Page 1
OPERATION & SERVICE MANUAL Model: 02-7812C0110 5 Ton Single Stage Jack 04/2014 – Rev. 02 Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558 Email: sales@tronair.com...
Page 2
REVISION DATE TEXT AFFECTED 09/2008 Original Release 04/2014 Modified 5.1 Jack Instructions, Parts List...
Page 3
Model: 02-7812C0110 5 Ton Single Stage Jack TABLE OF CONTENTS PAGE DESCRIPTION ................................1 USAGE ..................................1 3.0. SPECIFICATIONS ................................. 1 ASSEMBLY INSTRUCTIONS ............................1 GENERAL INFORMATION ............................1 PRE-USE CHECKS ..............................1 OPERATING INSTRUCTIONS ............................1 JACK INSTRUCTIONS .............................. 2 MAINTENANCE ................................
Page 4
5 Ton Single Stage Jack This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur.
Page 5
Replace ram protection ring if it does not have a radius groove for the locking pin. Load test jacks annually. Only order replacement parts from Tronair. Failure to comply could result in premature failure below certified weight and could cause serious injury including death.
Page 6
Model: 02-7812C0110 5 Ton Single Stage Jack JACK INSTRUCTIONS (continued) Incorrect Pin Placements Washer In Ball Lock In Washer On Top Of Locking Pin Not In Ram Protection Ring Ram Protection Ring Ram Protection Ring Ram Protection Ring and top Locking Pin...
Page 7
Model: 02-7812C0110 5 Ton Single Stage Jack JACK INSTRUCTIONS (continued) To Lower Aircraft: Lower all jacks simultaneously. If ram locking nut(s) is tight, raise jack slightly to release nut(s). Loosen pump release valve slightly to slowly lower aircraft. Raise locking nut(s), as jack ram(s) lower.
Page 8
Model: 02-7812C0110 5 Ton Single Stage Jack TROUBLE SHOOTING TROUBLE PROBABLE CAUSE ACTION Remove piston and pump body. Inspect for Fluid leakage at pump piston Damaged backup ring, o-ring, piston or damage. Replace defective part(s). Replace or pump body pump body...
Page 9
GUARANTEES/LIMITATION OF LIABILITY Tronair products are warranted to be free of manufacturing or material defects for a period of one year after shipment to the original customer. This is solely limited to the repair or replacement of defective components. This warranty does not cover the...
Page 10
Model: 02-7812C0110 5 Ton Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description N-2788-02-S-B Elbow, 90o Male TF-1043-03*15.0 Assembly, Hose, 15" long N-2001-05-S-B Elbow, Straight Thread...
Page 11
Model: 02-7812C0110 5 Ton Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description K-1061-02 Kit, Reservoir Replacement; consists of: N-2653-01-S-B Elbow, 90 Male, ¼ Hose x SAE #4 TF-1047-01*09.0...
Page 12
Model: 02-7812C0110 5 Ton Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description HJ-532-01 Pad, Jack HJ-526-05 Extension HJ-536 Ring, Protection G-1151-106205 Screw, Socket Head Cap, 5/16-18 x 5/8" long...
Page 19
Model: HC-1948 1950 psi Hand Pump Parts List With Illustrations 10/2002 – Rev. OR Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558 Email: sales@tronair.com...
Page 21
1950 Hand Pump This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., its suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur. Only Tronair OEM replacement parts shall be used.
Page 22
HC-1948 1950 Hand Pump Parts List Illustrations WARNING! Item 10 (H-2683) is a preset relief valve. Do not disassemble this valve. Replacement parts are available as a preset relief valve assembly. 10/2002 | Rev. OR Page | 2...
Page 23
APPENDIX III Safety Data Sheet (SDS) MIL-PRF-5606 Hydraulic Fluid...
Page 37
DECLARATION of CONFORMITY The design, development and manufacture is in accordance with European Community guidelines Tripod Jack 02-7812C0110 Relevant provisions complied with by the machinery: 2006/42/EC Relevant standards complied with by the machinery: EN ISO 12100-1 Identification of person empowered to sign on behalf of the Manufacturer: Quality Assurance Representative Tronair, Inc.