Summary of Contents for barbas EVO-7 50-40

  • Page 1 User manual EVO-7 50-40 EVO-7 50-40 Opti-Air This product is not suitable for primary heating purposes Serial number: Production date:...
  • Page 2 Barbas Bellfires BV.This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in thecontents thereof.
  • Page 3 6.3.2 Reload with fuel.......................19 6.3.3 Control the burn process ....................19 6.3.4 General firing tips......................21 Firing the appliance with the optional Barbas Opti-Air system...........21 6.4.1 Installation of the Opti-Air app ..................21 6.4.2 First load and ignition with Opti-Air................. 21 6.4.3 Reload with fuel.......................23 6.4.4 General firing tips......................
  • Page 4 7.3.1 Access to inside of door ....................26 Opti-Air system ......................... 27 Troubleshooting..................28 Troubleshooting......................... 28 Troubleshooting on Opti-Air system...................29 Information on disposal of the appliance ..........30 Technical data ..................31 Product information according regulation (EU) 2015/1185....32 Warranty Terms..................34 EVO-7 50-40...
  • Page 5 Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
  • Page 6 Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
  • Page 7 About this document About this document This document shows the necessary information to do these tasks on the EVO-7 50-40: • Operate the appliance • Do basic maintenance This document refers to the EVO-7 50-40 as 'the appliance'. This document is an essential part of your appliance.Read it carefully before you do work on the appliance.
  • Page 8 This helps you to achieve an efficient and clean combustion at all times. You can operate the Opti-Air device with the Barbas Opti-Air app on your mobile device. With this app you have the possibility to choose different combustion levels or the possibility to control the room temperature.
  • Page 9 • With the Barbas Opti-Air system it is not possible to manually control the amount of combustion air into the appliance. 3.2.2 Overview of the Barbas Opti-Air app...
  • Page 10 Combustion levels in combination with a convection ventilator The Opti-Air system in combination with a convection ventilator has 5 combustion levels to choose from. Each combustion level is a combination of pre-defined thermal output and pre-defined ventilator speed. EVO-7 50-40...
  • Page 11 50% of maximum speed Nominal Maximum Maximum Maximum The Barbas Opti-Air app indicates when the Burning or Refill combustion mode starts. This is dependent on the gas temperature and the chosen combustion level. Combustion level Burning Refill Gas temperature must be higher...
  • Page 12 The appliance was not reloaded with fuel within 45 mi- Cooling down nutes after Refill notice . Cooling down mode is active. Note: With the Barbas Opti-Air system it is not possible to manually control the amount of combustion air into the appliance. Intended use The appliance is intended for indoor use to heat the room wherein it is installed.
  • Page 13 Note: • Do inspect and clean the appliance, the chimney and the external combustion air supply by a Barbas dealer minimum every year. • Do not use the appliance continuously. The intended use is as intermittent appliance.
  • Page 14 Safety • Dispose of an obsolete appliance according to instructions of the authorities or the fitter. • Obey the local regulations. EVO-7 50-40...
  • Page 15 Approximately 30 cm Approximately 30 cm Outline Approximately 30 cm Approximately 30 cm The above listed amount burns for approximately 45 minutes. This time can be different, dependent on the chimney draught and the position of the combustion air valve. EVO-7 50-40...
  • Page 16 Use wood logs or wood briquettes (without binder) with a length of approximately 30 cm and an outline of approximately 30 cm. The above listed amount burns for approximately 45 minutes. This time can be different, dependent on the chimney draught and the position of the combustion air valve. EVO-7 50-40...
  • Page 17 Make sure that all package material, stickers, etc, has been removed from the vicinity of the appliance after installation. 6.4.1 If applicable, download and install the Barbas Opti-Air app. Refer to section detailed instructions. First use of the appliance Caution: •...
  • Page 18 Put a layer of small wood pieces and a firestarter cube on top of the wood logs. Put some kindling wood above the firestarter cubes. Light the firestarter cubes with a lighter or a match. Close the door of the appliance. EVO-7 50-40...
  • Page 19 Note: If the appliance has the Opti-Air option refer to section instructions on the control of the burn process. Control the burn process with the control lever. This lever controls the amount of primary combustion air and both the secondary combustion air and airwash amount. EVO-7 50-40...
  • Page 20 Never close the air inlets when the fuel is burning. Always keep the secondary air inlet and air wash inlet open by setting the control lever somewhere in-between the center position and the far left position. EVO-7 50-40...
  • Page 21 If the appliance has the optional Opti-Air system, the appliance automatically controls the amount of combustion air. With the Barbas Opti-Air app for Android and iOS it is possible to select from 5 different combustion levels or to select room temperature control.
  • Page 22 Open the door of the appliance. Put 6 wood logs crosswise on the floor of the combustion chamber. Put a layer of small wood pieces and 2 firestarter cubes on top of the wood logs. Put some kindling wood above the firestarter cubes. EVO-7 50-40...
  • Page 23 Make sure the door of the appliance is closed when in use. Only open the door for ignition and to refuel. • Do not remove all the ashes. An ash layer in the combustion chamber forms an insulating layer, that helps the fuel to ignite easy. EVO-7 50-40...
  • Page 24 OFF position 6.5.2 Convection ventilator with Opti-Air system 3.2.3 The ventilator speed is dependent on the chosen combustion level. Refer to section for more information. Note: The ventilation set-up function in the Barbas Opti-Air app is not active. EVO-7 50-40...
  • Page 25 Make sure that the glass is dry. Water droplets can leave a mark on the glass. Note: Damaged or broken glass must be replaced before the appliance can be used again. EVO-7 50-40...
  • Page 26 Rotate the door forward. The inside of the door and the glass is now accessible for inspection and cleaning. To close the door and frame do steps 2 to 4 in reverse order. Make sure the door lock is is locked. EVO-7 50-40...
  • Page 27 Replace the 9 V battery and close the battery holder. Put the battery holder and ventilation air inlet grate back. Post requirements • Change the 9 V back-up battery every year. EVO-7 50-40...
  • Page 28 The chimney draught is too Contact your installer. high • Do the recommended ignition Excessive smoke escapes procedure. Refer to section The chimney draught is too when the door of the combus- 6.3.1 tion chamber is open • Contact your installer. EVO-7 50-40...
  • Page 29 The amount of fuel is insuffi- Use the recommended amount of change to Burning after Refill. cient. fuel. Refer to section 5.2.2 6.4.3 section Notification Sensor error in the Defect of one of the sen- Contact your dealer. app. sors. EVO-7 50-40...
  • Page 30 Insulating plates used Calcium silicate Remove from appli- Dispose as building for the fireplace ance . construction waste (stone) Gaskets Glass fibre cord or Remove from appli- Dispose as glass fibre plates ance and components (non-flammable waste) EVO-7 50-40...
  • Page 31 Technical data Technical data Name Barbas Barbas Model EVO-7 50-40 EVO-7 50-40 Opti-Air EN 13229:2001-A2:2004 EN 13229:2001-A2:2004 EN 16510-1 annex D, E, F EN 16510-1 annex D, E, F Tested in accordance with BS 3841-2:1994 BS 3841-2:1994 Energy efficiency index (ac-...
  • Page 32 Product information according regulation (EU) 2015/1185 Product information according regulation (EU) 2015/1185 Model identifier Cuatro-7 60-60 Equivalent models Evo-7 50-40 Indirect heating function Direct heat output 8.3 kW Indirect heat output - kW Emissions at nominal heat Emissions at minimum heat...
  • Page 33 Product information according regulation (EU) 2015/1185 Model identifier Cuatro-7 60-60 Opti-Air Equivalent models Evo-7 50-40 Opti-Air Indirect heating function Direct heat output 9.5 kW Indirect heat output - kW Emissions at nominal heat Emissions at minimum heat output (*) output (*)(**)
  • Page 34 Warranty Terms Warranty Terms To make a claim under the warranty, it is important to register the Barbas appliance after pur- chase via www.barbasbellfires.com. Barbas Bellfires Warranty Terms Barbas Bellfires B.V. guarantees the quality of the supplied Barbas appliance and the quality of the materials used.
  • Page 35 Article 5: Warranty period This warranty will only be granted during the warranty period. The body of the Barbas appliance is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase. For other parts of the Barbas appliance, a similar warranty applies from the moment of purchase for a period of two years.
  • Page 36 Your Barbas dealer 19.06.2023 - 353266 - 292-002...