MAKING MODERN LIVING POSSIBLE
Commissioning
DHP-AQ
www.heating.danfoss.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the DHP-AQ11 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss DHP-AQ11

  • Page 1 MAKING MODERN LIVING POSSIBLE Commissioning DHP-AQ www.heating.danfoss.com...
  • Page 2 Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC)
  • Page 3: Table Of Contents

    Commissioning ............. . Danfoss Heating Solutions...
  • Page 4: About Documents And Decals

    The following symbols can occur on decals on the different parts of the heat pump. Which symbols are used depends on the heat pump model. 1.2.1 General Warning, danger! Read the documentation provided. Warning, hazardous electrical voltage! Read the documentation provided. VIGFH102 Danfoss Heating Solutions...
  • Page 5 Hot water top sensor Defrost sensor Flow guard 1.2.3 Pipe connections Tap water Heating system Brine system Defrosting tank Expansion tank with safety valve, brine Air bleeding Temperature and pressure relief valve Outdoor unit Water heater Danfoss Heating Solutions VIGFH102...
  • Page 6: Checking Piping And Electrical Installation

    If the amount of water in the heating system is not sufficient, Low Pressure alarms may occur. For DHP-AQ Maxi, also check: Water heater checklist Not OK Bleed valve installed For DHP-AQ Mini, also check: External Water heater checklist Not OK Exchange valve installed (factory installed in DHP-AQ Midi and DHP-AQ Maxi) VIGFH102 Danfoss Heating Solutions...
  • Page 7: Checking The Electrical Installation

    ▪ The sensor must be positioned at least 1 m from openings in the walls that emit hot air. ▪ If the sensor cable is connected through a pipe, the pipe must be sealed so that the sensor is not affected by outgoing air. Danfoss Heating Solutions VIGFH102...
  • Page 8: Filling And Bleeding

    Leave all radiator valves fully open. To bleed the out door unit, remove the lower front hatch and right hand side cover. Fig. 3: Bleed the outdoor unit Fig. 2: Remove front hatch and side cover VIGFH102 Danfoss Heating Solutions...
  • Page 9: Configuration Of Control System

    ▪ Use + or – buttons to select Heat Pump size in kW ▪ Press right arrow (>) to confirm the choice. An asterisk (*) will appear next to the chosen value ▪ Press left arrow (<) several times to navigate to the service menu Danfoss Heating Solutions VIGFH102...
  • Page 10: Factory Setting

    ▪ SYSTEM ▪ OPTIMUM ▪ Press right arrow (>) to enter the optimum function The off symbol ( ) is shown ▪ Press + to activate the optimum function ▪ ON will appear to confirm the setting VIGFH102 Danfoss Heating Solutions...
  • Page 11: Set Hot Water Start Temperature And Activate Hot Water

    In power steps 1 – 3, +4 and +5, the compressor and the electric auxiliary heater can be engaged at the same time. In power steps 4 and 5 only the electric auxiliary heater is engaged. Power steps +4 and +5 can only be engaged for 400V 3-N electric auxiliary heater Danfoss Heating Solutions VIGFH102...
  • Page 12 Electric auxiliary heater for 400V, 3-N. Step 5 is highest setting 5 is highest setting Setting of electric auxiliary heater for 400V, 3-N. Max step 5 in the SERVICE menu: ▪ SERVICE ▪ AUX. HEATER. ▪ MAX STEP ▪ Select max step VIGFH102 Danfoss Heating Solutions...
  • Page 13: Activate Electrical Auxiliary Heater In Dhp-Aq Mini

    NOTE: Too low temperature may result in condensation on the radiators. Default setting: 16°C, range: 5°C — COOLING->STOP Activation of room sensor function for influencing cooling production. ROOM SENSOR NOTE: Room sensor must be installed and activated. Default setting: , range: — ON Danfoss Heating Solutions VIGFH102...
  • Page 14: Distribution Circuits

    When CONSTANT TEMP is selected, distribution circuit con- trols a constant temperature regardless of outdoor tempera- ture. ▪ Press left arrow several times to exit the Service Menu DISTR. CIRCUIT 2 requires expansion card VIGFH102 Danfoss Heating Solutions...
  • Page 15: Manual Test

    0 = four way valve is set for heating FOUR-WAY VALVE 1 = four way valve is set for defrosting/cooling EXPANSION VALVE 0 – 100% for test of electronic expansion valve. 0 = closed solenoid SOLENOID 1 = open solenoid Danfoss Heating Solutions VIGFH102...
  • Page 16 Optimum (variable speed) circulation pump is factory installed in DHP-AQ Midi and DHP-AQ Maxi. The OPTIMUM option is however not activated from factory. The following settings are made in the MANUAL TEST menu. To activate MANUAL TEST, see description above. Use + or – to move up and down in the menu. VIGFH102 Danfoss Heating Solutions...
  • Page 17 6. Stop the compressor by setting the COMPRESSOR value to 0. 7. Stop the circulation pump by setting the CIRC. PUMP value to 0. Fig. 4: The pressure pipe (1) should get hot during operation Danfoss Heating Solutions VIGFH102...
  • Page 18 Shows the actual calculated value for the integral. INTEGRAL Shows the temperature at refrigerant sensor 1. REFR 1 Shows the temperature at refrigerant sensor 2. REFR 2 Displays the temperature on the pool sensor on the condition that pool operation is permitted. POOL VIGFH102 Danfoss Heating Solutions...
  • Page 19 Set the value for MANUAL TEST to 0. 5.10 Insulate the piping When the manual testing is finished, do a final check for leaks and insulate the piping. Make sure that pipes transporting cold water are insulated to prevent condensation damage. Caution Danfoss Heating Solutions VIGFH102...
  • Page 20: Starting Up

    A too low setting may result in high pressure-, or low heat circulation flow alarms. Setting of START FLOW CIRC. value for optimum (variable speed) circulation pump The start flow is maintained for one minute. After one minute, the circulation pump and control system takes over the speed control. VIGFH102 Danfoss Heating Solutions...
  • Page 21 The following settings are made in the INFORMATION MENU. If not already in the INFORMATION MENU, enter the INFORMATION MENU from the default display by pressing (<) arrow. Use + or – to move up and down in the menu. ▪ INFORMATION MENU ▪ OP. DATA ▪ SUPPLY LINE / RETURN LINE Danfoss Heating Solutions VIGFH102...
  • Page 22 Reinstall the lower front hatch and side cover After completed checks and tests the lower front hatch and side cover must be reinstalled on the out door unit. See figure 5. Fig. 5: Reinstall lower front hatch and side cover VIGFH102 Danfoss Heating Solutions...
  • Page 23: Tuning The System

    The control computer shows the value for CURVE by means of a graph in the display. The heat curve can be changed by adjusting the CURVE value. The value for the CURVE indicates which value on the supply temperature is required in relation to the outdoor tempera- ture. For a temporary increase or reduction, adjust the ROOM value instead. Danfoss Heating Solutions VIGFH102...
  • Page 24 3°C for every degree change of the ROOM value. The reason that the curve is adjusted 3°C is that an approximate 3°C increase in supply temperature is usually needed to increase the indoor temperature 1°C. VIGFH102 Danfoss Heating Solutions...
  • Page 25 The factory set value for activating heat stop is an outdoor temperature of 17°C. If the heat stop function is active, the outdoor tempera- ture must drop 3°C below the heat stop setting, before the heat stop is deactivated and heat production starts again. Danfoss Heating Solutions VIGFH102...
  • Page 26: Installation Protocol And Customer Info

    The serial number must always be given for warranty matters. The serial number is on the type plate, which is attached to the heat pump and control unit. VIGFH102 Danfoss Heating Solutions...
  • Page 27: Important Information/Safety Regulation

    Alternatively the maximum hot water temperature must be reduced in the Service menu. Danfoss SP (1-phase) heat pumps have a factory installed safety valve for temperature and pressure, (10 bar Warning 90-95°C), in accordance with the requirements in Great Britain.
  • Page 28 Refrigerant vapour is heavier than air and, in enclosed spaces below the level of a door for example, and in the event of leakage, concen- trations can arise with a resultant risk of suffocation due to a lack of oxygen. VIGFH102 Danfoss Heating Solutions...
  • Page 29: Electrical Connection

    Draining and refilling must only be carried out using new refrigerant (for the amount and type of refrigerant see manufacturer’s plate) through the service valves. All warranties from Danfoss are void if, when filling with refrigerant other than Danfoss A/S specified refriger- Caution ant, if there has not been written notification that the new refrigerant is an approved replacement refrigerant together with other remedies.
  • Page 30: Water Quality

    If the installation is only to be driven by the immersion heater during the installation, ensure that the heating Caution system is filled and the brine pump and compressor cannot be started. This is carried out by setting the oper- ating mode to AUX. HEATER. VIGFH102 Danfoss Heating Solutions...
  • Page 31 Commissioning Danfoss Heating Solutions VIGFH102...
  • Page 32 Internet: www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.