17,5 Open the unit...
  • Page 6: Minimum Distance

    PAEC2200C Fig. 3: Open the unit. Minimum distance Fig. 4 30 mm 60 mm 30 mm/1.18 in 60 mm/2.36 in Fig. 5...
  • Page 7 PAEC2200C Mounting with wall brackets PAEC2210Cx 2 pcs G (x3) Ø8 (3x) PAEC2215Cx 2 pcs PAEC2220Cx 3 pcs Ø7 Metric Imperial Ø16 [mm] [in] 10.24 1.46 8.39 2.95 1.38 0.79 0.31 0.28 0.63 Fig. 6: Mounting with wall brackets...
  • Page 8 PAEC2200C Accessories PA34TR15 PAEC2210Cx, PAEC2215Cx, 1 m/3.3 ft PA34TR20 PAEC2220Cx, 1 m/ 3.3 ft PA2P15 PAEC2210Cx, PAEC2215Cx, 1 m/3.3 ft PA2P20 PAEC2220Cx, 1 m/3.3 ft PA2PF15 PAEC2210Cx, PAEC2215Cx PA2PF20 PAEC2220Cx PA2PF PA34TR PA2P...
  • Page 9 PAEC2200C PAEC2200CA 208V1~ 5A x 3 Only 2 m version SENSOR 0 - 10V DOOR PE N 6 5 4 AFTER WATER PE N 6 5 4 White / Tach Red / +10 V Yellow / 0-10 V PWM Blue / GND...
  • Page 10 PAEC2200C PAEC2200CE-208V 0 -10V N H1H2 N F1 F2 F3 Ye llow Blue White Black Blue Ye llow Blue White Black Blue...
  • Page 11 PAEC2200C PAEC2200CE-480V/600V 0 -10V N H1H2 N F1 F2 F3...
  • Page 12 PAEC2200C • Read the safety instructions before performing installation and/or maintenance activities on the unit. • Installation and/or maintenance activities on the unit may only be performed by qualified technical staff. • The unit shall not be installed and used outdoors or in environments that are aggressive, or potentially explosive.
  • Page 13: General Instructions

    (Fig.6C) When the Application bracket is bent once, it must be replaced if PAEC2200C is a compact air curtain with a bent back more than 45 °. recommended installation height of up to 4. Lock the nuts against the brackets. (Fig.6D) 2.2 metres/7.2 feet.
  • Page 14: Maintenance

    PAEC2200C Control options Maintenance Stepless airflow control with door contact/position Since fan motors and other components are limit switch maintenance-free, no maintenance other than cleaning is necessary. The level of cleaning can When the door is closed the fan runs at low vary depending on local conditions.
  • Page 15: Troubleshooting

    PAEC2200C Replacing heating elements/heating Handling of product at end of working package (E) life This product may contain substances necessary 1. Mark and disconnect the cables to the for the functionality of the product but heating elements/package. potentially dangerous for the environment. The 2.
  • Page 16 PAEC2200C Control The air curtain has an integrated control system and can be remotely controlled. 208V~ Black Actuator SD230 (remove the quick Brown connector) Blue PA2DR External on/off Eg time switch. External potential free closure = off Factory setting dip-switches - Unit without heating or with electrical heating Dip-switch 3 is used for PA2DR.
  • Page 17: Functional Test

    PAEC2200C Fan step 1/2/3 ~20 °C Heat step Electric: Half/full power On/off Control panel - Unit with electrical heating Fan step 1/2/3 On/off Control panel - Unit without heating Remote control - on/off, fan steps and heating steps Functional test...