Integration menu.
Parameter
ID
I 02
System integration enabling
I 04
Central heating max wait time
I 05
Integration activation mode
I 07
Activation band
I 09
DHW activation temperature
I 10
System activation temperature
I 11
Outdoor Unit operating hours
Indoor central heating unit
I 12
hours of operation
Indoor D.H.W. unit hours of
I 13
operation
Preheat function enabling
I 15
temperature
118
Magis Combo 12/14/16 V2 I
Description
Using this function, you can enable an alternative
(AL) power source to integrate heating system
central heating
Establishes the maximum amount of time before
activating central heating integration
Establishes how to integrate the heat generator to
the Outdoor Unit, you can choose between "AU"
automatic and "MA" manual
Establishes a temperature range around the
calculated temperature to determine which
generator to switch on
Establishes the outdoor temperature under which
DHW integration is enabled
Establishes the outdoor temperature under which
system integration is enabled
Displays the hours of operation performed by the
Outdoor Unit
Displays the hours of operation by the indoor
central heating unit
Displays the hours of operation by the Indoor Unit
in DHW
If system integration is enabled, this is the
temperature below which the preheat function is
activated
ST.008705/000
Range
Default
OFF - AL
AL
1 - 255 minutes
30
AU - MA
AU
0 ÷ 10 °C
4
-25 ÷ 35°C
2°C
-25 ÷ 35°C
2°C
14 ÷ 25°C
15
Customised
value