GENERAL INFORMATION
CAUTION: The pump is designed for air only. Do not allow corrosive gases or particulate
material to enter the compressor. Water vapor, oil-based contaminants or other
liquids must be filtered out.
CAUTION: Ambient temperature should not exceed 40C (104F). For operation at higher
temperatures, please consult the factory. Keep out of direct sunlight when ever
possible.
CAUTION: To avoid risk of electrocution, do not use this product in an area where it could
become submerged in water or other liquids.
CAUTION: Do not block the flow of cooling air around the compressor in any way. The life
of the pump may be reduced or malfunction could occur if hazard is ignored.
GROUNDING INSTRUCTIONS
FOR ALL GROUNDED, CORD-CONNECTED PRODUCTS
This product should be grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current. The compressor
is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug
must be plugged into an outlet that is properly installed and grounded in accordance with all
local codes and ordinances.
! DANGER:
Check with a qualified electrician if the grounding instructions are not completely understood,
or if in doubt as to whether the product is properly grounded. Do not modify the plug provided;
if it will not fit the outlet, have the proper outlet installed by a qualified electrician. This product
is for use on a nominal 120 volt circuit
Grounded
3
Improper installation of the grounding plug can result in a risk of electric
shock. If repair or replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade terminal. The wire with
insulation having an outer surface that is green, with or without yellow
stripes, is the grounding wire.
Grounded
Outlet
Pin
Grounded
Outlet Box
Cover
Need help?
Do you have a question about the SP10 and is the answer not in the manual?