Page 2
CASPR. Your COMPACT unit can provide years of trouble-free disinfection and protection. Some parts of your CASPR COMPACT will need to be replaced periodically. Replacement parts can be purchased from your authorized distributor or directly from CASPR Technologies at www.casprtech.com...
Page 3
Start here… Initial set up 1. For your most ideal effectiveness, place CASPR COMPACT unit 4-7 feet off the ground ensuring there is a minimum of 6 inches behind the unit to allow for proper airflow. 2. Face the unit towards the center of the area you are protecting.
Page 4
Mode regardless of what mode is displayed on screen and can always be used in occupied spaces. Any questions please contact your distributor or the CASPR company directly. 10. AWAY MODE: The Away Mode was designed to produce a small amount of ozone and to be used when you are AWAY from the space.
Page 5
Note: When the purification plate has been removed your unit will remain in Standard PCO/NCC Mode regardless of what mode is displayed on screen and can always be used in occupied spaces. Any questions please contact your distributor or the CASPR company directly.
Page 6
Additional Information • Each CASPR COMPACT can effectively treat 1,500 sq feet of space, if there is air circulation in the space. Ensure doors remain open in rooms you are trying to disinfect. • Best practice is to face your COMPACT unit towards the largest open space you are disinfecting so it can efficiently process and circulate the air in the area.
Page 7
Removing and Cleaning the Filter Assembly 1. Turn off the unit by pressing the Power button. 2. Unplug the unit from the power source and then remove the power cord from the back of the unit. 3. Unscrew and remove the Rear Cover screw located above the Power Cord Port on the rear of the unit.
Page 8
Reattaching the Filter 1. Gently lay the filter back onto the machine with the diamond pattern facing the rear of the unit and the honeycomb pattern facing the front of the unit. 2. Replace the Rear Cover by sliding it from the top of the unit towards the bottom to secure the filter in place.
Page 9
7. Un plug the cell power cable. 8. Pull the NCC cell away from the unit and attach the new NCC cell. 9. Reinsert the two screws to secure the new cells. assembly.
Page 10
Do not overtighten. You are good to go! Removing and Cleaning the Front Grille 1. Locate the Front Grille Screw on the front of the machine above the CASPR logo. 2. Using your screwdriver, carefully remove the Front Grille Screw and place the screw where you will easily find it later.
Page 11
4. Verify the Power Button has been activated on the Control Panel. 5. If the Power Button on the Control Panel fails, try using the Power Button on your Remote Control. If the Control Panel fails, contact your distributor or CASPR Technologies (www.casprtech.com).
Page 12
Cell Power Connector snap into place, securing it to the Cell Power Connector Outlet. 2) If the Cell still fails to operate, it needs to be replaced. Contact your distributor or CASPR (www.casprtech.com).
Page 16
Product or Components defects, including but not limited to downtime costs, loss of use, loss of revenue, and/or loss of profits. SALES THROUGH DISTRIBUTOR OR RESELLER To the extent the Product is purchased by Buyer from an authorized CASPR distributor or reseller, this Express Limited Warranty passes through to Buyer. FOR U.S. APPLICATION ONLY Product warranties are governed by state and federal laws and may vary from state to state.
Page 17
IONIZATION NEEDLE 24 to 30 KV, 20-30 Khz Ion Generation Pulsator 6 KV DC Needle Ion Generator CASPR Technologies declines all responsibility for all damages arising from improper use of the unit or in case of tampering with the unit.
Need help?
Do you have a question about the Compact and is the answer not in the manual?
Questions and answers