Page 1
Instruction Manual TSG 131A Multiformat Signal Generator S/N B040000 and Above 071-0499-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
Page 2
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. Printed in the U.S.A. Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077...
Page 17
Contacting Tektronix Product For questions about using Tektronix measurement products, call support toll free in North America: 1-800-833–9200 6:00 a.m. – 5:00 p.m. Pacific time Or contact us by e-mail: tm_app_supp@tek.com For product support outside of North America, contact your local Tektronix distributor or sales office.
Page 19
General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only qualified personnel should perform service procedures. To Avoid Fire or Use Proper Power Cord.
Page 20
General Safety Summary Symbols and Terms Terms in this Manual. These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Page 21
Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
Page 55
Table 3–8 Video Comp Sync (Opts. 2, 3, & 4) CHARACTERISTICS PERFORMANCE SUPPLEMENTAL PER. REQUIREMENT INFORMATION CHECK STEP # Duration Horizontal Sync 4.7 s 100 ns Vertical Serrations 4.7 s 100 ns Equalizing Pulses 2.35 s 100 ns Amplitude Opt 2 & 3 0.4 V Jumper Selectable to –4 V.
Page 56
TSG 131A – Specifications Table 3–10. Power Supply Specifications CHARACTERISTICS PERFORMANCE SUPPLEMENTAL REQUIREMENT INFORMATION Supply Accuracy +5 V +5 V 250 mV –5.2 V –5.2 V +300 mV to –500 mV –12 V –12 V 600 mV +12 V +12 V 600 mV Power Limit 18 Watts...
Page 58
Table 3–13: Certifications and compliances Category Standards or description EC Declaration of Conformity – Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Union: EN 50081-1 Emissions: EN 55022 Class B Radiated and Conducted Emissions EN 50082-1 Immunity:...
Page 59
Table 3–13: Certifications and compliances (cont.) Category Standards or description Pollution Degree A measure of the contaminates that could occur in the environment around and within a product. Typically the internal environment inside a product is considered to be the same as the external.
Page 200
65. Rise & Fall Times 250 ns 50 nsa. Opts 2 and 3 (If set for Comp Sync) and Opt 4 a. Connect the equipment as shown in Fig. 4–7. b. Display CH 2 on the oscilloscope. c. Use the variable gain to normalize the signal to 1000 mV.
Page 232
TSG 131A. Use this list to identify and order replacement parts. There is a separate Replaceable Electrical Parts list for each instrument. Parts Ordering Information Replacement parts are available from or through your local Tektronix, Inc., Field Office or representative. Changes to Tektronix instruments are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest circuit improvements.
Page 233
Chassis-mounted parts and cable assemblies have no assembly number prefix and are located at the end of the electrical parts list. Tektronix Part No. Indicates part number to be used when ordering replacement part from (Column 2) Tektronix.
Page 234
2015 SECOND STREET BERKELEY CA 94170 C/O PANEL COMPONENTS CORP S4307 SCHAFFNER ELECTRONIK AG LUTERBACH SWITZERLAND TK1345 ZMAN & ASSOCIATES TK1450 TOKYO COSMOS ELECTRIC CO LTD 2–268 SOBUDAI ZAWA KANAGAWA 228 JAPAN 8–3 TSG 131A Signal Generator (B040000 & up)
Page 252
Component Locator Diagrams Other standards used in the preparation of diagrams by Tektronix, Inc., include the following: The schematic diagram and circuit board component location illustrations have grids marked on them. The component lookup tables refer to these grids to help you locate a component.
Page 268
TSG 131A Instruction Manual (B040000 and Above) 9–17...
Page 269
The schematic diagram has an alpha-numeric grid to assist in locating parts within that diagram. Assemblies A3 and A4. A3 Top BNC J401 J404 J405 W405 A4 Bottom BNC J501 J505 W505 9–18 TSG 131A Instruction Manual (B040000 and Above)
Page 270
TSG 131A Instruction Manual (B040000 and Above) 9–19...
Page 271
U42A FL1* R114 U42B FL2* R115 FL3* R116 FL4* R117 W128 R118 W129 R119 W130 R120 R121 R122 R123 * Check parts list for starting/ending S/N. ∆ Not used on TSG 111. 9–20 TSG 131A Instruction Manual (B040000 and Above)
Page 272
TSG 131A Instruction Manual (B040000 and Above) 9–21...
Page 278
TSG 131A. Use this list to identify and order replacement parts. There is a separate Replaceable Mechanical Parts list for each instrument. Parts Ordering Information Replacement parts are available from or through your local Tektronix, Inc., Field Office or representative. Changes to Tektronix instruments are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest circuit improvements.
Page 279
Figure & Index No. Items in this section are referenced by figure and index numbers to the illustra- (Column 1) tions. Tektronix Part No. Indicates part number to be used when ordering replacement part from (Column 2) Tektronix. Serial No.
Page 280
ST PAUL MN 55144–0001 INDUSTRIAL SPECIALTIES DIV 78189 ILLINOIS TOOL WORKS INC ST CHARLES ROAD ELGIN IL 60120 SHAKEPROOF DIV 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR BEAVERTON OR 97077–0001 PO BOX 500 93907 TEXTRON INC 600 18TH AVE ROCKFORD IL 61108–5181...
Need help?
Do you have a question about the B040000 and is the answer not in the manual?
Questions and answers